cs.CVNov 18, 2026

When accuracy hides risk: risk-controlled confirmation of the critical view of safety under expert disagreement

Authors: Bowen Xiang, Xiao Yu, Mingze Xu

Organizations: Department of Biomedical Engineering, Vanderbilt University, 2301 Vanderbilt Place, Nashville, TN, 37235, USA · Xiangshu MedTech, Hangzhou, China

Abstract

Automated assessment of the critical view of safety (CVS) in laparoscopic cholecystectomy has advanced rapidly, but a deployed check must decide, before the first clip, whether to confirm CVS. The standard rule calibrates a threshold so that false confirmations are rare on average. We show that this rule concentrates its errors on disputed videos, which one of three expert raters judged sufficient, and that the failure is structural. When reference labels are votes of a panel sampled from a larger expert pool, the rule that maximizes sensitivity at a fixed average false-confirmation rate also maximizes false confirmation of disputed videos, and for recognizers that recover expert judgement with less noise this rate rises with accuracy. We propose certified confirmation, a risk-controlled monitoring rule whose threshold is selected by multiple testing so that, with probability at least 1 - δ, false confirmation is at most α overall, among disputed videos, within vendor and country groups, and before CVS is visible, using disputed labels only to calibrate. In a pre-specified, hash-locked evaluation on the 300 test videos (18 countries) of the SAGES CVS Challenge, standard calibration falsely confirmed 8 of 39 disputed videos (0.21; one-sided p = 0.037 against α = 0.10), whereas certified confirmation confirmed 2 (one-sided 95% upper bound 0.15). On development data, protection held for vendor and country groups left out of calibration. The cost was confirming 10% rather than 35% of sufficient videos on time. Average accuracy hides this risk; disputed cases must be protected explicitly.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 24, 2026

Sum-of-Checks: Structured Reasoning for Surgical Safety with Large Vision-Language Models

Purpose: Accurate assessment of the Critical View of Safety (CVS) during laparoscopic cholecystectomy is essential to prevent bile duct injury, a complication associated with significant morbidity and mortality. While large vision-language models (LVLMs) offer flexible reasoning, their predictions remain difficult to audit and unreliable on safety-critical surgical tasks. Methods: We introduce Sum-of-Checks, a framework that decomposes each CVS criterion into expert-defined reasoning checks reflecting clinically relevant visual evidence. Given a laparoscopic frame, an LVLM evaluates each check, producing a binary judgment and justification. Criterion-level scores are computed via fixed, weighted aggregation of check outcomes. We evaluate on the Endoscapes2023 benchmark using three frontier LVLMs, comparing against direct prompting, chain-of-thought, and sub-question decomposition, each with and without few-shot examples. Results: Sum-of-Checks improves average frame-level mean average precision by 12--14% relative to the best baseline across all three models and criteria. Analysis of individual checks reveals that LVLMs are reliable on observational checks (e.g., visibility, tool obstruction) but show substantial variability on decision-critical anatomical evidence. Conclusion: Structuring surgical reasoning into expert-aligned verification checks improves both accuracy and transparency of LVLM-based CVS assessment, demonstrating that explicitly separating evidence elicitation from decision-making is critical for reliable and auditable surgical AI systems. Code is available at https://github.com/BrachioLab/SumOfChecks.
Sep 23, 2026

CasCVS-Net: A Staged Multi-Task Cascade for Critical View of Safety Assessment

Automated assessment of the Critical View of Safety (CVS) in laparoscopic cholecystectomy requires both recognition of the three CVS criteria and anatomical grounding in small, rare, and often occluded hepatocystic structures. Learning-based methods differ in the anatomical information they use, from image-level classification to detection, segmentation, or graph-based reasoning, yet grounding the safety-critical anatomy remains the main bottleneck. We propose CasCVS-Net, a staged multi-task cascade that jointly performs object detection, semantic segmentation, and CVS assessment, trained on the Endoscapes dataset. The model couples the tasks through predicted anatomy: predicted boxes guide segmentation, and predicted masks provide region-level features for CVS classification, so CVS assessment at inference uses only model predictions rather than ground-truth annotations. To reduce optimisation instability in this coupled setting, training progresses from detection to detection-segmentation and then to the full three-task cascade, followed by task-wise fine-tuning. Evaluation on the public unseen test set shows that CasCVS-Net improves over matched single-task baselines on all three tasks, achieving 32.0 detection mAP, 46.8 semantic mIoU, 15.3 rare-anatomy mIoU, and 67.2 CVS mAP. It outperforms the state-of-the-art LG-CVS and SV2LSTG by 6.3% and 4.5% relative CVS mAP, respectively, corresponding to 4.0 and 2.9 mAP points. These results show that staged task coupling through predicted boxes and masks improves anatomical grounding for CVS assessment, particularly for rare hepatocystic structures.
Sep 25, 2026

Structured Reasoning Agentic Framework for Interpretable Critical View of Safety Assessment

Surgical scene understanding is critical for computer-assisted intervention, yet laparoscopic cholecystectomy remains challenged by the complex anatomy of the hepatocystic triangle and the risk of bile duct injury. Existing methods for Critical View of Safety (CVS) assessment typically treat it as a holistic prediction task, mapping visual features directly to criterion-level labels. This black-box paradigm lacks explicit reasoning about anatomical relationships, limiting both interpretability and compositional generalization. To address this, we propose ReasonCVS, a structured reasoning agentic framework empowered by Vision-Language Models (VLMs) that decomposes CVS assessment into explicit, fine-grained anatomical verification. Specifically, we devise an Anatomical Scene Graph Abstraction (ASGA) that organizes anatomical entities and their spatial relationships into a structured representation. To operationalize this, we introduce a Rationale-Aware Reasoning Agent, powered by a Large Language Model (LLM) fine-tuned via rationale distillation. Functioning as a strict central decision-maker, it invokes VLM-driven Sub-criterion Verifier as a specialized perceptual tool to parse the graph and independently evaluate individual sub-criteria. Through calibrated soft reasoning, this agent synthesizes the tool-gathered distributed observations, yielding a final verdict alongside a traceable clinical rationale. Extensive experiments on the Endoscapes-CVS201 benchmark demonstrate that ReasonCVS achieves superior performance (68.1% mAP) over state-of-the-art while providing interpretable, criterion-level explanations for reliable surgical assessment.