cs.LGNov 19, 2026

QUBO-based feature selection for MRI undersampling pattern design

Authors: Xiaoxin Huang, Masayuki Ohzeki

Organizations: Graduate School of Information Sciences, Tohoku University, Sendai 980-8579, Japan · Department of Physics, Institute of Science Tokyo, Tokyo 152-8551, Japan · Research and Education Institute for Semiconductors and Informatics, Kumamoto University, Kumamoto 860-0862, Japan · Sigma-i Co., Ltd., Tokyo 108-0075, Japan

Abstract

We formulate undersampling mask design for Cartesian magnetic resonance imaging (MRI) as a feature subset selection problem. Each sampling line is represented by a binary feature indicating whether it is included in each candidate mask. Using candidate masks and their training-set evaluations, we estimate mutual information (MI) and conditional mutual information (CMI). These estimates and a sampling-count penalty define a quadratic unconstrained binary optimization (QUBO) model. The model is solved using simulated annealing and quantum annealing to determine a feature subset and its corresponding sampling mask. We assess the selected subsets on the test set through zero-filled reconstruction in Fourier undersampling simulations using fastMRI knee magnitude reference images, with patient-disjoint training and test sets. At all six tested target sampling rates from 15% to 40%, the resulting reconstructions have lower mean root mean square error than those obtained with four conventional sampling methods. They also have higher mean structural similarity than those obtained using univariate mutual-information ranking at all tested rates. These results support information-theoretic feature selection as an approach to MRI undersampling mask design under the tested zero-filled simulation settings.

Figures & tables

Explore similar work

Apr 14, 2026

Information-Theoretic Optimization for Task-Adapted Compressed Sensing Magnetic Resonance Imaging

Task-adapted compressed sensing magnetic resonance imaging (CS-MRI) is emerging to address the specific demands of downstream clinical tasks with significantly fewer k-space measurements than required by Nyquist sampling. However, existing task-adapted CS-MRI methods suffer from the uncertainty problem for medical diagnosis and cannot achieve adaptive sampling in end-to-end optimization with reconstruction or clinical tasks. To address these limitations, we propose the first task-adapted CS-MRI from the information-theoretic perspective to simultaneously achieve probabilistic inference for uncertainty prediction and adapt to arbitrary sampling ratios and versatile clinical applications. Specifically, we formalize the task-adapted CS-MRI optimization problem by maximizing the mutual information between undersampled k-space measurements and clinical tasks to enable probabilistic inference for addressing the uncertainty problem. We leverage amortized optimization and construct tractable variational bounds for mutual information to jointly optimize sampling, reconstruction, and task-inference models, which enables flexible sampling ratio control using a single end-to-end trained model. Furthermore, the proposed framework addresses two kinds of distinct clinical scenarios within a unified approach, i.e., i) joint task and reconstruction, where reconstruction serves as an auxiliary process to enhance task performance; and ii) task implementation with suppressed reconstruction, applicable for privacy protection. Extensive experiments on large-scale MRI datasets demonstrate that the proposed framework achieves highly competitive performance on standard metrics like Dice compared to deterministic counterpart but provides better distribution matching to the ground-truth posterior distribution as measured by the generalized energy distance (GED).
Mar 13, 2026

Bayesian Uncertainty-Aware MRI Reconstruction

We propose a novel framework for joint magnetic resonance image reconstruction and uncertainty quantification using under-sampled k-space measurements. The problem is formulated as a Bayesian linear inverse problem, where prior distributions are assigned to the unknown model parameters. Specifically, we assume the target image is sparse in its spatial gradient and impose a total variation prior model. A Markov chain Monte Carlo (MCMC) method, based on a split-and-augmented Gibbs sampler, is then used to sample from the resulting joint posterior distribution of the unknown parameters. Experiments conducted using single- and multi-coil datasets demonstrate the superior performance of the proposed framework over optimisation-based compressed sensing algorithms. Additionally, our framework effectively quantifies uncertainty, showing strong correlation with error maps computed from reconstructed and ground-truth images.
Feb 28, 2026

Direct low-field MRI super-resolution using undersampled k-space

Low-field magnetic resonance imaging (MRI) provides affordable access to diagnostic imaging but suffers from prolonged acquisition and limited image quality. Accelerated imaging can be achieved with k-space undersampling, while super-resolution (SR) and image quality transfer (IQT) methods typically rely on spatial-domain post-processing. In this work, we propose a novel framework for reconstructing high-field MR like images directly from undersampled low-field k-space. Our approach employs a k-space dual channel U-Net that processes the real and imaginary components of undersampled k-space to restore missing frequency content. Experiments on low-field brain MRI demonstrate that our k-space-driven image enhancement consistently outperforms the counterpart spatial-domain method. Furthermore, reconstructions from undersampled k-space achieve image quality comparable to full k-space acquisitions. To the best of our knowledge, this is the first work that investigates low-field MRI SR/IQT directly from undersampled k-space.