cs.CYNov 23, 2026

Leveraging Fast Healthcare Interoperability Resources (FHIR) for the Exchange of Wearable Inertial Sensor Data: Design and Development Study

Authors: Gabriela Ciortuz, Joshua Wiedekopf, Hannes Ulrich, Hawzhin Hozhabr Pour, Sebastian Fudickar

Organizations: Institute of Medical Informatics, University of Luebeck, Lübeck, Germany · Section for Clinical Research IT, Institute of Medical Biometry and Statistics, University of Luebeck & University Hospital Schleswig-Holstein, Lübeck, Germany · Department of Medical Informatics, Institute for Community Medicine, University Medicine Greifswald, Greifswald, Germany · Fraunhofer Research Institution for Individualized Medical Technology and Engineering (IMTE), Lübeck, Germany

Abstract

Continuous monitoring with wearables can support the assessment of frailty, functional decline, and movement disorders, but raw inertial measurement unit (IMU) recordings are typically stored in proprietary files that electronic health records cannot exchange or interpret. HL7 Fast Healthcare Interoperability Resources (FHIR) standardizes health data exchange, yet existing FHIR profiles for personal health devices target spot measurements and short waveforms, not long multichannel motion recordings with their recording context and activity labels. We present WHIR (Wearable Health Interoperable Recordings), a FHIR R5-based information model and implementation guide for wearable IMU recordings. Metadata requirements were derived from a review of 23 published human activity recognition datasets and formalized in a FHIR-independent information model, which was then mapped to FHIR R5 and authored in FHIR Shorthand. Raw signals are kept in files referenced through DocumentReference resources, so that FHIR holds the metadata and activity labels. Terminology reuses SNOMED CT, LOINC, and ISO/IEEE 11073 concepts wherever available. The implementation guide defines 9 profiles, 4 extensions, 10 code systems, and 15 value sets; all artifacts and 67 example instances passed the conformance checks of the HL7 FHIR IG Publisher without errors. Two use cases, machine learning training data and automated home-based geriatric assessment, were implemented as conformant example instances, and we compare the model with the HL7 Personal Health Device Implementation Guide. WHIR provides a FHIR R5-conformant representation of wearable IMU recordings together with device metadata, sensor placement, and time-aligned activity labels, covering concepts that the Personal Health Device Implementation Guide does not address. The implementation guide and its sources are openly available for reuse and extension.

Explore similar work

May 4, 2026

HARMES: A Multi-Modal Dataset for Wearable Human Activity Recognition with Motion, Environmental Sensing and Sound

With each sensing modality exhibiting inherent strengths and limitations, multi-modal approaches for wearable Human Activity Recognition (HAR) are becoming increasingly relevant -- particularly for recognizing Activities of Daily Living (ADLs), where individual modalities often produce ambiguous signals for similar or complex activities. This work introduces HARMES, a multi-modal wearable dataset combining three wrist-recorded modalities: motion sensing via an Inertial Measurement Unit (IMU), atmospheric environmental sensors (humidity, temperature, and pressure), and audio. Collected from 20 participants performing household activities in their own homes, HARMES totals over 80 hours of recorded data, with approximately three hours of labeled activity data per participant across 15 ADL classes. To the best of our knowledge, HARMES is the first dataset to combine this particular sensor trio, and it is nearly six times larger than the previously largest wrist-inertial-acoustic HAR dataset. In an extensive benchmark, we evaluate cross-subject generalization and conduct an ablation study revealing that modality contributions are activity-dependent and can provide complementary value, particularly for activities that are ambiguous from motion data alone. HARMES is freely available at Zenodo, alongside example code for loading the dataset and training models on GitHub.
Jun 25, 2026

OpenMHC: Accelerating the Science of Wearable Foundation Models

Mobile and wearable devices offer an unprecedented opportunity for continuous, passive health monitoring and active health coaching. However, the largest wearable datasets are proprietary, and leading wearable foundation models trained on them are rarely open weight or include reproducible training code. To accelerate open science in wearable health, we introduce OpenMyHeartCounts (OpenMHC), the largest and most comprehensive wearable health dataset broadly accessible to qualified researchers, alongside open-source implementations and weights for recent wearable foundation models. Derived from over a decade of data collected through the My Heart Counts study app, OpenMHC comprises over 67M participant-hours of wearable recordings across up to 19 sensor channels (e.g., step count, heart rate, sleep, workouts) and up to 170 health, lifestyle, mood, and behavioral variables from 11,894 participants. Furthermore, we establish a benchmark for standardized evaluation across three tasks: (1) health and behavioral outcome prediction, (2) multivariate data imputation, and (3) time-series forecasting. Benchmarking classical methods alongside recent wearable and time-series foundation models, we find that while foundation models perform strongly, carefully tuned classical baselines like XGBoost remain highly competitive. By uniting broad-access wearable data with open code and model weights, OpenMHC provides a framework needed to drive reproducible advances in wearable health AI.
Aug 16, 2026

Rotation-Invariant Multi-IMU Activity Recognition under Independent Per-Location Orientation Shifts

Human Activity Recognition (HAR) with self-administered wearables, such as at-home rehabilitation and exercise monitoring, often requires reattaching inertial measurement units (IMUs) across sessions. In multi-IMU settings, this can induce independent orientation offsets across body locations, a deployment shift that conventional scalar HAR models do not structurally handle. Existing remedies rely on rotation augmentation, whose robustness depends on sampled transformations, or calibration and orientationnormalization pipelines requiring additional reference-frame assumptions or explicit procedures. We present Truly Rotation-Invariant HAR (TRI-HAR), a rotation-invariant framework that makes robustness to independent per-location IMU orientation offsets a structural model property. TRI-HAR reshapes accelerometer and gyroscope streams into triaxial vectors, applies a shared SO(3)-equivariant backbone and invariant projection to each IMU location, and fuses the resulting invariant features for activity classification. Across four multi-IMU benchmarks, TRI-HAR preserves macro-F1 under fixed independent per-location SO(3) rotations and outperforms rotation-augmented baselines under this target shift without requiring rotational augmentation.