Surgical resection planning centers on generating executable resection surfaces from anatomical evidence and operative constraints. Medical multimodal foundation models enable anatomical understanding, and segmentation models predict resection regions, but neither translates these capabilities into explicitly constrained, executable resection surfaces. We present GeoSurge, an anatomy-grounded framework that combines mask-derived metrics with structure-aware point-cloud tokens to generate executable, editable resection surfaces. To make resection geometry learnable and editable, GeoSurge maps actions to parametric geometry through a surface-action grammar. Using this grammar, anatomy-oriented and tumor-centered templates generate candidates, which are filtered by hard constraints and semantic deduplication. Training supervision is then derived from candidate-expert geometric agreement and independently recomputed feasibility metrics. At inference, the reasoner uses patient evidence and surgical requirements to select or revise an action, which an independent geometry engine subsequently materializes and verifies. GeoSurge achieves the best overall scores on DeepTumour Liver and CRLM-QA, improving the constraint satisfaction rate from 73% to 100% on CRLM and from 56% to 99% on GeoSurge-Bench.
Figures & tables
Figure 1: Existing methods and GeoSurge for executable liver-resection planning. (a) Segmentation methods predict masks without explicit anatomical constraints. (b) 3D medical VLMs reason about anatomy but lack actionable geometry. (c) GeoSurge generates anatomically constrained, executable surfaces to support surgical planning.
Figure 2: GeoSurge pipeline. (1) Patient representation. CT-derived masks produce verifiable facts and structure-aware point embeddings. (2) Candidate compilation. An action grammar generates editable surfaces, followed by virtual rollout, hard gating, deduplication, and Top- K selection. (3) Reasoning and verification. Conditioned on the request and patient evidence, the reasoner selects or revises an action, which an independent geometry engine materializes and verifies.
Model
Param.
DeepTumour Liver
CRLM-QA
Quant.
Lesion
Spatial
Tissue
Mean
Select.
Complete
Safety
Pref.
Mean
Rand
–
0.25
0.39
0.29
0.40
0.34
0.41
0.69
0.17
0.17
0.36
Qwen3-VL
30B-A3B
0.32
0.51
0.24
0.36
0.31
0.38
0.75
0.21
0.28
0.40
Qwen2.5-VL
7B
0.26
0.24
0.41
0.34
0.31
0.35
0.71
0.09
0.16
0.33
MedGemma
27B
0.26
0.45
0.57
0.30
0.40
0.36
0.75
0.24
0.27
0.41
HuatuoGPT-Vision
34B
0.28
0.65
0.32
0.35
0.40
0.42
0.72
0.29
0.31
0.44
Table 1: Comparison results on the DeepTumour Liver and CRLM-QA benchmarks. The “Rand” row reports random-guess accuracy for each task. Best results are bold and second-best results are underlined.
Method
CRLM
GeoSurge-Bench
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
LIZARD-RandLA-Net
0.57
0.55
0.00
0.98
0.42
0.61
0.00
0.78
nnU-Net
0.58
0.37
0.00
0.90
0.42
0.45
0.01
0.70
STU-Net
0.66
0.17
0.07
0.90
0.37
0.27
0.01
0.60
Qwen3-VL-30B-A3B+ESAC
0.58
0.23
0.73
1.00
0.45
0.17
0.56
0.99
Qwen2.5-VL-7B+ESAC
0.29
0.36
0.50
0.57
0.11
0.29
0.19
0.25
Table 2: Surface-planning results on the CRLM and GeoSurge-Bench benchmarks. Upper rows are geometry baselines; lower rows use ESAC to construct and screen a shared action set and materialize editable Bézier surfaces. Both GeoSurge rows use K=16 /cap 0.80 (post hoc). † Hidden-reference one-edit oracle; rankings exclude this row. Bold and underline mark best and second-best results.
Figure 3: Qualitative planning comparison on (a) CRLM case 1103 and (b) an anonymized GeoSURGE-Bench case. Columns show the original anatomy, reference resection, LIZARD-RandLA-Net, nnU-Net, STU-Net, direct 32D prediction, Qwen2.5-VL+ESAC, 3DMedAgent -30B+ESAC, HuatuoGPT-Vision+ESAC, and GeoSurge .
Variant
Components
CRLM
GeoSURGE-Bench
FT
3D
Cand.
Gate
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
Qwen2.5-VL-7B
0.00
0.44
0.00
0.00
0.00
0.32
0.00
0.00
Direct prediction
✓
✓
0.61
0.39
0.27
1.00
0.46
0.58
0.16
1.00
Random Top- K
✓
✓
✓
0.60
0.32
0.56
1.00
0.48
0.41
0.54
1.00
Metric only
✓
✓
0.55
0.21
1.00
1.00
0.47
0.17
0.96
1.00
Facts only
✓
✓
✓
0.61
0.19
1.00
1.00
0.52
0.17
0.99
1.00
Table 3: Ablation results on CRLM and GeoSURGE-Bench; terms are defined in text; bold/underline mark best/second-best.
Figure 4: Post-hoc sensitivity on 30 CRLM cases. (a) Dice statistics across Gate-Top- K shortlist sizes (Q1: first quartile). (b) Failure-free fraction beyond observed segmentation error (coverage-aware Dice ≥0.35 at every preceding dose; unadjusted 95% paired-case bootstrap CIs).
Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dimensional CT volume. Existing tools often handle these steps separately, while language models cannot reliably compute physical measurements from CT. To provide an integrated workflow, we present VoxelSage, a multi-modal system for two- and three-dimensional visualization, liver-tumor analysis, and preoperative resection planning. Its dual-port architecture separates language-model orchestration from image computation: Port A interprets requests and selects skills, while Port B applies them to CT volumes and segmentation masks and returns structured results. Keeping physical measurements in Port B prevents the LLM from computing them directly and reduces the risk of fabricated numerical results. Eight built-in skills support quantitative analysis, visual evidence generation, three-dimensional reconstruction, segmentation refinement, and sequential resection planning; user-defined skills can extend these functions. For sequence planning, a behavior-cloned neural ranker orders candidate resection targets, while a simulator-based shield checks them against predefined constraints. Across 256 unseen simulator scenes, this approach reduced mean simulated time from 34.274 to 33.388 min (0.886 min, 2.59%) and mean simulated blood loss from 300.847 to 183.852 mL (116.995 mL, 38.89%) relative to a deterministic baseline. These results demonstrate system integration and simulator-level performance, not clinical efficacy or safety. The public implementation is available at https://github.com/ZJUMAI/VoxelSage.
Referring surgical video segmentation requires segmenting a target instrument or tissue region across video frames according to a natural language expression. Recent Segment Anything Model 2 (SAM2) based two-stage methods (e.g., ReSurgSAM2) first ground the referred target in an initial or selected frame, then propagate the selected mask via tracking. Although effective, their performance is highly sensitive to the quality of the initial grounded mask: once an incorrect anchor is selected, subsequent tracking tends to propagate the error. This issue is especially challenging in surgical videos due to visually similar instruments, occlusion, and complex tissue-tool interactions. To address this issue, we propose ReGround-Surg, a lightweight reliability-guided anchor grounding framework to improve SAM2-based referring surgical video segmentation. It first predicts a text-conditioned spatial reliability map from the referring expression and current-frame visual features. The map is then reused in two complementary branches: a Gated Side Adapter enhances expression-relevant visual regions before text-to-vision fusion, while a Reliability-Weighted Vision-to-Text Attention module suppresses off-target visual evidence during prompt-token aggregation. Experiments on Ref-EndoVis17 and Ref-EndoVis18 show consistent improvements over state-of-the-art methods across three evaluation splits with negligible speed reduction. Code is publicly available at https://github.com/JiaxinWen1/ReGround-Surg.
We introduce SurgFormer, a multiresolution gated transformer for data driven soft tissue simulation on volumetric meshes. High fidelity biomechanical solvers are often too costly for interactive use, so we train SurgFormer on solver generated data to predict nodewise displacement fields at near real time rates. SurgFormer builds a fixed mesh hierarchy and applies repeated multibranch blocks that combine local message passing, coarse global self attention, and pointwise feedforward updates, fused by learned per node, per channel gates to adaptively integrate local and long range information while remaining scalable on large meshes. For cut conditioned simulation, resection information is encoded as a learned cut embedding and provided as an additional input, enabling a unified model for both standard deformation prediction and topology altering cases. We also introduce two surgical simulation datasets generated under a unified protocol with XFEM based supervision: a cholecystectomy resection dataset and an appendectomy manipulation and resection dataset with cut and uncut cases. To our knowledge, this is the first learned volumetric surrogate setting to study XFEM supervised cut conditioned deformation within the same volumetric pipeline as standard deformation prediction. Across diverse baselines, SurgFormer achieves strong accuracy with favorable efficiency, making it a practical backbone for both tasks. {Code, data, and project page: available here}
Ashkan Shahbazi, Elaheh Akbari, Kyvia Pereira +7
Department of Computer Science, College of Connected Computing, Vanderbilt University · Vanderbilt Institute for Surgery and Engineering · Department of Biomedical Engineering, Vanderbilt University +1