cs.CVNov 24, 2026

BreathSplat: Grounding One Smooth Motion in the Breathing Phase for 4D Cone-Beam CT

Authors: Sujong Shin, Sang-Il Choi, Kwang Moo Yi

Organizations: 1Dankook University · University of British Columbia

Abstract

Four-dimensional cone-beam computed tomography (4D-CBCT) images the anatomy of a breathing patient, but sees each breathing phase from only a few angles. Breathing, however, is a smooth motion that repeats; it has a phase. Existing methods exploit this either by reconstructing the anatomy as a function of the breathing phase, often through bins, or by estimating smooth dynamic motions in time. Yet none of these grounds one smooth motion in the phase. We thus propose to share projections across breathing phases with splines. Specifically, we represent the 4D volume with dynamic Gaussians whose motion uses B-splines in space and time. We ground the motion state in the respiratory phase, which we read from well-studied conventional surrogates. Projections at the same phase in different breathing cycles then constrain the same anatomy and motion. On simulated lung scans, our method, BreathSplat, outperforms recent dynamic methods in reconstruction and motion accuracy, including those given the ground-truth phase. We further show qualitatively, on two real patient scans, that our method provides clearer reconstructions than the state of the art.

Figures & tables

Appendix figures & tables4 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Aug 4, 2026

Dual-domain U-Nets with embedded back projection operators for motion-resolved 4D CBCT reconstruction

Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts. We propose a deep learning method for motion-resolved 4D CBCT reconstruction from conventional free-breathing scans, without a respiratory signal or explicit projection binning. Our CNN takes free-breathing 3D CBCT projections as input and predicts a static volume at maximum inhalation plus ten displacement vector fields (DVFs) spanning a breathing cycle. The network extends U-Net: the encoder acts on filtered projection stacks, the decoder acts in the volume domain, and skip connections are replaced with non-trainable back-projection functions at multiple resolutions to transfer features between domains. The model is trained on simulated CBCT scans and evaluated on 11 unseen simulated patients and 13 clinical free-breathing scans. Two additional models (60 s and 6 s scans) were evaluated by clinical experts on three and two scans, comparing single phases of our 4D reconstruction to reference 3D SART-TV images for tumor and esophagus visibility. Experts preferred our method for tumor visibility (59% vs. 36% no preference, 5% reference) and esophagus visibility (47% vs. 42%, 11%). On simulated data, image quality matched SART-TV (mean RMSE: -1.19 HU, PSNR: +0.09 dB, SSIM: -0.009) while enabling 4D reconstruction. On clinical scans, our method showed sharper dynamic structures (e.g., diaphragm) and fewer motion streak artifacts than traditional reconstruction. This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Apr 30, 2026

Stop Holding Your Breath: CT-Informed Gaussian Splatting for Dynamic Bronchoscopy

Bronchoscopic navigation relies on registering endoscopic video to a preoperative CT scan, but respiratory motion deforms the airway by 5-20 mm, creating CT-to-body divergence that limits localization accuracy. In practice, this is mitigated through breath-hold protocols, which attempt to match the intraoperative anatomy to a static CT, but are difficult to reproduce and disrupt clinical workflow. We propose to eliminate the need for breath-hold protocols by leveraging patient-specific respiratory modeling. Paired inhale-exhale CT scans, already acquired for planning, implicitly define the patient-specific deformation space of the breathing airway. By registering these scans, we reduce respiratory motion to a single scalar breathing phase per frame, constraining all reconstructions to anatomically observed configurations. We embed this representation within a mesh-anchored Gaussian splatting framework, where a lightweight estimator infers breathing phase directly from endoscopic RGB, enabling continuous, deformation-aware reconstruction throughout the respiratory cycle without breath-holds or external sensing. To enable quantitative evaluation, we introduce RESPIRE, a physically grounded bronchoscopy simulation pipeline with per-frame ground truth for geometry, pose, breathing phase, and deformation. Experiments on RESPIRE show that our approach achieves geometrically faithful reconstruction, over 20x faster training, and 1.22 mm target localization accuracy (within the 3mm clinically relevant tolerances) outperforming unconstrained single-CT baselines. Please check out our website for additional visuals: https://asdunnbe.github.io/RESPIRE/
Oct 13, 2026

Dual-Domain Sparse-View 4D CBCT Reconstruction with Spatial-Temporal Consistency Learning

Four-dimensional cone-beam computed tomography (4D CBCT) provides phase-resolved volumetric images for image-guided radiotherapy. Yet good reconstruction quality usually needs many projections. This increases scan time and radiation dose. We propose STCNet, a sparse-view 4D CBCT reconstruction framework that uses spatial-temporal consistency learning. STCNet reconstructs high-quality images from only 16 projections in each respiratory phase. STCNet integrates physics-driven positional encoding to enforce geometric consistency in the projection domain and introduces temporal encoding in latent space to capture respiratory motion dynamics across phases to capture dynamic respiratory motion across phases. A dual-domain collaborative strategy jointly optimizes both projection and image domains, enhancing structural fidelity and temporal coherence. We tested STCNet on the TCIA-LUNG dataset and a CIRS thorax phantom dataset. STCNet performed better than conventional methods and recent deep learning baselines in image quality, artifact reduction, and structural preservation. On TCIA-LUNG, STCNet reached PSNR values of 33.311, 32.695, and 32.658 dB at phases 2, 5, and 8. The corresponding SSIM values were 0.845, 0.823, and 0.825. On CIRS, STCNet achieved PSNR values up to 36.497 dB and SSIM values up to 0.877. These results support STCNet as a promising framework for low-dose, phase-resolved 4D CBCT reconstruction in image-guided radiotherapy.