cs.CVNov 16, 2026

Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort

Authors: Kabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary, Amal Saleh Nour, Yodit Abraham Yaynishet, Chinasa Kalaiwo, 

Organizations: School of Biomedical Engineering & Imaging Sciences, King’s College London, London, United Kingdom · Medical Artificial Intelligence, Crestview Radiology Ltd., Lagos, Nigeria · King’s College Hospital NHS Foundation Trust, London, United Kingdom · Department of Radiology, Guy’s and St. Thomas’ NHS Foundation Trust, London, United Kingdom · 

Abstract

High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved

Figures & tables

Appendix figures & tables9 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 23, 2026

Single-Subject Multi-View MRI Super-Resolution via Implicit Neural Representations

Clinical MRI frequently acquires anisotropic volumes with high in-plane resolution and low through-plane resolution to reduce acquisition time. Multiple orientations are therefore acquired to provide complementary anatomical information. Conventional integration of these views relies on registration followed by interpolation, which can degrade fine structural details. Recent deep learning-based super-resolution (SR) approaches have demonstrated strong performance in enhancing single-view images. However, their clinical reliability is often limited by the need for large-scale training datasets, resulting in increased dependence on cohort-level priors. Self-supervised strategies offer an alternative by learning directly from the target scans. Prior work either neglects the existence of multi-view information or assumes that in-plane information can supervise through-plane reconstruction under the assumption of pre-alignment between images. However, this assumption is rarely satisfied in clinical settings. In this work, we introduce Single-Subject Implicit Multi-View Super-Resolution for MRI (SIMS-MRI), a framework that operates solely on anisotropic multi-view scans from a single patient without requiring pre- or post-processing. Our method combines a multi-resolution hash-encoded implicit representation with learned inter-view alignment to generate a spatially consistent isotropic reconstruction. We validate the SIMS-MRI pipeline on both simulated brain and clinical prostate MRI datasets. Code will be made publicly available for reproducibility: https://github.com/abhshkt/SIMS-MRI
Jul 7, 2026

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.
Mar 10, 2026

Physics-Driven 3D Gaussian Rendering for Zero-Shot MRI Super-Resolution

High-resolution Magnetic Resonance Imaging (MRI) is vital for clinical diagnosis but limited by long acquisition times and motion artifacts. Super-resolution (SR) reconstructs low-resolution scans into high-resolution images, yet existing methods are mutually constrained: paired-data methods achieve efficiency only by relying on costly aligned datasets, while implicit neural representation approaches avoid such data needs at the expense of heavy computation. We propose a zero-shot MRI SR framework using explicit Gaussian representation to balance data requirements and efficiency. MRI-tailored Gaussian parameters embed tissue physical properties, reducing learnable parameters while preserving MR signal fidelity. A physics-grounded volume rendering strategy models MRI signal formation via normalized Gaussian aggregation. Additionally, a brick-based order-independent rasterization scheme enables highly parallel 3D computation, lowering training and inference costs. Experiments on two public MRI datasets show superior reconstruction quality and efficiency, demonstrating the method's potential for clinical MRI SR.