Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was 25.2±4.3 Nm and 30.6±9.5 Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to 17.9±4.6 Nm and offered increased assistance of 37.7±6.4 Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.
Figures & tables
Fig. 1: Exploded-view of the mechanical frame for integrating the actuation system. The alignment hinge allowed preservation of passive degrees of freedom.
Fig. 2: Measured torso–pelvis angle θ and effective exoskeleton angle ϕ in upright (left), stoop (middle), and squat (right) postures.
Fig. 3: Target nominal bending and lifting assistance command torques.
Fig. 4: Back and side profiles of the Levio system with the Laevo frame and integrated active components. The actuator is positioned between the torso-side force-transfer bars and the thigh-side structure, while the separate alignment hinge accommodates out-of-plane leg motion. The first two panels include 3D-printed prototype parts, whereas the rightmost panel shows the final version with machined parts.
Fig. 5: Cycle normalized average torso-pelvis angle ( θ ) measured across the three lifting conditions. The shaded region shows the standard deviation across participants.
Fig. 6: Cycle normalized average assistive torques τestimated across conditions. The shaded region shows the standard deviation across participants.
Fig. 7: Work-loops demonstrating the relation between τestimated and θ across the three conditions. Solid line denotes the bending phase, whereas the dotted line denotes the lifting phase of the respective conditions.
Condition
Mean ± SD
Median [range]
Passive
76.9±13.2
72.5 [62.5–97.5]
Zero torque
65.3±26.6
72.5 [15.0–95.0]
Active assistance
81.7±12.6
77.5 [60.0–100.0]
TABLE I: System Usability Scale results for stoop ( n=9 ).
Fig. 8: Average difference in assistance between the conditions measured as active assistance−passive . Positive torques demonstrate higher assistance during the active assistance condition. The shaded region shows the standard deviation across participants.
Condition
Mean ± SD
Median [range]
Passive
3.6±1.0
3.0 [2.0–5.0]
Zero torque
3.8±1.9
4.0 [2.0–7.0]
Active assistance
2.6±1.6
2.0 [1.0–6.0]
TABLE II: Global discomfort VAS results for stoop ( n=9 ).
Region
Passive
Zero-torque
Active
Chest
1.7±1.5
1.4±1.2
1.2±0.8
Upper back
1.4±0.9
1.8±1.6
1.0±0.7
Lower back
2.8±1.9
3.3±2.9
1.4±1.0
Abdomen
1.6±1.7
2.1±2.5
1.3±1.4
Front legs
2.8±1.9
2.3±1.7
2.1±1.4
Back legs
1.1±0.9
1.4±1.6
0.9±0.8
TABLE III: Body-region discomfort VAS for stoop (mean ± SD, n=9 ).
Portable active back support devices (BSDs) offer tunable assistance but are often bulky and heavy, limiting their usability. In contrast, passive BSDs are lightweight and compact but lack the ability to adapt their assistance to different back movements. We present a soft, lightweight, and compact BSD that combines a variable-stiffness passive element and an active element (an artificial muscle) in parallel. The device provides tunable assistance through discrete changes in stiffness values and active force levels. We validate the device's tuning capabilities through bench testing and on-body characterization. Further, we use the device's tuning capabilities to provide weight-adaptive object lifting and lowering assistance. We detect the weight handled by the user based on forearm force myography and upper-back inertial measurement unit data. Furthermore, electromyography analyses in five participants performing symmetric object lifting and lowering tasks showed reductions in back extensor activity. Preliminary results in one participant also indicated reduced muscle activity during asymmetric lifting.
Rohan Khatavkar, The Bach Nguyen, Inseung Kang +2
Arizona State University · Carnegie Mellon University
Providing assistance across diverse movements is a central objective of exoskeletons, and anatomical knowledge can enable responsive support that generalizes across tasks. However, anatomical assistance has mainly been studied for lower-limb exoskeletons, where periodic, weight-bearing motions impose lower demands on torque precision. Extending such assistance to complex, nonperiodic upper-limb movements remains challenging. This paper proposes Anatomical Torque with Passivity-Based Control (ATP) for safe upper-limb exoskeleton assistance. First, a scalable musculoskeletal simulation framework trains a unified reinforcement-learning muscle controller that generalizes across upper-limb movements and generates anatomical reference torques without complex biomechanical computations. Second, an online torque-refinement scheme adapts the reference to diverse movements, suppresses tendon-induced spikes, and incorporates a learned anomaly score for safe and comfortable assistance. Third, an interaction torque controller delivers assistance through a cable-driven compliant exoskeleton without constraining motion to predefined trajectories, while an energy tank preserves passivity with theoretical guarantees on torque tracking and system passivity. Simulations and real-world experiments show accurate tracking of long-duration motion sequences and generalization to real-time human movements. The controller achieves accurate torque tracking while preserving passivity and resumes tracking after energy-tank replenishment. An EMG study with five participants further shows reduced target-muscle activity during static and dynamic tasks compared with gravity compensation and open-loop assistance, with reductions of up to 48% relative to movement without the exoskeleton in a dynamic multi-joint task.
Yu Chen, Gong Chen, Xiang Li
Department of Automation, Tsinghua University, China · Shenzhen MileBot Robotics Co., Ltd, China
Hip exoskeletons provide an important hardware basis for lower-limb rehabilitation and locomotor assistance. Laboratory rehabilitation assessment and system development require substantial actuation and computing resources, whereas mobile assistance requires untethered portability. Integrating both capabilities within one reusable platform remains a central design challenge. This paper presents a reconfigurable bidirectional cable-driven hip exoskeleton platform that rapidly switches between bench-mounted and backpack-mounted actuation while sharing one cable-free wearable hip interface. The platform modularly adapts the actuation configuration, end-effector sensing path, and low-level control interface. Each cable-driven end-effector weighs 0.405 kg, excluding the cable and actuation unit, and integrates an encoder and a torque sensor; experiments validated bench-mounted admittance-based motion tracking capability and backpack-mounted open-loop torque tracking. Human-worn experiments with three healthy participants used myoMOTION to evaluate the platform's wearable-side hip-motion sensing capability, verified bench-to-backpack and backpack-to-bench motion-ready switching across 30 trials in 30.1±16.3 s, and formed a small-scale multimodal wearable-exoskeleton gait dataset for sensing validation and data-driven algorithm development, comprising 8 min bench-mounted treadmill records and 11 min backpack-mounted outdoor walking records. These results show that, by unifying the wearable structure, actuation interface, and sensing path, the proposed platform enables validation of the same hip exoskeleton in both bench-mounted and backpack-mounted configurations, providing reusable hardware for iterative development and applications across scenarios.
YuanLong Ji, Shuhan Xiang, Qihan Ye +1
School of Biological Science and Medical Engineering, Beihang University; the Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education; Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology; National Medical Innovation Platform for Industry-Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering), Beihang University, Beijing, 100191, China