AIstatLab at BraTS-GoAT 2026 Task 3: Quality-Controlled Consensus Pseudo-Labeling and Dense Expert Adaptation
Organizations: Department of AI in Medicine, Chung-Ang University, Seoul 06974, Republic of Korea · Department of Statistics and Data Science, Chung-Ang University, Seoul 06974, Republic of Korea
Abstract
BraTS-GoAT Task 3 evaluates brain-tumor segmentation across heterogeneous entities using shared ET, TC, and WT regions. We present a 3D ResidualEncoderUNet trained with quality-controlled consensus pseudo-labels, a training-only nested-region objective, and a four-expert bottleneck adapter. Five-fold ResEnc-M/L teachers gener ated predictions for 1,138 unlabeled cases; fusion, hierarchy enforcement, and confidence-and-agreement screening retained 983 for training with 1,351 annotated cases. The final five-fold ResEnc-M entry achieved mean DSC 0.834, mean NSD 0.510, and Acalc = 0.6720 on the validation server. Component effects were modest and region-dependent, with the clearest gains on ET. Source code is available at https://github.com/HeeSeung-Shin/Brats2026-Goat-HS.
Figures & tables
| DSC | NSD | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Auxiliary | ET | TC | WT | Mean | ET | TC | WT | Mean | |
| Off | .787 | .815 | .883 | .828 | .547 | .498 | .488 | .511 | .6695 |
| On | .790 | .815 | .882 | .829 | .550 | .500 | .488 | .513 | .6710 |
| +.003 | .000 | -.001 | +.001 | +.003 | +.002 | .000 | +.002 | +.0015 | |
| Setting | Pseudo | QC | ET ( ) | TC | WT | Mean |
|---|---|---|---|---|---|---|
| Labeled-only | 0 | – | .865 (268) | .916 | .931 | .904 |
| All-pseudo | 1,138 | No | .864 (269) | .919 | .935 | .906 |
| QC-pseudo | 983 | Strict | .872 (267) | .918 | .935 | .908 |
| Failure criterion | Frequency | Percentage (%) |
|---|---|---|
| Nonempty excluded candidates ( ) | ||
| Insufficient high-confidence foreground fraction ( ) | 55/94 | 58.5 |
| High entropy | 46/94 | 48.9 |
| Low confidence | 37/94 | 39.4 |
| Low margin | 25/94 | 26.6 |
| All excluded candidates ( ) | ||
| DSC | NSD | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Adapter | ET | TC | WT | Mean | ET | TC | WT | Mean | |
| No adapter | .781 | .809 | .880 | .823 | .537 | .492 | .477 | .502 | .6625 |
| .771 | .808 | .879 | .819 | .531 | .490 | .483 | .501 | .6600 | |
| .787 | .806 | .878 | .824 | .546 | .492 | .481 | .506 | .6650 | |
| .798 | .803 | .879 | .827 | .554 | .492 | .479 | .508 | .6675 | |
| .769 | .805 | .880 | .818 | .535 | .494 | .477 | .502 | .6600 | |
| DSC | NSD | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model | ET | TC | WT | Mean | ET | TC | WT | Mean | |
| ResEnc-M | .797 | .823 | .881 | .834 | .547 | .501 | .481 | .510 | .6720 |
| MedNeXt | .791 | .804 | .874 | .823 | .556 | .500 | .480 | .512 | .6675 |
| BI-SegMamba | .781 | .800 | .875 | .819 | .543 | .490 | .480 | .504 | .6615 |
| Three-model ensemble | .797 | .805 | .879 | .827 | .559 | .500 | .488 | .516 | .6715 |
3D Medical Image Segmentation
3D Medical Image Segmentation identifies organs, lesions, and fine structures in volumetric scans for measurement and clinical planning.
See all 246 papers