cs.CVNov 22, 2026

A colour-marker tracker for pose estimation of slender surgical instruments: vision-language-model-guided adaptive colour calibration

Authors: Jaesung Hong, Dong Won Lee

Organizations: R&D Center, A4LAB Inc., Gumi, Republic of Korea · Department of Robotics and Mechatronics Engineering, DGIST, Daegu, Republic of Korea · Department of Otorhinolaryngology–Head and Neck Surgery, Daegu Catholic University, Daegu, Republic of Korea

Abstract

Slender surgical instruments need small, narrow markers for camera-based pose estimation. A colour-stripe marker fits this requirement, but its colours in the image drift from the design values with lighting, printing and camera settings. Because the colours can only be corrected after the marker has been found, methods that rely on the design colours face a circular problem. We propose vision-language-model (VLM)-based adaptive colour calibration and compare it with two rule-based methods, which re-measure the colours from detections made with the design colours: Initial colour update does so once after tracking starts, and Colour adaptation continuously during tracking. VLM guidance uses a fine-tuned VLM to find the markers without relying on the design colours and builds the colour profile from their pixels. Recall/F1 (%) for Initial colour update, Colour adaptation and VLM guidance were 92.0/95.7, 87.8/93.3 and 98.2/99.1 on 672 synthetic image pairs; 51.3/67.2, 48.8/65.0 and 83.8/87.0 on eight degraded laboratory videos; and 38.9/55.2, 19.7/29.7 and 100/100 on a surgical-robot (da Vinci) video with strongly shifted colours. In that video the rule-based methods never found the purple/cyan marker, whereas VLM guidance found all 234 markers with no false positives. In a simulation, the hue boundary between the two stripes moved by less than 0.1 pixel for exposure gains of 0.5-2.0, compared with 2.9-4.0 pixels for a boundary found with a fixed brightness threshold. When the degradation is mild, the rule-based methods, which need no training and no GPU, are sufficient. When the colours change greatly, the gain comes from a VLM-guided candidate search that does not rely on the design colours. Combining colour-stripe markers with adaptive colour calibration enables tracking of slender surgical instruments with small markers.

Explore similar work

Oct 19, 2026

Curvature as a Baseline: Monocular Pose Measurement of Cylindrical Objects with Dual Colour Stripe Markers

Thin cylindrical objects offer little space for planar markers. We propose a dual-colour-stripe marker that uses the known curvature of an object to improve pose measurement with a single camera. The boundary between two colours provides a long centre line, while dots and printed edges supply features at different depths. We analyse how this depth separation improves the estimation of rotation about the cylinder axis, or roll. For a camera-facing marker at 15 cm, the Cramér-Rao lower bound on roll standard deviation is 2.00°for a flat marker, 0.38°for a single curved marker and 0.21°for a wrap-around marker. Monte Carlo roll RMS errors are within about 10% of the corresponding standard-deviation bounds. A first-order relation connects the sagitta of the curved marker to the roll sensitivity provided by a stereo baseline. The analytical and simulation results explain how curvature improves monocular measurement and provide a basis for designing marker geometry.
Mar 26, 2026

Training-free Detection and 6D Pose Estimation of Unseen Surgical Instruments

Purpose: Accurate detection and 6D pose estimation of surgical instruments are crucial for many computer-assisted interventions. However, supervised methods lack flexibility for new or unseen tools and require extensive annotated data. This work introduces a training-free pipeline for accurate multi-view 6D pose estimation of unseen surgical instruments, which only requires a textured CAD model as prior knowledge. Methods: Our pipeline consists of two main stages. First, for detection, we generate object mask proposals in each view and score their similarity to rendered templates using a pre-trained feature extractor. Detections are matched across views, triangulated into 3D instance candidates, and filtered using multi-view geometric consistency. Second, for pose estimation, a set of pose hypotheses is iteratively refined and scored using feature-metric scores with cross-view attention. The best hypothesis undergoes a final refinement using a novel multi-view, occlusion-aware contour registration, which minimizes reprojection errors of unoccluded contour points. Results: The proposed method was rigorously evaluated on real-world surgical data from the MVPSP dataset. The method achieves millimeter-accurate pose estimates that are on par with supervised methods under controlled conditions, while maintaining full generalization to unseen instruments. These results demonstrate the feasibility of training-free, marker-less detection and tracking in surgical scenes, and highlight the unique challenges in surgical environments. Conclusion: We present a novel and flexible pipeline that effectively combines state-of-the-art foundational models, multi-view geometry, and contour-based refinement for high-accuracy 6D pose estimation of surgical instruments without task-specific training. This approach enables robust instrument tracking and scene understanding in dynamic clinical environments.
Jul 14, 2026

Streamlining stereo differentiable rendering for marker-free real-time tracking of surgical robots

Purpose: Marker-based tracking of surgical robots is occlusion-prone in cluttered operating rooms. We evaluate stereo differentiable rendering for marker-free, real-time robot pose tracking, potentially improving safety, reducing setup time, and enabling multi-robot interaction. Methods: We extend the markerless pose estimation framework roboreg to online dynamic tracking via (i) sequential optimisation that propagates pose estimates across frames with motion-adaptive hyperparameter tuning, and (ii) CUDA stream parallelisation of segmentation and optimisation, combined with CUDA-graph accelerated segmentation. We evaluate on 38 unobstructed and 5 occluded displacement sequences with static start/end ground-truth calibrations and dynamic marker-based reference tracking. Results: We achieve real-time 1080p tracking at 30 fps (up from 14 fps for vanilla roboreg), matching the camera frame rate. Accuracy reaches 1.7 cm / 0.6 deg against static ground truth and 1.2 cm mean 3D error over 27,460 frames against the marker-based reference (1.53 cm over 1,242 occluded frames). Our method outperforms FoundationPose by 11% in dynamic estimation (63% under occlusion) and 250% in static estimation, with 6x faster inference. Conclusions: Stereo differentiable rendering enables real-time, high-resolution marker-free surgical robot tracking, on par with marker-based approaches and surpassing foundation-model baselines.