Learning a Rule Bank to Revise 3D CT Reports with Independent Evidence
Organizations: University of Florida, Gainesville, FL, USA
Abstract
Vision--language models can generate fluent radiology reports from 3D chest CT scans, yet they may still omit abnormalities or misstate findings. Independent image analysis using models separate from the report model provides additional observations, but acting on uncertain evidence may introduce new errors. We propose an agent system that learns a revision policy represented as an executable rule bank for each report model. Inspired by experience banks, the agent proposes and refines rules using revision outcomes across development cases. During inference, the retained rules guide local edits using independent classifier predictions and quantitative image measurements without retraining the report model. Unedited sentences are preserved, and each change is linked to the rule that triggered it. On CT-RATE, revision increases CE-F1 by 11.5 points for SelfCue-KD and 0.9 points for NV-Reason-CT, with gains across five draft-sampling seeds. SelfCue-KD's CT-FineBench score also increases by 15.2 points. Draft-only rule learning yields limited gains, while the two image-evidence sources provide complementary benefits for abnormality detection. Measurements also supply numerical details missing from the drafts. These results support learning model-specific rules to control how independent image evidence informs report revision. Code is available at https://github.com/renjie-liang/CT-RuleBank.
Figures & tables
| Setting | CE-F1 | CRG | GREEN | CT-FineBench |
|---|---|---|---|---|
| SelfCue-KD | ||||
| Draft | 46.2 | 43.9 | 50.5 | 26.2 |
| Draft-only learning | 46.2 | 43.9 | 50.4 | 26.3 |
| Classifier evidence | 54.5 | 50.8 | 50.1 | 39.6 |
| Measurement evidence | 50.9 | 45.4 | 50.6 | 28.9 |
| Both evidence sources | 57.7 | 51.9 | 49.8 | 41.4 |
| Revision strategy | CE-F1 | CRG | GREEN | CT- FineBench |
|---|---|---|---|---|
| SelfCue-KD | ||||
| Draft | 46.2 | 43.9 | 50.5 | 26.2 |
| Direct LLM revision | 52.5 | 49.1 | 43.8 | 42.4 |
| Classifier-driven | 58.9 | 53.7 | 48.9 | 44.0 |
| Fixed clinical rubric | 44.4 | 43.5 | 49.3 | 28.3 |
| Rule Bank | 57.7 | 51.9 | 49.8 | 41.4 |
| SelfCue-KD | NV-Reason-CT | |||||
|---|---|---|---|---|---|---|
| Min. precision (%) | Changed (%) | CE-F1 | GREEN | Changed (%) | CE-F1 | GREEN |
| 30 | 86.0 | +12.21 | -1.69 | 51.3 | +1.07 | -0.65 |
| 40 | 86.2 | +11.79 | -1.18 | 42.5 | +1.14 | -0.26 |
| 50 | 85.0 | +11.50 | -0.69 | 25.9 | +0.89 | +0.17 |
| 60 | 60.1 | +8.81 | 0.00 | 19.9 | +0.55 | +0.11 |
| 70 | 49.1 | +6.02 | +0.08 | 20.0 | +0.42 | +0.11 |
| Report model | Changed (%) | CE-F1 | GREEN |
|---|---|---|---|
| SelfCue-KD | |||
| NV-Reason-CT |
| Quantitative reporting on the test set | |||
| Report model | Draft (%) | Revised (%) | Added measurements |
| SelfCue-KD | 18.9 | 31.3 | 517 |
| NV-Reason-CT | 0.3 | 2.9 | 41 |
| Ascending aorta: agreement with reference reports | |||
| Report model | Added | Matched | MAE (mm) |
| SelfCue-KD | 240 | 62 | 2.3 |
| Measurement | Definition | Source regions | Processing and checks | Coverage (%) |
|---|---|---|---|---|
| Cardiothoracic ratio | Largest left-right heart width over the axial slices divided by the largest inner width of the rib cage on the slices that contain the heart | heart, ribs | – | 99.97 |
| Coronary calcium (mm 3 ) | Volume of voxels of at least 130 HU in the coronary region | coronary arteries, bones | Dilate coronary mask by 2 mm; discard components below 1 mm 3 ; exclude bone within 2 mm and metal. Use a soft reconstruction or smooth a sharp-only scan ( mm). | 99.99 |
| Aortic wall calcium (mm 3 ) | Volume of voxels of at least 130 HU in a shell extending 2 mm inside and outside the aortic boundary | aorta | Apply the same bone, metal, and small-component exclusions; exclude the coronary region and slices flagged for mask leakage. Use the same reconstruction handling as for coronary calcium. | 99.99 |
| Pericardial fluid (mL) | Sum of pericardial-effusion component volumes | pericardial effusion | Assign 0 mL when no fluid component is recorded. | 100.00 |
| Pleural fluid (mL) | Total pleural-effusion component volume across both sides | pleural effusion | Assign 0 mL when no fluid component is recorded. | 100.00 |
| Distal esophagus area (mm 2 ) | Largest axial cross-section of the esophagus mask within its lowest 60 mm | esophagus | Locate the lower boundary at the lowest slice with at least 20 mm 2 of esophagus. | 99.99 |
Appendix figures & tables7 assets
Supplementary material from the paper’s appendix.
Appendix
| Report model | Changed decisions | Held-out CE-F1 | Held-out GREEN | Edits |
|---|---|---|---|---|
| SelfCue-KD | 0 | |||
| NV-Reason-CT | 2 |
| Model | Precision | Recall | CE-F1 | CRG | AUROC |
|---|---|---|---|---|---|
| Image classifiers | |||||
| FlexiCT | 57.26 | 67.02 | 61.22 | 54.77 | 87.02 |
| HLIP | 48.19 | 64.71 | 54.16 | 51.11 | 82.89 |
| ASAP | 46.80 | 69.98 | 55.38 | 52.26 | 83.29 |
| Three-classifier mean | 53.54 | 68.86 | 59.73 | 54.47 | 86.52 |
| SelfCue-KD | |||||
| Target abnormality | Measurement and cutoff | Source and supporting text |
|---|---|---|
| Aortic dilation | Ascending aorta diameter mm | ( Munden et al. 2018 ) : “2 SD above the mean diameter as adjusted for age, sex, and body surface area”. Our shared 40 mm cutoff is adapted from population measurements ( Rogers et al. 2013 ) . |
| Coronary artery wall calcification | Coronary calcium volume mm 3 | ( Hecht et al. 2017 ) : “CAC should be evaluated and reported on all noncontrast chest CT examinations”. Presence is mapped to nonzero volume. |
| Hepatic steatosis | Median liver attenuation HU | ( Boyce et al. 2010 ) : “moderate-to-severe hepatic steatosis (defined by liver attenuation HU)”. |
| Cardiomegaly | Cardiothoracic ratio | ( Muangman et al. 2020 ) : Radiograph criterion: “If the CTR is greater than 0.50, cardiomegaly is assumed in the adult patient”. The CT cutoff “was found to be 0.53”. We apply the radiograph value to CT. |
| Arterial wall calcification | Aortic wall calcium volume mm 3 | ( Hecht et al. 2017 ) : “It may be reasonable to evaluate and report thoracic aortic calcification”. Nonzero aortic calcium is our proxy for the broader label. |
| Learning agent / editor agent | CRG | GREEN | CT-FineBench |
|---|---|---|---|
| SelfCue-KD | |||
| gpt-oss / gpt-oss | |||
| Sonnet / gpt-oss | |||
| Sonnet / Sonnet | |||
| NV-Reason-CT | |||
| gpt-oss / gpt-oss | |||
| Vessel | Added | Reference pairs | MAE (mm) |
| SelfCue-KD | |||
| Ascending aorta | 240 | 62 | 2.3 |
| Aortic arch | 0 | 0 | – |
| Descending aorta | 260 | 12 | 2.7 |
| Main pulmonary artery | 17 | 5 | 1.0 |
| NV-Reason-CT | |||
Radiology VLMs
Radiology vision-language models (VLMs) align medical images and text to support grounded diagnosis, reporting, retrieval, and clinical reasoning.
See all 132 papers