Vision--language models can generate fluent radiology reports from 3D chest CT scans, yet they may still omit abnormalities or misstate findings. Independent image analysis using models separate from the report model provides additional observations, but acting on uncertain evidence may introduce new errors. We propose an agent system that learns a revision policy represented as an executable rule bank for each report model. Inspired by experience banks, the agent proposes and refines rules using revision outcomes across development cases. During inference, the retained rules guide local edits using independent classifier predictions and quantitative image measurements without retraining the report model. Unedited sentences are preserved, and each change is linked to the rule that triggered it. On CT-RATE, revision increases CE-F1 by 11.5 points for SelfCue-KD and 0.9 points for NV-Reason-CT, with gains across five draft-sampling seeds. SelfCue-KD's CT-FineBench score also increases by 15.2 points. Draft-only rule learning yields limited gains, while the two image-evidence sources provide complementary benefits for abnormality detection. Measurements also supply numerical details missing from the drafts. These results support learning model-specific rules to control how independent image evidence informs report revision. Code is available at https://github.com/renjie-liang/CT-RuleBank.
Figures & tables
Figure 1: Overview of rule bank learning and report revision. Independent evidence is obtained using image analysis models separate from the report model. The learning agent proposes rules and selects evidence thresholds using CE-F1 and GREEN feedback on development cases. At inference, the editor agent uses the fixed bank and independent evidence to make local edits to the draft.
Table 1: Report generation and RuleBank revision on CT-RATE. RuleBank uses independent image evidence to revise drafts from SelfCue-KD and NV-Reason-CT. † denotes baselines evaluated under our protocol.
Table 2: Performance on changed reports: 1,330 (85.0%) for SelfCue-KD and 405 (25.9%) for NV-Reason-CT. See Appendix C.1 for the full metric breakdown.
Setting
CE-F1
CRG
GREEN
CT-FineBench
SelfCue-KD
Draft
46.2
43.9
50.5
26.2
Draft-only learning
46.2
43.9
50.4
26.3
Classifier evidence
54.5
50.8
50.1
39.6
Measurement evidence
50.9
45.4
50.6
28.9
Both evidence sources
57.7
51.9
49.8
41.4
Table 3: Rule learning with draft-derived signals and different independent evidence sources. Rule banks are learned separately for each evidence setting.
Revision strategy
CE-F1
CRG
GREEN
CT- FineBench
SelfCue-KD
Draft
46.2
43.9
50.5
26.2
Direct LLM revision
52.5
49.1
43.8
42.4
Classifier-driven
58.9
53.7
48.9
44.0
Fixed clinical rubric
44.4
43.5
49.3
28.3
Rule Bank
57.7
51.9
49.8
41.4
Table 4: Comparison of report revision strategies using the same drafts. Direct LLM revision lets the LLM select edits from the draft and independent evidence. Classifier-driven revision uses development-calibrated classifier thresholds. The fixed clinical rubric uses literature-informed measurement cutoffs to guide report revision. Rule Bank uses learned conditions on the draft and evidence to select local edits.
Figure 2: Revision performance over ten learning iterations on the test set. Dashed lines show draft scores. Shading shows 95% CIs for changes from the draft, shifted by the draft scores.
SelfCue-KD
NV-Reason-CT
Min. precision (%)
Changed (%)
Δ CE-F1
Δ GREEN
Changed (%)
Δ CE-F1
Δ GREEN
30
86.0
+12.21
-1.69
51.3
+1.07
-0.65
40
86.2
+11.79
-1.18
42.5
+1.14
-0.26
50
85.0
+11.50
-0.69
25.9
+0.89
+0.17
60
60.1
+8.81
0.00
19.9
+0.55
+0.11
70
49.1
+6.02
+0.08
20.0
+0.42
+0.11
Table 5: Effect of the precision requirement on revision. Δ denotes overall changes from the draft (points).
Report model
Changed (%)
Δ CE-F1
Δ GREEN
SelfCue-KD
83.4±1.9
+10.67±0.80
−0.06±0.15
NV-Reason-CT
24.0±2.9
+0.72±0.33
+0.10±0.26
Table 6: Revision coverage and performance changes across five sampling seeds. Values are mean ± sample SD. A separate rule bank is learned for each seed.
Quantitative reporting on the test set
Report model
Draft (%)
Revised (%)
Added measurements
SelfCue-KD
18.9
31.3
517
NV-Reason-CT
0.3
2.9
41
Ascending aorta: agreement with reference reports
Report model
Added
Matched
MAE (mm)
SelfCue-KD
240
62
2.3
Table 7: Quantitative reporting and reference agreement. MAE is computed on added ascending-aorta diameters with matching reference measurements.
Figure 3: Edit quality assessment and illustrative cases. (a) Reference-report agreement and potential clinical importance of revisions. (b,c) Examples linking independent evidence to local report edits.
Measurement
Definition
Source regions
Processing and checks
Coverage (%)
Cardiothoracic ratio
Largest left-right heart width over the axial slices divided by the largest inner width of the rib cage on the slices that contain the heart
heart, ribs
–
99.97
Coronary calcium (mm 3 )
Volume of voxels of at least 130 HU in the coronary region
coronary arteries, bones
Dilate coronary mask by 2 mm; discard components below 1 mm 3 ; exclude bone within 2 mm and metal. Use a soft reconstruction or smooth a sharp-only scan ( σ=1 mm).
99.99
Aortic wall calcium (mm 3 )
Volume of voxels of at least 130 HU in a shell extending 2 mm inside and outside the aortic boundary
aorta
Apply the same bone, metal, and small-component exclusions; exclude the coronary region and slices flagged for mask leakage. Use the same reconstruction handling as for coronary calcium.
99.99
Pericardial fluid (mL)
Sum of pericardial-effusion component volumes
pericardial effusion
Assign 0 mL when no fluid component is recorded.
100.00
Pleural fluid (mL)
Total pleural-effusion component volume across both sides
pleural effusion
Assign 0 mL when no fluid component is recorded.
100.00
Distal esophagus area (mm 2 )
Largest axial cross-section of the esophagus mask within its lowest 60 mm
esophagus
Locate the lower boundary at the lowest slice with at least 20 mm 2 of esophagus.
99.99
Table 8: Image measurements and coverage across our training, development, and test sets in CT-RATE.
Appendix figures & tables7 assets
Supplementary material from the paper’s appendix.
Appendix
Report model
Changed decisions
Held-out Δ CE-F1
Held-out Δ GREEN
Edits
SelfCue-KD
0
+11.55→+11.55
+0.19→+0.19
6,390→6,390
NV-Reason-CT
2
+0.85→+00.85
+0.46→+0.47
1,120→1,128
Appendix
Table 9: Development estimates before and after restricting condition simplification to learning folds.
Table 10: Full metric breakdown on changed reports. GREEN components are mean counts per report; attribute groups use reports with relevant questions.
Model
Precision
Recall
CE-F1
CRG
AUROC
Image classifiers
FlexiCT
57.26
67.02
61.22
54.77
87.02
HLIP
48.19
64.71
54.16
51.11
82.89
ASAP
46.80
69.98
55.38
52.26
83.29
Three-classifier mean
53.54
68.86
59.73
54.47
86.52
SelfCue-KD
Appendix
Table 11: Classifier and report performance on 1,564 test scans. Precision, recall, CE-F1, and AUROC are macro-averaged over the 18 abnormalities.
Target abnormality
Measurement and cutoff
Source and supporting text
Aortic dilation
Ascending aorta diameter ≥40 mm
( Munden et al. 2018 ) : “2 SD above the mean diameter as adjusted for age, sex, and body surface area”. Our shared 40 mm cutoff is adapted from population measurements ( Rogers et al. 2013 ) .
Coronary artery wall calcification
Coronary calcium volume >0 mm 3
( Hecht et al. 2017 ) : “CAC should be evaluated and reported on all noncontrast chest CT examinations”. Presence is mapped to nonzero volume.
Hepatic steatosis
Median liver attenuation ≤40 HU
( Boyce et al. 2010 ) : “moderate-to-severe hepatic steatosis (defined by liver attenuation ≤40 HU)”.
Cardiomegaly
Cardiothoracic ratio ≥0.50
( Muangman et al. 2020 ) : Radiograph criterion: “If the CTR is greater than 0.50, cardiomegaly is assumed in the adult patient”. The CT cutoff “was found to be 0.53”. We apply the radiograph value to CT.
Arterial wall calcification
Aortic wall calcium volume >0 mm 3
( Hecht et al. 2017 ) : “It may be reasonable to evaluate and report thoracic aortic calcification”. Nonzero aortic calcium is our proxy for the broader label.
Appendix
Table 12: Measurement cutoffs and source excerpts for the fixed clinical rubric.
Learning agent / editor agent
CRG
GREEN
CT-FineBench
SelfCue-KD
gpt-oss / gpt-oss
47.52→51.91
50.23→49.64
36.07→41.38
Sonnet / gpt-oss
45.40→51.99
50.43→49.99
29.10→41.28
Sonnet / Sonnet
45.39→52.03
50.44→50.05
29.07→41.29
NV-Reason-CT
gpt-oss / gpt-oss
54.69→54.94
45.60→45.93
45.23→44.70
Appendix
Table 13: Revision scores at learning iterations 1 and 10, shown from left to right.
Table 14: Draft and revised scores for five sampling seeds. A separate rule bank is learned for each seed.
Vessel
Added
Reference pairs
MAE (mm)
SelfCue-KD
Ascending aorta
240
62
2.3
Aortic arch
0
0
–
Descending aorta
260
12
2.7
Main pulmonary artery
17
5
1.0
NV-Reason-CT
Appendix
Table 15: Added diameters and agreement with reference reports. MAE uses additions with matching reference measurements.
Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland · ETH AI Center, Zurich, Switzerland · Department of Computer Science, ETH Zurich, Zurich, Switzerland +5