cs.RONov 18, 2026

Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable model

Authors: Lisette Masselink, Xiaolong Zhu Thomas George Thuruthel, Mohamed Irfan Refai

Organizations: Chair of Neuromuscular Robotics, Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands · School of Medical Technology, Beijing Institute of Technology, Beijing, China · Department of Computer Science, University College London, London, U.K.

Abstract

The human-exoskeleton interaction interface, consisting of the exoskeleton attachment and the underlying human soft tissue, can affect the transfer of assistance. MuJoCo's flexcomp has been previously used to model the soft tissue, but its accuracy has not been benchmarked against a finite element model. We benchmarked the flexcomp Saint Venant-Kirchhoff (StVK) and Stable Neo-Hookean (SNH) models against COMSOL's Yeoh model in three cases: case 1) spherical indentation, case 2) compression, and case 3) compression of a thigh. We compared force and strain energy as a function of indentation depth, hysteresis and computation time. MuJoCo's models capture force trends with a correlation of 0.97-0.99, but showed a stiffer response, which could be attributed to the volumetric locking of the linear finite elements. The MuJoCo models systematically underestimated hysteresis as MuJoCo's Rayleigh damping could not substitute a viscoelastic model. Moreover, MuJoCo's computational advantage was speed dependent: it was 2-2.5 times faster for spherical indentation, but COMSOL was faster for the other cases, which have more degrees of freedom and contacts. Although MuJoCo's flexcomp offers a combination of soft-tissue modelling and multibody dynamics, the limitations regarding the stiffening and hysteresis should be addressed to be used for the analysis of the human-exoskeleton interaction interface.

Figures & tables

Explore similar work

Aug 21, 2026

Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry

Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency.
Oct 11, 2026

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.
Oct 9, 2026

Composable Dynamics for Cooperative Humanoids: A RoboCompiler Extension

Physically connected humanoids need consistent dynamics for internal actuator loops, inter-robot forces, and changing ground supports. We extend RoboCompiler with member-wise dynamics assembly, compiling reduced dynamics from rigid bodies, moving actuator parts, and reflected rotor inertias. Compiled body Jacobians and analytic constraint curvature yield an explicit Coriolis factor satisfying the power identity for floating-base quasi-velocities. A two-level reduction retains reusable robot models while composing their supports and hand connections; local inertial updates have rank at most six, and prescribed-acceleration constraint wrenches are affine in actuator efforts. These interfaces support actuator-aware tracking, coupled force allocation, payload updates, and support-mode switching for five hand-linked humanoids. Across 264 feasible states in eight humanoid configurations, normalised acceleration discrepancies remain within 1.6 ⁣× ⁣10−101.6\!\times\!10^{-10} against a hard-constraint reference and 1.4 ⁣× ⁣10−101.4\!\times\!10^{-10} against a compiler-independent reference; MuJoCo simulations achieve 0.73~mm root-mean-square (RMS) pelvis error in the ring dance and complete side steps through 20 support-mode changes.