eess.IVNov 19, 2026

AIstatLab at BraTS-GoAT 2026 Task 3: Quality-Controlled Consensus Pseudo-Labeling and Dense Expert Adaptation

Authors: Heeseung Shin, Changwon Lim

Organizations: Department of AI in Medicine, Chung-Ang University, Seoul 06974, Republic of Korea · Department of Statistics and Data Science, Chung-Ang University, Seoul 06974, Republic of Korea

Abstract

BraTS-GoAT Task 3 evaluates brain-tumor segmentation across heterogeneous entities using shared ET, TC, and WT regions. We present a 3D ResidualEncoderUNet trained with quality-controlled consensus pseudo-labels, a training-only nested-region objective, and a four-expert bottleneck adapter. Five-fold ResEnc-M/L teachers gener ated predictions for 1,138 unlabeled cases; fusion, hierarchy enforcement, and confidence-and-agreement screening retained 983 for training with 1,351 annotated cases. The final five-fold ResEnc-M entry achieved mean DSC 0.834, mean NSD 0.510, and Acalc = 0.6720 on the validation server. Component effects were modest and region-dependent, with the clearest gains on ET. Source code is available at https://github.com/HeeSeung-Shin/Brats2026-Goat-HS.

Figures & tables

Explore similar work

Sep 14, 2026

Assessing nnU-Net Generalization across Brain Tumor Populations in BraTS-GoAT 2026

BraTS-GoAT evaluates tumor segmentation across heterogeneous populations. We trained a conventional 3D nnU-Net on 1,351 labeled cases using five-fold cross-validation and 1,000 epochs per fold. The final predictor averaged all folds and applied test-time mirroring. On pooled official validation, global DSC values were 0.7805, 0.8288, and 0.8854 for enhancing tumor (ET), tumor core (TC), and whole tumor (WT). Under matched fold-0 inference, mean regional Dice decreased from 0.9058 on source out-of-fold (OOF) cases to 0.8310 on pooled validation (difference--0.0747). Mirroring gave small single-fold gains but no clear ensemble benefit; a residual-encoder alternative reached 0.8282 mean Dice. In labeled OOF predictions, failure cases had substantially smaller reference ET volumes; after adjustment for ET and WT volume, lower Dice remained associated with more disconnected ET components and a smaller fraction of ET contained in the largest component.
Sep 21, 2026

Brain Metastases Segmentation for BraTS 2026 Task 1: A Multi-Architecture Comparison

Brain metastases are the most common intracranial malignancy, occurring in roughly 30% of patients with primary solid tumors and carrying a median survival near 5.9 months. Automated segmentation is critical for treatment planning and volumetric monitoring, but metastases are frequently small, numerous, and heterogeneous in size within a single patient. We compare a plain nnU-Net baseline, a Residual Encoder Large (ResEncL) variant, region-based training, and a Primus transformer model for BraTS-METS 2026 Task 1, using patient-grouped cross-validation to prevent leakage from the longitudinal UCSD subset. Primus (label-based) is our strongest individual model by aggregate DSC/NSD, achieving 0.710/0.761 (ET), 0.742/0.785 (TC), 0.683/0.689 (WT), and 0.531/0.436 (RC). ResEncL trails Primus on aggregate DSC/NSD but achieves substantially higher lesion-wise F1 (e.g. ET: 0.452 vs. 0.052); a probability-averaging ensemble of the two only partially preserves ResEncL's F1 advantage (ET lesion-wise F1: 0.064). We further report three postprocessing and label-reconstruction pitfalls we believe generalize beyond this challenge. Code is available at https://github.com/mahdiislam79/BraTS_METS_2026.
Nov 21, 2026

3D-EMCAD: Efficient Multi-scale Convolutional Attention Decoding for Volumetric Brain Tumor Segmentation

Encoder-decoder networks are widely used for volumetric brain tumor segmentation, yet recent trends favor high-capacity decoders that incur steep computational costs in 3D at high spatial resolutions. The Efficient Multi-scale Convolutional Attention Decoder (EMCAD) is a lightweight decoder that achieves strong accuracy at very low cost, but it has been validated only in 2D. Here, we extend EMCAD to volumetric segmentation (3D-EMCAD) by converting all operations to 3D and replacing standard normalization layers with group normalization to suit the small batch sizes of volumetric training. To isolate the impact of decoder choice, we evaluate five decoders: the proposed 3D-EMCAD, a vanilla SegResNet decoder, an Attention U-Net decoder, UNet++, and a plain U-Net decoder using an identical 3D SegResNet encoder and training protocol on BraTS 2020 (369 cases, three-fold cross-validation). The five decoders yield statistically indistinguishable performance: their mean Dice scores span only 0.0071, less than the fold-to-fold variation of most models, and a paired Wilcoxon signed-rank test shows no significant difference between 3D-EMCAD and three of the four baselines. Importantly, 3D-EMCAD achieves this shared accuracy with the fewest decoder parameters (1.15 M) and operations (8.6 G), requiring 7.3×7.3\times fewer operations than UNet++, which scores no higher. These findings demonstrate that decoder capacity beyond a modest budget offers no measurable benefit for volumetric brain tumor segmentation.