eess.IVNov 17, 2026

Gaussian Splatoms: Direct Atomic Structure Identification in Electron Tomography

Authors: Nalini Singh, Tiffany Chien, Cedric Lim, Arthur R. C. McCray, Colin Ophus, Laura Waller

Organizations: Department of Electrical Engineering and Computer Science, UC Berkeley, Cory Hall, Berkeley, 94720, CA, USA · Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, 94305, CA, USA

Abstract

Atomic electron tomography (AET) computationally reconstructs the 3D atomic structure of materials from a series of 2D projection measurements acquired at different tilt angles. Inspired by Gaussian splatting techniques from computer vision, we introduce an atom-centric parameterization for modeling AET samples. Instead of a conventional volumetric representation with a grid of voxels, we model the sample as a list of atoms, where each atom is a 3D Gaussian characterized by learned location, scale, and amplitude. The Gaussian model is a natural fit for atoms that allows us to easily incorporate prior information grounded in physics; we impose isotropy of atoms, a minimum interatomic distance, and realistic atomic radii. We show in simulation that our method is more robust than volumetric baselines to real-world imaging challenges, including a limited number of measurements and low electron dose. We further show that our method yields a more physically plausible reconstruction of an experimental 23,000 atom iron-platinum nanoparticle than a previously published volumetric reconstruction. Beyond tomography, our representation is a promising tool for any atomic resolution imaging modality (e.g. multislice electron ptychography).

Figures & tables

Explore similar work

Apr 6, 2026

3D Gaussian Splatting for Annular Dark Field Scanning Transmission Electron Microscopy Tomography Reconstruction

Analytical Dark Field Scanning Transmission Electron Microscopy (ADF-STEM) tomography reconstructs nanoscale materials in 3D by integrating multi-view tilt-series images, enabling precise analysis of their structural and compositional features. Although integrating more tilt views improves 3D reconstruction, it requires extended electron exposure that risks damaging dose-sensitive materials and introduces drift and misalignment, making it difficult to balance reconstruction fidelity with sample preservation. In practice, sparse-view acquisition is frequently required, yet conventional ADF-STEM methods degrade under limited views, exhibiting artifacts and reduced structural fidelity. To resolve these issues, in this paper, we adapt 3D GS to this domain with three key components. We first model the local scattering strength as a learnable scalar field, denza, to address the mismatch between 3DGS and ADF-STEM imaging physics. Then we introduce a coefficient γγ to stabilize scattering across tilt angles, ensuring consistent denza via scattering view normalization. Finally, We incorporate a loss function that includes a 2D Fourier amplitude term to suppress missing wedge artifacts in sparse-view reconstruction. Experiments on 45-view and 15-view tilt series show that DenZa-Gaussian produces high-fidelity reconstructions and 2D projections that align more closely with original tilts, demonstrating superior robustness under sparse-view conditions.
Nov 18, 2026

4D-TEMPO: Differentiable 4D-STEM ptychography via fast Physics Optimizers

Electron ptychography recovers atomic structure from 4D-STEM data: diffraction patterns at multiple positions of a scanned probe. Current codes reconstruct an image and read atoms off it, or fit atoms under an L1L_1 loss; neither gives per-atom uncertainty. We propose 4D-TEMPO, a differentiable physical renderer that fits the atoms, the microscope, and the detector directly to the recorded electron counts under a Poisson likelihood. The output is a list of atoms, each a Gaussian primitive with a 3D position, a thermal width, and a model-conditional error bar from the Fisher information. The Fisher information also conditions the solver, gives the dose (electrons per Å2^2) each parameter needs, and separates calibration from imaging. On a simulated WSe2_2 bilayer, starting from the published reconstruction, fitted atoms cut in-plane error by a third (3.2 vs. 4.8 pm) and depth error by 40-61% against its 3D peaks. Depth comes from multiple scattering into the dark field, the faint counts outside the direct beam. The two layers, 10×10\times closer than the depth of field, separate; per-atom depth then follows the layer geometry. When the model is well specified, the bars are calibrated (69% of position coordinates within 1σ1σ). On experimental WSe2_2, fitted atoms predict held-out patterns better than the three published codes we test. With free probe modes where atoms are incomplete, the same likelihood predicts best on all three held-out benchmarks, matches every WSe2_2 baseline in 5 min against up to 20.5 h, and passes torchslice at its released setting 180×\times sooner on PrScO3_3. Per-atom error bars, planned doses, and fast reconstruction point to low-dose, real-time 3D imaging of beam-sensitive and dynamic materials.
Apr 2, 2026

FaCT-GS: Fast and Scalable CT Reconstruction with Gaussian Splatting

Gaussian Splatting (GS) has emerged as a dominating technique for image rendering and has quickly been adapted for the X-ray Computed Tomography (CT) reconstruction task. However, despite its growing popularity, the benefits of GS are typically not substantial enough to motivate a transition from well-established reconstruction algorithms. This paper addresses the most significant remaining limitations of the GS-based approach by introducing FaCT-GS, a framework for fast and flexible CT reconstruction. Enabled by an in-depth optimization of the voxelization and rasterization pipelines, our new method is significantly faster than its predecessors and scales well with projection and output volume size. Furthermore, the improved voxelization enables rapid fitting of Gaussians to pre-existing volumes, which can serve as a prior for warm-starting the reconstruction, or simply as an alternative, compressed representation. FaCT-GS is over 4X faster than the State of the Art GS CT reconstruction on standard 512x512 projections, and over 13X faster on 2k projections. Implementation and data available through: https://github.com/PaPieta/fact-gs.