cs.AINov 17, 2026

When Lower Harm Misleads: Auditing Concept Corrections

Authors: Tianyou Lai, Wentao Yue, Hongji Li, Chaoyuan Hao, Qilei Li

Organizations: Carnegie Mellon University · The Hong Kong Polytechnic University · Mohamed bin Zayed University of Artificial Intelligence · University of Chinese Academy of Sciences · 

Abstract

An expert who corrects a concept prediction, such as a BI-RADS descriptor in breast ultrasound, expects the diagnosis to improve. Objectives that reduce the harm of such corrections are judged by harm and accuracy, yet harm also falls when a model responds less to every correction or starts from a worse uncorrected prediction, the reference for harm. We propose a correction audit, a reproducible evaluation protocol that separates these explanations: it splits each correction into harm and useful gain on identical events, separates the starting prediction from the correction response, and compares objectives with amplitude baselines matched in source harm. On three breast-ultrasound sources, worst-case correction training, evaluated from the mean-case model's start, lowers harm but gives up more useful gain in all 21 source comparisons pooled over six seeds, raising the corrected negative log-likelihood (NLL); from the same start, selecting between the objectives by harm picks the less helpful model on all three sources. On CUB, a monotonic harm penalty at its reported weight lowers path-level harm in all 80 concept sets while raising the NLL in all 80, almost entirely before any correction. At a fixed start, rescaling both responses to the same source harm reproduces the penalty's mean harm, useful gain and NLL on single-concept corrections within a prespecified margin of 0.0005 nat, although the two responses point in different directions. Lower harm therefore signals better corrections only when it is read together with useful gain, absolute risk and the start it is measured from.

Figures & tables

Appendix figures & tables37 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Aug 17, 2026

Prior Audit-Repair Context Shifts LLM Verifier Thresholds Toward Leniency

Automated checking pipelines increasingly place one language model as the checker and another (or the same one) as the fixer. We ask whether that wiring changes what the checker reports. Measuring false alarms on human-verified-correct ProcessBench traces with the present task held byte-identical, we find that a completed audit -> repair episode already in the model's context lowers false alarms in 15 of 15 model x wording combinations, by 2.8 to 11.5 percentage points against a length-matched non-audit control, a 9 to 25% reduction relative to that control. The direction contradicts what the accumulated-message literature predicts: an episode whose audit reported an error lowers false alarms further still, at all five wordings on the model where that manipulation lands cleanly, though a negativity asymmetry predicts more flagging. Decomposing the episode finds repair content and audit verdict complementary: different components carry the effect on different model families. Signal-detection analysis locates the change in the threshold rather than in discrimination -- the criterion moves in 15 of 15 combinations and survives correction in 13 while d' survives in none, though the d' test is half as sensitive by construction -- and a hand audit of 50 false alarms finds 82% simply wrong, so at this operating point the shift need not be harmful. With reasoning enabled the effect keeps its relative size on both models tested, and the threshold reading holds there too.
Oct 12, 2026

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.
Sep 14, 2026

Rethinking Correctness for Uncertainty Estimation in Clinical Prediction with Vision-Language Models

Vision-language models are increasingly explored for clinical prediction from electronic health records and medical images, where identifying unreliable predictions is important for safe deployment. Uncertainty estimation (UE) enables detecting such predictions, but its evaluation depends on a correctness criterion that determines whether each model output is correct. If this criterion disagrees with human judgement or distorts downstream UE performance, conclusions about model reliability can be misleading. We introduce a two-axis framework that evaluates correctness criteria by their agreement with human judgements and fidelity to human-referenced UE performance. We assess eight criteria across three clinical prediction tasks and three models using 450 predictions annotated by two reviewers. Across the audited tasks, canonical exact matching (EM) achieved the highest observed human agreement and lowest UE distortion, while the BERT-based matching (BEM) and LLM-judge also showed strong human agreement. Across four UE methods and 23,254 clinical predictions, criterion choice changed error-detection AUROC by up to 0.146 and reversed the relative ranking of UE methods. The LLM-judge also selectively accepted invalid or uncertain outputs, accepting 16 of 30 such human-identified errors. These results demonstrate that correctness assessment is an integral component of clinical UE evaluation and should be validated before UE methods are compared.