quant-phNov 24, 2026

Quantum kernels on breast data: concentration, surrogates, and two ways an advantage gets manufactured

Authors: Rana Saad, Achraf Toufah, Moulay Youssef El Hafidi

Organizations: Qanary Inc.

Abstract

Quantum-kernel advantage claims on breast data are usually a single number: one quantum arm, one comparator, one test split. We asked what that number measures once the full comparator set and selection history are visible. We report three active benchmarks, all exact classical statevector simulations of 8-qubit fidelity kernels with no quantum component in the inference path: a sample-efficiency sweep on Wisconsin Diagnostic Breast Cancer at ten training-set sizes; raw-versus-processed arms on 1,200 M-SYNTH simulated mammograms with a matched closed-form dequantisation surrogate, five classical methods at the same input and eleven kernel families; and a 30-seed selection-inflation measurement on BreastMNIST. A CMMD D1 clinical arm is withdrawn as a result arm because its frozen splits leak the label through patient serial order, a defect reported in a separate study; it is retained only as a worked example. All three active arms are negative. On M-SYNTH raw an apparent +0.1736 (p = 5.2e-06) against a tuned RBF-SVM falls to +0.0019 (p = 0.937) against a random forest at the same input, and a Laplacian kernel wins on validation. On WDBC, with model selection confined to training data, the quantum kernel is below the selected classical arm at every training-set size, with 2 of 200 paired subsamples ahead. Best-of-30 seed selection adds +0.0210 on BreastMNIST. One result does not fit: at bandwidth 2pi the matched closed-form Gaussian surrogate failed to reproduce the M-SYNTH raw kernel (0.5410 against 0.7045, p = 6.3e-06). Comparator choice and selection each produce effects larger than any quantum-classical difference we measured; we give a reporting standard that removes both.

Figures & tables

Explore similar work

Apr 20, 2026

Benchmarking Quantum Kernel Support Vector Machines Against Classical Baselines on Tabular Data: A Rigorous Empirical Study with Hardware Validation

Quantum kernel methods have been proposed as a promising approach for leveraging near-term quantum computers for supervised learning, yet rigorous benchmarks against strong classical baselines remain scarce. We present a comprehensive empirical study of quantum kernel support vector machines (QSVMs) across nine binary classification datasets, four quantum feature maps, three classical kernels, and multiple noise models, totalling 970 experiments with strict nested cross-validation. Our analysis spans four phases: (i) statistical significance testing, revealing that none of 29 pairwise quantum-classical comparisons reach significance at α=0.05α= 0.05; (ii) learning curve analysis over six training fractions, showing steeper quantum slopes on six of eight datasets that nonetheless fail to close the gap to the best classical baseline; (iii) hardware validation on IBM ibm_fez (Heron r2), demonstrating kernel fidelity r≥0.976r \geq 0.976 across six experiments; and (iv) seed sensitivity analysis confirming reproducibility (mean CV 1.4%). A Kruskal-Wallis factorial analysis reveals that dataset choice dominates performance variance (ε2=0.73\varepsilon^2 = 0.73), while kernel type accounts for only 9%. Spectral analysis offers a mechanistic explanation: current quantum feature maps produce eigenspectra that are either too flat or too concentrated, missing the intermediate profile of the best classical kernel, the radial basis function (RBF). Quantum kernel training (QKT) via kernel-target alignment yields the single competitive result -- balanced accuracy 0.968 on breast cancer -- but with ~2,000x computational overhead. Our findings provide actionable guidelines for quantum kernel research. The complete benchmark suite is publicly available to facilitate reproduction and extension.
Oct 30, 2026

Empirical Evaluation of Quantum Kernel Methods for Classification: A Comparative Study with Classical Kernels

Quantum kernel methods are the most concrete near-term proposal for quantum machine learning on classical data, yet published benchmarks disagree on whether they outperform tuned classical kernels, and the disagreement cannot be resolved from the literature because the comparisons are not protocol-controlled. We argue that the obstacle is one of measurement, not theory: the usual setup fixes the quantum feature map's data scaling while grid-searching the classical kernel's hyperparameters, recomputes nothing per fold, and reports cost in simulator time. We therefore treat the comparison itself as the object of study and impose three controls. The bandwidth is tuned on the same grid budget as the classical γγ, the kernel is recomputed inside every fold from fold-fitted preprocessing, and cost is counted in hardware circuit evaluations. On top of these we run a factorial design of 324 cells in which dimensionality, training size, class separability and data structure are explicit covariates, together with four standard datasets, a shots-versus-gate-noise ablation, and a cost sweep. The dominant effect we measure is not quantum: tuning the feature map's bandwidth is worth 0.120 accuracy on synthetic data and 0.339 on real data, exceeding every quantum-classical difference we observe. Tuned quantum kernels are then statistically indistinguishable from a tuned RBF on all four real datasets. The advantage on synthetic data is confined almost entirely to data generated by the feature map itself, and it shrinks with dimensionality (-0.0045 per qubit) while growing with sample size. Finite sampling costs an order of magnitude more accuracy than gate and readout noise, and a fidelity kernel needs 5×1075\times10^{7} circuits at n = 10,000. Protocol variance is thus sufficient to explain the field's contradictory conclusions.
Apr 27, 2026

Quantum Kernel Advantage over Classical Collapse in Medical Foundation Model Embeddings

We provide evidence of quantum kernel advantage under noiseless simulation in binary insurance classification on MIMIC-CXR chest radiographs using quantum support vector machines (QSVM) with frozen embeddings from three medical foundation models (MedSigLIP-448, RAD-DINO, ViT-patch32). We propose a two-tier fair comparison framework in which both classifiers receive identical PCA-q features. At Tier 1 (untuned QSVM vs. untuned linear SVM, C = 1 both sides), QSVM wins minority-class F1 in all 18 tested configurations (17 at p < 0.001, 1 at p < 0.01). The classical linear kernel collapses to majority-class prediction on 90-100% of seeds at every qubit count, while QSVM maintains non-trivial recall. At q = 11 (MedSigLIP-448 plateau center), QSVM achieves mean F1 = 0.343 vs. classical F1 = 0.050 (F1 gain = +0.293, p < 0.001) without hyperparameter tuning. Under Tier 2 (untuned QSVM vs. C-tuned RBF SVM), QSVM wins all seven tested configurations (mean gain +0.068, max +0.112). Eigenspectrum analysis reveals quantum kernel effective rank reaches 69.80 at q = 11, far exceeding linear kernel rank, while classical collapse remains C-invariant. A full qubit sweep reveals architecture-dependent concentration onset across models. Code: https://github.com/sebasmos/qml-medimage