eess.IVNov 19, 2026

Which Vertebral Landmark Errors Change a Cobb Angle? Geometry-Weighted Supervision for Radiographic Landmark Regression

Authors: Zizhao Peng

Organizations: Department of Computing, The Hong Kong Polytechnic University, Kowloon, Hong Kong

Abstract

A network that localizes vertebral corners can reduce pixel error while rotating the line used to measure spinal curvature. We derive a training loss from the geometry of a three-angle reader. Of the eight corner-displacement degrees of freedom of a vertebral quadrilateral, one local direction rotates its left-to-right chord. The angular sensitivity in this direction is inversely proportional to chord width. An orthonormal Hadamard basis lets us give this residual extra weight during training while retaining supervision on the other seven directions. In five-fold image-level development experiments on 372 anteroposterior radiographs, we compared three objectives across 45 fits of the same landmark network. The three-seed corner ensemble reduced pooled symmetric percentage error from 18.45% with coordinate supervision to 17.20% with geometry weighting. Adding a soft pairwise-angle term yielded 16.89%, a paired difference of −1.56-1.56 percentage points from coordinate supervision (95% image-bootstrap interval [−2.51,−0.61][-2.51,-0.61]). The interval for the increment from adding the soft term included zero. In a single-fold comparison, direct unit-chord supervision also reduced error, and its difference from geometry weighting was uncertain. Across single-seed runs, rotational residual error fell by 36.1% while normalized corner error rose from 2.60% to 2.71%. Perturbing one vertebra at a time also showed when a small rotation changes the selected end pair. These results identify a measurable trade-off between landmark fidelity and agreement with a specified geometric reader. The evaluation concerns an internal image-level split and landmark-derived target angles.

Figures & tables

Explore similar work

May 5, 2026

Tracing Like a Clinician: Anatomy-Guided Spatial Priors for Cephalometric Landmark Detection

Clinicians trace cephalometric radiographs following a structured anatomical workflow, yet no prior system encodes this into computation. We present a five-phase anatomy-guided pipeline producing confidence-weighted spatial priors that shape HRNet-W32 training, achieving 1.04 mm mean radial error on 25 landmarks across 1,502 radiographs from 7+ imaging devices. A training x inference prior matrix isolates the mechanism: anatomical priors maintain a 1% validation-to-test gap versus 88% without priors (1.94 mm), despite identical validation convergence. The matrix establishes that all trained models are inference-independent, the expanded architecture alone provides no benefit, random priors yield partial but unstable improvement (1.72 mm), and only image-specific anatomically correct priors produce the 1.04 mm result -- functioning as a training-time regularizer requiring no automated prior generation at deployment. Five-fold cross-validation (p=0.0015), patient-level permutation testing (p<0.0001, n=151), quantified Grad-CAM analysis (88% vs. 74% in-zone activation, p<0.001), and clinical measurement validation (skeletal classification kappa=0.79-0.84, zero Class II<->III reversals, ICC>0.95) provide converging evidence. Cross-domain experiments on echocardiography, cervical spine, and hand radiography support the hypothesis that prior effectiveness scales with the spatial entropy of the landmark distribution.
Sep 7, 2026

ARNAI: Artifact Removal Network based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement

Purpose: This study aims to develop an AI framework applicable for postoperative imaging for automated measurement of spinopelvic parameters on radiographs with robustness to the presence of spinal implants. Materials and Methods: We retrospectively reviewed lateral lumbar spine radiographs from two institutions (Internal: January 2017--December 2024; External: October 2021--September 2025). We developed the Restore, Segment, and Measure (RSM) framework, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts in postoperative radiographs. Segmentation and spinopelvic parameter (PT, LL, SS, SCA) measurement performance were assessed using Wilcoxon signed-rank tests and intraclass correlation coefficients. Results: When ARNAI was added to a recent Transformer-based segmentation model, FCBFormer, the mean DSC increased to 0.870 from 0.814, with marked gains at L3--L5 and smaller improvements at L1--L2. On 91 radiographs with implants, the mean L4--L5 segmental Cobb angle error decreased to 4.7 ° from 15.6--16.2 °, an average error reduction of 70%. The ICC for L4--L5 segmental Cobb angle improved to 0.54 (Rater 1) and 0.59 (Rater 2) from 0.18, and ICCs for pelvic tilt, lumbar lordosis, and sacral slope all exceeded 0.70. The improvement in L4--L5 segmental Cobb angle error was statistically significant in the internal implant-containing cohort after correction for multiple comparisons. Conclusion: The proposed RSM framework improved automated spinopelvic parameter measurement in implant-containing postoperative radiographs. By mitigating implant-related artifacts, ARNAI improved segmentation and downstream measurement accuracy, with the greatest benefit observed for L4--L5 segmental Cobb angle estimation, where the mean error was reduced by approximately 70%.
Oct 27, 2026

Dense Representation Learning and Differentiable Shape Modeling for Spine Landmark Detection

Spine landmark detection from spinal X-ray is a key step for estimating spine deformation severity, for building biomechanical models, and for pre-operative planning. We reframe anatomical landmark detection as a pixel-level contrastive representation learning problem, matching dense pixel embeddings with landmark prototypes. Surprisingly, even with a generic U-Net backbone, this formulation results in more discriminative heatmaps compared to the traditional heatmap regression paradigm, leading to improved discrimination between vertebral corners on distinct vertebra. Furthermore, we combine the resulting heatmaps with learnable shape priors over the global configuration of spinal landmarks to resolve ambiguities in landmark locations, yielding a simple and practical approach to spinal landmark detection. Our approach is competitive, in terms of landmark accuracy and clinical parameter estimation, with the state-of-the-art on the public AASCE dataset and on two private spinal X-ray datasets. Our code and pre-trained weights are available at https://github.com/BioMedTP/Pix2Point.