cs.LGNov 13, 2026

SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series

Authors: Hannes Ill, Dimitrios Proios, Leo Anthony Celi, Peter J. Schüffler

Organizations: Laboratory for Computational Physiology, Massachusetts Institute of Technology, USA · Institute of Pathology, Technical University of Munich, TUM School of Medicine and Health, Munich, Germany · Department of Radiology and Medical Informatics, Faculty of Medicine, University of Geneva, Geneva, Switzerland · Division of Pulmonary, Critical Care and Sleep Medicine, Beth Israel Deaconess Medical Center, USA · 

Abstract

Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.

Figures & tables

Appendix figures & tables25 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 1, 2026

LeNEPA: No-Augmentation Next-Latent Prediction for Time-Series Representation Learning

Time series are central to modern data mining applications, from industrial telemetry and server metrics to finance and physiology, yet time-series self-supervised learning often depends on view and augmentation choices that encode domain-specific invariances. We study how an SSL recipe behaves when its method-specific configuration is reused unchanged after the pretraining signal family changes, framing this as a fixed-recipe stress test rather than a comparison against optimally tuned methods. We introduce Latent Euclidean Next-Embedding Prediction Architecture (LeNEPA), a no-augmentation next-latent-token objective with a causal backbone. LeNEPA replaces the stop-gradient/EMA stabilization used by vanilla NEPA with SIGReg-based isotropy regularization and computes the predictive loss in a lightweight projected space that is discarded for evaluation. We compare LeNEPA with an ECG-tuned JEPA recipe under a fixed-horizon frozen-probe protocol on PTB-XL and Diag, a synthetic diagnostic corpus generated with Aionoscope. Both methods are retrained independently on each dataset while keeping their method-specific recipes unchanged. In this protocol, the ECG-tuned JEPA recipe is strong in-domain on PTB-XL but weaker when reused unchanged on Diag, whereas LeNEPA preserves useful frozen-probe gains on both datasets. Learning curves suggest faster early representation acquisition: LeNEPA reaches 80% of its final AUROC/AUPRC gain after 2--5k updates, compared with 5--10k updates for the faster JEPA readout. As a separate external frozen-encoder check, a CauKer-pretrained LeNEPA variant reaches 77.65% mean UCR-128 Random-Forest accuracy in a single-seed, best-checkpoint run, within 1.16 points of Mantis and within 0.24 points of MOMENT (77.89%). Overall, the results support no-augmentation latent prediction as a useful candidate recipe for low-retuning time-series SSL.
Jul 18, 2026

A Framework for Early Sepsis Prediction via Self-Supervised (JEPA) and Federated Representation Learning

Early sepsis prediction from electronic health records is challenged by irregular sampling, high missingness, and class imbalance. We systematically compare four modeling paradigms -- self-supervised Joint Embedding Predictive Architecture (JEPA) via masked latent prediction, self-supervised VICReg (variance-invariance-covariance regularization) with two-view augmentation, semi-supervised fine-tuning of a VICReg-pretrained encoder, and supervised Temporal Convolutional Network (TCN) -- alongside raw-feature baselines. All models share a common preprocessing pipeline of hourly binning with forward-fill imputation applied to 7 biomarkers selected via sparsity analysis from the MIMIC-III dataset. Our best model (JEPA + XGBoost + mean pooling) achieves AUPRC 0.636 at the time of onset (H0), approaching the SupMix benchmark (0.667) while using 83% fewer biomarkers. The Tier 1 pipeline -- VICReg pretraining followed by semi-supervised fine-tuning and XGBoost -- achieves AUPRC 0.510 at H0, a 3.1×\times improvement over the raw-feature baseline (0.165) and a 7.6% improvement over the end-to-end supervised TCN (0.474). Crucially, the fine-tuned VICReg encoder exhibits the most temporally persistent representations, degrading only 16.8% from H0 to H10 compared to 47.5% for supervised TCN and 65.3% for JEPA, demonstrating that self-supervised pretraining with task-aware fine-tuning yields features that are both sharp near onset and robust across prediction horizons.
Apr 13, 2026

Sparse Autoencoder Decomposition of Clinical Sequence Model Representations: Feature Complexity, Task Specialisation, and Mortality Prediction

Sparse autoencoders (SAEs) have been applied to large language models and protein language models, but not systematically to electronic health record (EHR) foundation models. We train TopK SAEs on FlatASCEND, a 14.5-million-parameter autoregressive clinical sequence model, at all 10 residual stream extraction points on INSPECT (outpatient) and MIMIC-IV (ICU). SAE decomposition reveals progressive abstraction across transformer depth: layer-0 features are near-perfect token detectors (45.7% singleton), while layer-6 features span approximately 30 token types across multiple clinical categories (0.5% singleton). Under full-sequence simple linear probes, SAE features outperform dense representations for discrete event prediction (mortality) while dense representations outperform for continuous magnitude prediction (length of stay) - a probe-level representational phenomenon that does not extend to clinically relevant leakage-safe windows, where dense representations match or exceed SAE features across all tested settings (eICU-CRD 48-hour AUC: SAE 0.871 versus dense 0.880; base model zero-shot, SAE dictionaries trained on eICU activations; MIMIC-IV: 0.836 versus 0.914; INSPECT 1-year/3-year: 0.697 versus 0.800). A delta-mode intervention method reduces SAE perturbation noise by 86x, enabling cleaner feature-level experiments, though the resulting perturbation effects are larger than random controls in 3 of 4 conditions but not formally significant. Feature reproducibility across random seeds is 21%, and individual features should be interpreted as illustrative rather than stable.