Early time-series classification (ETSC) balances predictive performance against the amount of observed data. In multimodal settings, modality-associated and fused branches may differ in predictive ability at the same observed prefix, motivating joint decisions about when to stop and which branch should provide the final prediction. We propose COMPASS, a two-stage framework that preserves two modality-associated temporal branches and one fusion branch. The first stage combines cross-modal feature exchange and gated fusion with branch-wise supervision at every prefix. The second stage optimizes a shared four-action controller to continue observation or terminate through one of the frozen branches. Experiments on six physiological and wearable datasets compare COMPASS with multimodal adaptations of five ETSC baselines. COMPASS achieves the best average ranks in accuracy-earliness harmonic mean, AUROC, and earliness within this comparison set. At identical learned stopping times, branch selection improves mean accuracy over fusion readout on five of the six datasets, with gains of 2.35 and 2.16 percentage points on ISRUC-Sleep and UCDDB, respectively. To the best of our knowledge, this is the first work on joint stopping and branch selection for multimodal early time series classification.
Figures & tables
Figure 1: Overall architecture of COMPASS.
Dataset
Target
Selected modalities
Window (s)
N eval
Positive (%)
MIT-BIH PSG
Apnea
ECG + Resp N
30
8,867
34.4 (+)
Apnea-ECG
Apnea
ECG + Resp N
60
3,409
29.4 (+)
UCDDB
Apnea
ECG + Resp N
60
8,744
11.5 (+)
ISRUC-Sleep
Apnea
ECG + Resp N
30
35,267
4.9 (+)
WESAD
Stress
ACC + BVP
60
513
30.0 (+)
VTaC
VT alarm
ECG + ABP
10
1,567
31.5 (+)
Table 1: Dataset configurations and binary classification tasks.
Dataset
Method
HM-ACC ↑
AUROC ↑
EAR ↓
SE ↑
MIT-BIH PSG
TEASER-MM
0.8108 ± 0.0090
0.7381 ± 0.0126
0.0571 ± 0.0013
0.5839 ± 0.0453
ELECTS-MM
0.8726 ± 0.0039
0.8003 ± 0.0106
0.0528 ± 0.0049
0.4329 ± 0.0351
SPN-V2-MM
0.8086 ± 0.0205
0.8060 ± 0.0094
0.0779 ± 0.0071
0.7265 ± 0.0484
CALIMERA-MM
0.8695 ± 0.0028
0.8561 ± 0.0088
0.1008 ± 0.0018
0.7386 ± 0.0315
UTSC-MM
0.8600 ± 0.0053
0.8276 ± 0.0046
0.0806 ± 0.0011
0.7912 ± 0.0075
COMPASS (Ours)
0.8739 ± 0.0017
0.8670 ± 0.0089
0.0354 ± 0.0009
0.7428 ± 0.0176
Table 2: Comparison with multimodal (MM) adaptations of five ETSC baselines (mean ± SD over five folds). ↑ / ↓ : higher/lower is better. Bold/underline: best/second-best mean per dataset.
Dataset
Stopping configuration
HM-ACC ↑
AUROC ↑
EAR ↓
SE ↑
MIT-BIH PSG
Fixed fraction
0.8223 ± 0.0433
0.7737 ± 0.0742
0.0965 ± 0.0551
0.6169 ± 0.1057
Confidence threshold
0.8287 ± 0.0124
0.6454 ± 0.0195
0.1220 ± 0.0144
0.3411 ± 0.0330
COMPASS (Ours)
0.8739 ± 0.0017
0.8670 ± 0.0089
0.0354 ± 0.0009
0.7428 ± 0.0176
Apnea-ECG
Fixed fraction
0.9546 ± 0.0029
0.9854 ± 0.0030
0.0434 ± 0.0000
0.9420 ± 0.0133
Confidence threshold
0.9508 ± 0.0025
0.9833 ± 0.0038
0.0524 ± 0.0059
0.9232 ± 0.0217
COMPASS (Ours)
0.9543 ± 0.0042
0.9863 ± 0.0030
0.0446 ± 0.0014
0.9326 ± 0.0200
Table 3: Comparison of stopping configurations (mean ± SD over five folds). Bold: best mean per dataset.
Dataset
Full HM-ACC ↑
vs. multi-agent (pp)
vs. no gate (pp)
vs. no adapter (pp)
vs. LSTM (pp)
MIT-BIH PSG
0.8739 ± 0.0017
+1.95
+0.22
+0.29
+7.89
Apnea-ECG
0.9543 ± 0.0042
+0.08
+0.35
+0.10
+3.33
UCDDB
0.8772 ± 0.0085
+4.50
+0.51
+0.65
+20.45
ISRUC-Sleep
0.9155 ± 0.0059
+1.98
+0.86
+0.65
+3.60
WESAD
0.9464 ± 0.0071
+0.70
+0.72
+0.37
+19.72
VTaC
0.8108 ± 0.0079
+1.57
+1.49
+3.71
+31.69
Table 4: Component ablations. Full: HM-ACC of the full model (mean ± SD). Other columns: full model minus variant, in percentage points. Positive values favor the full model.
Figure 2: (a) Cumulative stopping distributions averaged over five folds. First-step stopping rates in parentheses. (b) Rescue and harm rates under the matched-stop fixed-fusion readout control. Diamonds show the net Δ ACC in percentage points.
Figure 3: Fold-level Δ ACC (percentage points) under the matched-stop fixed-fusion readout control. Positive values favor branch selection.