cs.CVNov 17, 2026

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

Authors: Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen

Organizations: Department of Emergency Medicine, Chang Gung Memorial Hospital, Keelung, Taiwan · Institute of Health Data Science, College of Intelligent Computing, Chang Gung University, Taoyuan, Taiwan · Department of Artificial Intelligence, College of Intelligent Computing, Chang Gung University, Taoyuan, Taiwan · Artificial Intelligence Research Center, Chang Gung University, Taoyuan, Taiwan · 

Abstract

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

Figures & tables

Appendix figures & tables11 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 17, 2026

When Can Test-Time Adaptation Help Zero-Shot CT Vision-Language Models?

3D CT vision-language models (VLMs) classify abnormalities from text prompts in a zero-shot manner, enabling cross-institution deployment where labels are scarce and clinical tasks shift faster than supervised models can be retrained. A real CT scan, however, typically contains several co-occurring abnormalities, and the reliability of zero-shot multi-label prediction under distribution shift remains poorly understood. Test-time adaptation (TTA) updates a model on unlabeled target scans without source data or target annotations, yet existing TTA methods target multi-class softmax prediction on natural images or 2D medical segmentation, and none addresses unsupervised multi-label adaptation for zero-shot 3D CT VLMs. We study when TTA helps zero-shot 3D CT VLMs. A controlled diagnostic analysis shows that TTA is conditional: the volumetric input must preserve the encoder's depth structure, and the base representation must transfer to the target cohort, with depth reduction alone lowering internal AUROC by more than 0.12. We then focus on the regime where the base model already separates present from absent abnormalities. We introduce CARVE (Cardinality-Aware Retained-View Entropy), the first TTA method for this setting. CARVE estimates a sample-specific positive-label cardinality k^\hat{k}, optimizes a top-k^\hat{k} objective to preserve co-occurring abnormalities, and performs memory-efficient multi-view adaptation by scoring weak 3D views without gradients before updating on a retained subset. Across contrastive CT-CLIP and anatomy-aware fVLM, CARVE provides the most consistent improvements across multi-label, three-class, and binary CT tasks when the base model is already discriminative. These results establish multi-label TTA for zero-shot 3D CT VLMs as a distinct problem and CARVE as a cardinality-aware solution.
Jun 15, 2026

Revisiting LLM Adaptation for 3D CT Report Generation: A Study of Scaling and Diagnostic Priors

Recent advances in multimodal learning, including large language models (LLMs) and vision-language models (VLMs), have demonstrated strong adaptability to natural images. However, extending their use to the medical domain, particularly for volumetric (3D) images, is challenging due to high computational complexity, volumetric dependencies and the semantic gap between visual features and clinical terminology. Naively fine-tuning LLMs on limited medical data often leads to overfitting and clinical hallucination, where linguistic fluency is prioritized over clinical factuality. In this study, we investigate parameter-efficient adaptation strategies for volumetric CT report generation and introduce RAD3D-Prefix, a lightweight diagnostic-prior conditioning framework that minimizes the need for extensive parameter training. This module integrates image embeddings with multi-label diagnostic classification logits, preserving critical clinical details while bridging the semantic gap. By keeping the LLM frozen, our method requires minimal trainable parameters and mitigates the risk of overfitting on small, domain-specific datasets. Through a systematic study spanning LLMs from 96.1M to 1.6B parameters, we find that fine-tuning is most beneficial for smaller LLMs, whereas freezing larger (~1B+ LLMs and training only lightweight projection layers provides a superior trade-off between performance, generalization, and computational efficiency. Across multiple automatic metrics and a clinical reader study, RAD3D-Prefix outperforms comparable parameter-efficient baselines and demonstrates strong out-of-domain generalization while using substantially fewer trainable parameters than fully fine-tuned alternatives.
Jun 24, 2026

Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed Tomography

Vision-language pre-training (VLP) holds great promise for general-purpose medical AI by leveraging radiology reports as rich textual supervision, yet existing methods struggle with 3D CT imaging due to inefficient visual backbones and coarse semantic alignment. To address these issues, we propose a tailored VLP framework featuring three key components: (1) a CNN-ViT hybrid encoder that replaces ViT's patch embedding with a 3D CNN backbone to efficiently capture local anatomical details while preserving global attention and compatibility with pre-trained cross-modal priors; (2) a disease-level contrastive learning mechanism using learnable query tokens to dynamically extract disease-specific semantics from full reports and align them with corresponding visual features, thereby disentangling distinct diseases within the same anatomical region; and (3) a diagnosis-aware prompt strategy that employs real clinical phrases and aggregated disease prototypes to bridge the pre-training-inference gap and enhance zero-shot diagnostic reliability. Our model achieves state-of-the-art performance on CT-RATE (84.4% AUC, +5.1%) and Rad-ChestCT (75.4% AUC, +5.4%), with even larger gains (+9.8% AUC) on a challenging 60-disease benchmark, and demonstrates strong transferability to radiology report generation, underscoring the generality and clinical utility of our approach.