cs.CVNov 18, 2026

ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT

Authors: Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong, Junjie Huang, Tianye Niu, Lequan Yu

Organizations: The University of Hong Kong · The University of Sydney · Chongqing University · University of Science and Technology of China · 

Abstract

Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.

Figures & tables

Appendix figures & tables33 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. Posterior Variance Is a Constraint Map, Not an Error Map: Closed-Form Uncertainty for Radiative Gaussian Splatting in Sparse-View CT

    Jul 15, 2026Chulin Zhao, Yiran Xu, Shu Liu3D Gaussian SplattingUncertainty Quantification

  2. Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

    Oct 5, 2026Honglei Brinkmann, Carola-Bibiane Schönlieb, Ander BiguriSparse-View CT ReconstructionComputed Tomography

  3. SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT Reconstruction

    Sep 12, 2026Song Ni, Haijun Yu, Haodong Li +4Sparse-View CT ReconstructionLDCT Reconstruction