Hospitals often update a deployed risk model by adding a data source, such as laboratory results, that only some patients have. Work on safe model updates assumes fixed inputs and so ignores patients who lack the new data. The update has no new measurements for them, yet their rank can change, and a sick patient not yet tested can drop off an alert list. We split rank-based compatibility by data availability and pair it with error correction and alert-list effects. We compared each update with ordinary retraining on the old inputs, predicting ICU admission or death and hospital admission, on 78,475 emergency department visits from MC-MED and, in a pre-registered replication, 100,000 stays from MIMIC-IV-ED at a second hospital. Radiograph report text gave no detectable gain and almost no extra re-ranking. Laboratory results improved prediction but, at both hospitals and with linear or tree models, pushed patients without labs down alert lists; linear updates also reshuffled them more than retraining did, without ranking them better. A top-20% admission list caught 4.2% of admitted patients without labs after the update, against 18.8% after retraining (second hospital: 4.9% against 22.6%), while catching more patients overall. This held for list sizes from 5% to 50% and in every patient group we checked, despite better measured calibration. Separate alert thresholds for patients with and without labs restored most or all of their catch rate at both hospitals at almost no cost. Teams should check these patients before deploying such an update.
Figures & tables
Fig. 1: Test pairs grouped by who has the added data. For linear updates, UU-pair swaps reflect re-estimated weights on old features.
Exp.
Added data
Outcome, design
AUROC
Flipped (%)
Extra flips (pp)
Δ AUROC ∅
retrain → update
retrain
update
1
Radiograph text
ICU/death, random
0.888 → 0.888
3.5
3.5
+0.04 [+0.02, +0.05]
− 0.0001 [ − 0.0003, 0.0000]
2
Lab results
ICU/death, random ∗
0.868 → 0.885
6.0
7.2
+1.18 [+0.60, +1.76]
− 0.0042 [ − 0.0106, +0.0023]
2
Lab results
ICU/death, time-ordered
0.852 → 0.882
1.3
6.4
+5.05 [+0.75, +9.36]
− 0.0551 [ − 0.0924, − 0.0177]
2
Lab results
ICU/death, boosting
0.870 → 0.891
8.7
9.7
+1.00 [ − 0.26, +2.25]
− 0.0095 [ − 0.0228, +0.0037]
3
Lab results
admission, random ∗
0.767 → 0.802
4.0
5.7
+1.71 [+1.09, +2.33]
− 0.0043 [ − 0.0077, − 0.0009]
TABLE II: Patients without the added data: retrain → update; differences mean [95% CI]. ∗ Pre-specified.
Fig. 2: Flipped UU pairs, retrain vs. update; one line per repetition. ∗ Pre-specified.
Fig. 3: Experiment 3: admitted visits caught by top- k % lists (mean, 95% CI). Dotted: random list.
Exp.
Mitigation
Δ AUROC
Δ Flipped (pp)
Δ Fixed (pp)
Δ Caught (pp)
1 (radiograph text)
RBC [ 2 ]
− 0.0005 [ − 0.0025, +0.0015]
− 1.96 [ − 2.31, − 1.62]
− 11.6 [ − 13.7, − 9.6]
–
Routing
− 0.0093 [ − 0.0123, − 0.0064]
− 3.55 [ − 3.97, − 3.13]
− 32.7 [ − 36.2, − 29.2]
–
2 (labs, ICU/death)
RBC [ 2 ]
− 0.0033 [ − 0.0060, − 0.0006]
− 3.58 [ − 4.65, − 2.51]
− 6.7 [ − 9.7, − 3.6]
− 0.2 [ − 2.8, +2.4]
Routing
− 0.0009 [ − 0.0020, +0.0002]
− 7.17 [ − 8.50, − 5.84]
− 25.6 [ − 31.9, − 19.4]
+2.4 [ − 1.3, +6.2]
3 (labs, admission)
RBC [ 2 ]
− 0.0124 [ − 0.0131, − 0.0117]
− 3.79 [ − 4.23, − 3.35]
− 8.6 [ − 9.5, − 7.7]
+7.1 [+6.6, +7.6]
Routing
− 0.0040 [ − 0.0046, − 0.0034]
− 5.72 [ − 6.27, − 5.18]
− 14.2 [ − 15.4, − 13.1]
+9.7 [+8.9, +10.5]
TABLE VI: Mitigations minus the plain update, mean [95% CI]; bold: CI excludes 0. All in pp except AUROC.
Models are updated repeatedly, and an update that looks better on validation data but not on new data is a false improvement that can misguide clinical decisions. The naive rule accepts every positive validation gain and is optimistic when the same data choose and judge the update. BRIDGE is a model-agnostic acceptance gate that decides each update from predictions and the available labels, with fixed settings. Each fold of the data judges the update chosen on the other folds (cross-fitting) to reduce selection bias; acceptance requires the gain's lower bootstrap bound to exceed a margin. The four settings are (A) 11 new datasets, (B) synthetic tasks, (C) 12 retrospective clinical tasks, and (D) 39 supporting datasets. The false-improvement rate falls from 19.1% (naive) to 1.1% (BRIDGE) in (A), 20.7% to 1.7% (B), 20.0% to 0% (C), and 12.5% to 0.5% (D); every 95% confidence interval of the reduction over datasets or tasks excludes zero (not over the clinical sources). An equal-size random draw from the naive acceptances contains more false improvements in (A)-(E) (post hoc, p<0.001). On the OpenML collection (E) of 14 new datasets, the false-improvement rate falls from 25.6% to 1.0%. BRIDGE removes 97% to 100% of the false improvements that the naive rule accepts, and its mean gain per deployed update is 1.8 to 3.1 times the naive rule's. The 95% upper bound on the false-improvement rate is below 5.5%: formal in (B) for independent tasks (3.56%), and conditional on the real data tested (0.33% to 5.40%).
Dwi Sunaryono
Department of Informatics, Faculty of Intelligent Electrical and Informatics Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Missing ratings can overturn a personalized model's current prediction. For completed models with additive response scores, exact worst case bounds check all missing assignments without changing the current predictor. We evaluate this audit retrospectively in two self-triage cohorts, 108 clinicians rating three simulated psychiatric interviews, and 126 counseling demonstrations annotated by ten experts. Under shared random half histories, Fisher adaptation based on observed ratings reduces log loss relative to response frequency by 0.1071 nats in the clinician audit (95% CI [0.0867,0.1261]) and 0.0223 in counseling (95% CI[0.0121,0.0321]). The counseling test excludes target experts and source videos from training. Certification covers 5.4% and 10.5% of targets; fixed width acquisition raises coverage to 13.7% and 28.6% at the same budgets. With weights and responses held fixed, the observed-rating update also has lower loss than an affine partial update while certifying exactly the same evaluated targets. The certificate establishes agreement with the completed model, not correctness or stability at intermediate updates. These rating tasks test the method; clinical usefulness remains untested.
Priyanka Siddappa, Muntaqim Ahmed Raju, Shifat Haider Al Amin +1
University of Massachusetts Lowell, Lowell, MA 01854, USA
Understanding how a prediction model will perform in a new environment before deployment is essential to preventing harm when algorithms inform decision-making. Two common sources of model performance degradation are (i) covariate shift, where the target covariate distribution differs from the source, and (ii) selective labels, where the observability of outcomes depends on historical decisions. We study pre-deployment model evaluation under the joint presence of covariate shift and labeling of outcomes selectively based on observed features. In particular, we present a double machine learning procedure for estimating the target risk of an arbitrary black-box prediction model under a general loss function. We show identification of this estimand under standard assumptions and derive a bias-corrected estimator based on the influence function of the target risk. Finally, we evaluate our estimator through experiments using the eICU electronic health records database, showing that it tracks the true target risk more accurately than methods that address either selective labels or covariate shift alone, as well as baselines that combine standard plug-in approaches.
Annie Ulichney, Amanda Coston
Department of Statistics, University of California, Berkeley