BreathSplat: Grounding One Smooth Motion in the Breathing Phase for 4D Cone-Beam CT
Organizations: 1Dankook University · University of British Columbia
Abstract
Four-dimensional cone-beam computed tomography (4D-CBCT) images the anatomy of a breathing patient, but sees each breathing phase from only a few angles. Breathing, however, is a smooth motion that repeats; it has a phase. Existing methods exploit this either by reconstructing the anatomy as a function of the breathing phase, often through bins, or by estimating smooth dynamic motions in time. Yet none of these grounds one smooth motion in the phase. We thus propose to share projections across breathing phases with splines. Specifically, we represent the 4D volume with dynamic Gaussians whose motion uses B-splines in space and time. We ground the motion state in the respiratory phase, which we read from well-studied conventional surrogates. Projections at the same phase in different breathing cycles then constrain the same anatomy and motion. On simulated lung scans, our method, BreathSplat, outperforms recent dynamic methods in reconstruction and motion accuracy, including those given the ground-truth phase. We further show qualitatively, on two real patient scans, that our method provides clearer reconstructions than the state of the art.
Figures & tables
| Body volume | Whole volume | Held-out projection | Motion | ||||||
| Method | PSNR (dB) | SSIM | HFEN | PSNR (dB) | SSIM | HFEN | PSNR (dB) | SSIM | error (mm) |
| Phase-binned FDK [ 11 ] (JOSA A’84) | 24.63 | 0.5350 | 1.4193 | 23.62 | 0.3506 | 1.9280 | 24.16 | 0.7934 | - |
| Phase-binned CGLS [ 16 ] (J. Res. NBS’52) | 29.99 | 0.8095 | 0.7541 | 31.08 | 0.6559 | 0.8808 | 40.19 | 0.9655 | - |
| Static FDK [ 11 ] (JOSA A’84) | 31.59 | 0.9137 | 0.3990 | 33.13 | 0.7352 | 0.4488 | 28.94 | 0.8849 | - |
| Static CGLS [ 16 ] (J. Res. NBS’52) | 36.73 | 0.9324 | 0.3938 | 38.63 | 0.8984 | 0.4167 | 42.23 | 0.9865 | - |
| PICCS [ 7 ] (Med. Phys.’08) | 39.40 | 0.9516 | 0.3172 | 41.38 | 0.9616 | 0.3235 | 48.00 | 0.9968 | - |
| Static Recon. | X 2 -Gaussian [ 55 ] (ICCV’25) | X 2 -Gaussian++ [ 9 ] (GitHub’26) | DIGS [ 18 ] (MICCAI’25) | Fu et al . ∗ [ 14 ] (Med. Phys.’25) | Ours | |
|---|---|---|---|---|---|---|
| TRE (mm) | 4.58 | 4.34 | 4.07 | 3.33 | 3.84 | 1.82 |
| Body PSNR (dB) | - | 39.44 | 40.62 | 39.49 | 41.09 | 44.16 |
| Body volume | Motion | |||
| Variant | PSNR (dB) | HFEN | Edge PSNR (dB) | error (mm) |
| Our full method | 42.18 | 0.1868 | 40.01 | 0.57 |
| Grounding | ||||
| W/o grounding (on acquisition time) | 37.63 | 0.2988 | 34.87 | 0.80 |
| + periodic consistency loss | 37.76 | 0.3367 | 34.30 | 1.04 |
| Accuracy of the phase | ||||
Appendix figures & tables4 assets
Supplementary material from the paper’s appendix.
Appendix
| Parameter | Value | PSNR (dB) | SSIM | HFEN |
|---|---|---|---|---|
| Rank | 2 | 0.03 | 0.0001 | +0.0007 |
| 4 | +0.01 | 0.0001 | 0.0009 | |
| 8 (selected) | 0.00 | 0.0000 | 0.0000 | |
| 16 | 0.36 | 0.0008 | +0.0069 | |
| Temporal control values | 12 | 0.05 | 0.0000 | +0.0007 |
| 24 | 0.02 | 0.0003 | +0.0001 |
Cone-Beam CT
Cone-beam computed tomography (CBCT) reconstructs three-dimensional anatomy from X-ray projections for dental, interventional, and radiotherapy imaging.