Surgical resection planning centers on generating executable resection surfaces from anatomical evidence and operative constraints. Medical multimodal foundation models enable anatomical understanding, and segmentation models predict resection regions, but neither translates these capabilities into explicitly constrained, executable resection surfaces. We present GeoSurge, an anatomy-grounded framework that combines mask-derived metrics with structure-aware point-cloud tokens to generate executable, editable resection surfaces. To make resection geometry learnable and editable, GeoSurge maps actions to parametric geometry through a surface-action grammar. Using this grammar, anatomy-oriented and tumor-centered templates generate candidates, which are filtered by hard constraints and semantic deduplication. Training supervision is then derived from candidate-expert geometric agreement and independently recomputed feasibility metrics. At inference, the reasoner uses patient evidence and surgical requirements to select or revise an action, which an independent geometry engine subsequently materializes and verifies. GeoSurge achieves the best overall scores on DeepTumour Liver and CRLM-QA, improving the constraint satisfaction rate from 73% to 100% on CRLM and from 56% to 99% on GeoSurge-Bench.
Figures & tables
Figure 1: Existing methods and GeoSurge for executable liver-resection planning. (a) Segmentation methods predict masks without explicit anatomical constraints. (b) 3D medical VLMs reason about anatomy but lack actionable geometry. (c) GeoSurge generates anatomically constrained, executable surfaces to support surgical planning.
Figure 2: GeoSurge pipeline. (1) Patient representation. CT-derived masks produce verifiable facts and structure-aware point embeddings. (2) Candidate compilation. An action grammar generates editable surfaces, followed by virtual rollout, hard gating, deduplication, and Top- K selection. (3) Reasoning and verification. Conditioned on the request and patient evidence, the reasoner selects or revises an action, which an independent geometry engine materializes and verifies.
Model
Param.
DeepTumour Liver
CRLM-QA
Quant.
Lesion
Spatial
Tissue
Mean
Select.
Complete
Safety
Pref.
Mean
Rand
–
0.25
0.39
0.29
0.40
0.34
0.41
0.69
0.17
0.17
0.36
Qwen3-VL
30B-A3B
0.32
0.51
0.24
0.36
0.31
0.38
0.75
0.21
0.28
0.40
Qwen2.5-VL
7B
0.26
0.24
0.41
0.34
0.31
0.35
0.71
0.09
0.16
0.33
MedGemma
27B
0.26
0.45
0.57
0.30
0.40
0.36
0.75
0.24
0.27
0.41
HuatuoGPT-Vision
34B
0.28
0.65
0.32
0.35
0.40
0.42
0.72
0.29
0.31
0.44
Table 1: Comparison results on the DeepTumour Liver and CRLM-QA benchmarks. The “Rand” row reports random-guess accuracy for each task. Best results are bold and second-best results are underlined.
Method
CRLM
GeoSurge-Bench
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
LIZARD-RandLA-Net
0.57
0.55
0.00
0.98
0.42
0.61
0.00
0.78
nnU-Net
0.58
0.37
0.00
0.90
0.42
0.45
0.01
0.70
STU-Net
0.66
0.17
0.07
0.90
0.37
0.27
0.01
0.60
Qwen3-VL-30B-A3B+ESAC
0.58
0.23
0.73
1.00
0.45
0.17
0.56
0.99
Qwen2.5-VL-7B+ESAC
0.29
0.36
0.50
0.57
0.11
0.29
0.19
0.25
Table 2: Surface-planning results on the CRLM and GeoSurge-Bench benchmarks. Upper rows are geometry baselines; lower rows use ESAC to construct and screen a shared action set and materialize editable Bézier surfaces. Both GeoSurge rows use K=16 /cap 0.80 (post hoc). † Hidden-reference one-edit oracle; rankings exclude this row. Bold and underline mark best and second-best results.
Figure 3: Qualitative planning comparison on (a) CRLM case 1103 and (b) an anonymized GeoSURGE-Bench case. Columns show the original anatomy, reference resection, LIZARD-RandLA-Net, nnU-Net, STU-Net, direct 32D prediction, Qwen2.5-VL+ESAC, 3DMedAgent -30B+ESAC, HuatuoGPT-Vision+ESAC, and GeoSurge .
Variant
Components
CRLM
GeoSURGE-Bench
FT
3D
Cand.
Gate
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
G. Dice ↑
FLR Err. ↓
CCSR ↑
Tumor Rec. ↑
Qwen2.5-VL-7B
0.00
0.44
0.00
0.00
0.00
0.32
0.00
0.00
Direct prediction
✓
✓
0.61
0.39
0.27
1.00
0.46
0.58
0.16
1.00
Random Top- K
✓
✓
✓
0.60
0.32
0.56
1.00
0.48
0.41
0.54
1.00
Metric only
✓
✓
0.55
0.21
1.00
1.00
0.47
0.17
0.96
1.00
Facts only
✓
✓
✓
0.61
0.19
1.00
1.00
0.52
0.17
0.99
1.00
Table 3: Ablation results on CRLM and GeoSURGE-Bench; terms are defined in text; bold/underline mark best/second-best.
Figure 4: Post-hoc sensitivity on 30 CRLM cases. (a) Dice statistics across Gate-Top- K shortlist sizes (Q1: first quartile). (b) Failure-free fraction beyond observed segmentation error (coverage-aware Dice ≥0.35 at every preceding dose; unadjusted 95% paired-case bootstrap CIs).
Department of Computer Science, College of Connected Computing, Vanderbilt University · Vanderbilt Institute for Surgery and Engineering · Department of Biomedical Engineering, Vanderbilt University +1