cs.CVNov 21, 2026

OKB-CFM: Observation-Keyed Barycentric Conditional Flow Matching for Unpaired Sparse-to-Dense Cardiac Shape Completion

Authors: Kangneng Zhou, Shuang Song, Yitian Zhao, Dian Song, Yujia Wang, Xinghua Zhang, Li Wang, Xi Li, 

Organizations: School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China · Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Zhejiang 315201, China · Medical School of Chinese Peoples Liberation Army General Hospital, Beijing 100853, China · Department of Radiology, First Medical Center of the Chinese Peoples Liberation Army General Hospital, Beijing 100083, China · 

Abstract

Completing cardiac segmentations from sparse cine magnetic resonance labels is challenging because acquired planes do not uniquely determine the underlying anatomy and patient-matched dense annotations are rarely available. We propose observation-keyed barycentric conditional flow matching for completion between clinically unpaired cohorts. Independently trained variational autoencoders represent sparse observations and dense shapes. A fixed memory associates simulated sparse keys with their source dense encodings, enabling candidate retrieval within the sparse latent space. A matching network aggregates the retrieved values into a query-dependent barycentric endpoint, toward which an endpoint-conditioned flow transports the sparse encoding. Individual candidate values provide alternative completion endpoints. On 327 real unpaired inputs, the method obtains encoder-feature Fréchet and squared maximum mean discrepancy scores of 7.93 and 2.02 after scaling by 10,000 and 10,000,000, respectively, corresponding to reductions of 47.0% and 94.2% relative to contrastive unpaired translation. On a 34-file simulated test partition, evaluation against dense-VAE-reconstructed references yields a five-class mean Dice of 0.889, squared Chamfer distance of 6.15 square voxels, 95th-percentile surface distance of 3.88 voxels, and average symmetric surface distance of 1.50 voxels. These results characterize cohort-level feature agreement, observed-label consistency, and reconstruction under the stated reference construction. By complementing routine cine-based functional assessment with inferred multi-chamber anatomical context, this framework provides a basis for investigating how chamber morphology and spatial relationships relate to cardiac function.

Figures & tables

Explore similar work

Aug 20, 2026

A Strong Linear Baseline for Whole-Heart Cardiac Shape Completion on CT, with an Open Eleven-Structure Statistical Shape Model

Public cardiac cohorts annotate different subsets of the heart, so shapes from separate sources cannot be pooled without shared correspondence. Among released cardiac shape resources, none we identified carries the atrial appendage, pulmonary veins, and caval stumps as separate blocks in one mesh. Completion benchmarks also compare deep models against a least-squares projection onto shape modes, not the conditional estimator the same fitted model implies. We release an eleven- structure cardiac computed-tomography (CT) statistical shape model, built from 383 automatically labelled cases in 11 571-vertex correspondence, and compare completion estimators under one frozen internal split and endpoint. On a 76-case internal list held out from fitting, a closed-form conditional-Gaussian estimator reconstructed the missing non-chamber structures at 3.717 mm mean per-vertex error, averaged equally over one, three, five, and nine observed structures. A five-refit mask-conditioned graph variational autoencoder reached 5.248 mm and nearest-neighbour retrieval 8.931 mm. The paired difference was 1.531 mm (95% confidence interval 1.384 to 1.711), and the ordering held in a raw-coordinate sensitivity arm. Expert manual labels exist for 58 external CT cases, but our registered reference is close enough to score only five structures. There the closed-form estimator again had lower average surface distance, 95th-percentile Hausdorff distance, and Chamfer error for both completed atria. On a second public benchmark of 20 cases the reference was close enough for three of four completed structures, and the same ordering held there. Four structures have no expert reference. The released model and its completion operator support cohort-unification research on aligned CT, not clinical use.
Sep 15, 2025

End-to-End 4D Heart Mesh Recovery Across Full-Stack and Sparse Cardiac MRI

Reconstructing cardiac motion from CMR sequences is critical for diagnosis, prognosis, and intervention. Existing methods rely on complete CMR stacks to infer full heart motion, limiting their applicability during intervention when only sparse observations are available. We present TetHeart, the first end-to-end framework for unified 4D heart mesh recovery from both offline full-stack and intra-procedural sparse-slice observations. Our method leverages deformable tetrahedra to capture shape and motion in a coherent space shared across cardiac structures. Before a procedure, it initializes detailed, patient-specific heart meshes from high-quality full stacks, which can then be updated using whatever slices can be obtained in real-time, down to a single one during the procedure. TetHeart incorporates several key innovations: (i) an attentive slice-adaptive 2D-3D feature assembly mechanism that integrates information from arbitrary numbers of slices at any position; (ii) a distillation strategy to ensure accurate reconstruction under extreme sparsity; and (iii) a weakly supervised motion learning scheme requiring annotations only at keyframes, such as the end-diastolic and end-systolic phases. Trained and validated on three large public datasets and evaluated zero-shot on additional private interventional and public datasets without retraining, TetHeart achieves state-of-the-art accuracy and strong generalization in both pre- and intra-procedural settings. Code and dataset is available at https://github.com/Scalsol/TetHeart.
Oct 13, 2026

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.