Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

Authors: Sheena Shabana, Laxmi Nag Laxminarayan Nagesh, Marta Vallejo, Karen Donaldson, Maria Koskinopoulou

Organizations: Heriot Watt University, Edinburgh, UK · University of Edinburgh, Edinburgh, UK

Abstract

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92%) and 22/25 tissue acquisition trials (88%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.

Explore similar work

Apr 22, 2026

A Vision-Language-Action Model for Adaptive Ultrasound-Guided Needle Insertion and Needle Tracking

Ultrasound (US)-guided needle insertion is a critical yet challenging procedure due to dynamic imaging conditions and difficulties in needle visualization. Many methods have been proposed for automated needle insertion, but they often rely on hand-crafted pipelines with modular controllers, whose performance degrades in challenging cases. In this paper, a Vision-Language-Action (VLA) model is proposed for adaptive and automated US-guided needle insertion and tracking on a robotic ultrasound (RUS) system. This framework provides a unified approach to needle tracking and needle insertion control, enabling real-time, dynamically adaptive adjustment of insertion based on the obtained needle position and environment awareness. To achieve real-time and end-to-end tracking, a Cross-Depth Fusion (CDF) tracking head is proposed, integrating shallow positional and deep semantic features from the large-scale vision backbone. To adapt the pretrained vision backbone for tracking tasks, a Tracking-Conditioning (TraCon) register is introduced for parameter-efficient feature conditioning. After needle tracking, an uncertainty-aware control policy and an asynchronous VLA pipeline are presented for adaptive needle insertion control, ensuring timely decision-making for improved safety and outcomes. Extensive experiments on both needle tracking and insertion show that our method consistently outperforms state-of-the-art trackers and manual operation, achieving higher tracking accuracy, improved insertion success rates, and reduced procedure time, highlighting promising directions for RUS-based intelligent intervention.
Mar 8, 2026

DAISS: Phase-Aware Imitation Learning for Dual-Arm Robotic Ultrasound-Guided Interventions

Imitation learning has shown strong potential for automating complex robotic manipulation. In medical robotics, ultrasound-guided needle insertion demands precise bimanual coordination, as clinicians must simultaneously manipulate an ultrasound probe to maintain an optimal acoustic view while steering an interventional needle. Automating this asymmetric workflow -- and reliably transferring expert strategies to robots -- remains highly challenging. In this paper, we present the Dual-Arm Interventional Surgical System (DAISS), a teleoperated platform that collects high-fidelity dual-arm demonstrations and learns a phase-aware imitation policy for ultrasound-guided interventions. To avoid constraining the operator's natural behavior, DAISS uses a flexible NDI-based leader interface for teleoperating two coordinated follower arms. To support robust execution under real-time ultrasound feedback, we develop a lightweight, data-efficient imitation policy. Specifically, the policy incorporates a phase-aware architecture and a dynamic mask loss tailored to asymmetric bimanual control. Conditioned on a planned trajectory, the network fuses real-time ultrasound with external visual observations to generate smooth, coordinated dual-arm motions. Experimental results show that DAISS can learn personalized expert strategies from limited demonstrations. Overall, these findings highlight the promise of phase-aware imitation-learning-driven dual-arm robots for improving precision and reducing cognitive workload in image-guided interventions.
Jun 4, 2026

Visuotactile and Explicitly Force-Controlled Robotic Ultrasound for Abdominal Volumetric Reconstruction

In this paper, we present a robotic ultrasound acquisition system that integrates stereo vision, touch-based feedback, and expert-informed strategies to perform autonomous and adaptive abdominal scans. The system records freehand motion and force data from expert radiologists, creating a framework to capture transducer motion, applied forces, and anatomical scanning strategies. This expert data is replayed to replicate characteristic scans with the robot, forming a foundation for further autonomous capabilities. Using stereo vision, the system generates three-dimensional topography maps of the patient's abdomen, which are refined through stiffness measurements at key points to delineate the rib cage boundary. These combined techniques enable the robot to execute two distinct scanning paths: an upward-angled sweep beneath the rib cage to visualize structures near the upper abdomen and a perpendicular sweep across soft tissue regions. A compliant, torque-controlled seven degree-of-freedom robotic manipulator is controlled to maintain consistent probe contact through closed-loop force control over the varied anatomical surfaces. Physical experiments demonstrate that the system achieves high-quality imaging comparable to expert scans while dynamically adapting to patient-specific topographies. Furthermore, the robotic system surpasses expert capabilities by enabling three-dimensional volume acquisition, which enhances diagnostic potential and provides volumetric data for advanced analyses. This work highlights the integration of expert knowledge into autonomous robotic systems and underscores the potential of combining perception-based autonomy with physical reasoning for enhanced diagnostic performance.