Automated Batch-Variable Selection for ComBat-Based Radiomic Harmonization

Authors: Jose Lozano-Montoya, Gemma Urbanos, Carmen Prieto-de-la-Lastra, Emilio Soria-Olivas, Ana Jimenez-Pastor

Organizations: Universitat de València, Valencia, Spain · Research & Frontier in AI Department, Quantitative Imaging Biomarkers in Medicine, Valencia, Spain · Intelligent Data Analysis Laboratory, Universitat de València, Valencia, Spain

Abstract

ComBat harmonizes multicentre radiomic features, but batch variables are usually chosen manually, without a standardized criterion across image acquisition parameters. We propose ParsiComBat, which selects acquisition parameters for ComBat, balancing batch-effect removal against feature-structure preservation and abstaining when technical variation is negligible. ParsiComBat ranks candidate acquisition parameters by batch effect, filters redundancy, and scores sequential ComBat corrections. We evaluated it in three experiments: in simulations, testing whether it recovered a known batch variable and abstained without one; in CT (NSCLC-Radiomics) and MRI (MAMA-MIA) cohorts, comparing batch-effect removal against manufacturer (manual), every feasible parameter (greedy) and AutoCombat; and in clinical prediction, internally and externally. In simulations, ParsiComBat identified the true batch variable in 92.9% of positive trials and abstained in 99.2% of null controls. In CT, correcting for reconstruction kernel reduced mean k-nearest neighbour batch-effect test from 0.276 to 0.032, almost matching greedy correction of six variables. In MRI, correcting for slice thickness and manufacturer reduced it from 0.680 to 0.325, slightly more than manual selection but less than greedy correction of seven variables. Removing technical variation did not improve clinical discrimination: no strategy, including raw features, differed significantly from ParsiComBat in area under the curve. ParsiComBat provides a data-driven framework that removes technical batch effects using minimal acquisition parameters, preserving feature structure and clinical discrimination. It selects variables verifiable against the acquisition protocol and abstains when no correction is needed, supporting transparent, reproducible multicentre radiomics.

Explore similar work

May 14, 2026

How Sensitive Are Radiomic AI Models to Acquisition Parameters?

A main barrier for the deployment of AI radiomic systems in clinical routine is their drop in performance under heterogeneous multicentre acquisition protocols. This work presents a performance-oriented framework for quantifying scan parameter sensitivity of radiomic AI models, while identifying clinically significant parameter regions associated with improved cross-dataset robustness. We formulate a mixed-effects framework for quantifying the influence that clinically relevant acquisition parameters have on models performance, while accounting for subject-level random effects. We have applied our framework to lung cancer diagnosis in CT scans using two independent multicentre datasets (a public database and own-collected data) and several SoA architectures. To evaluate across-database reproducibility, CT parameters have been adjusted using the data collected and tested on the public set. The optimal configuration selected is the current of the X-ray tube >= 200 mA, spiral pitch <= 1.5, slice thickness <= 1.25 mm, which balances diagnostic quality with low radiation dose. These configuration push metrics from 0.79+-0.04 sensitivity, 0.47+-0.10 specificity in low quality scans to 0.90+-0.10 sensitivity, 0.79 +- 0.13 specificity in high quality ones.
Jul 14, 2026

Physically Aware Radiomics Without Interpolation: Disentangling Voxel Geometry and Signal Modification in CT and MRI

Objective: Radiomic texture features are usually computed in voxel-index neighborhoods, implicitly assuming isotropic spatial relationships. In anisotropic images, this can confound voxel geometry with interpolation-induced signal changes. We developed a voxel-spacing-aware radiomic framework that incorporates physical geometry into texture computation without resampling. Approach: We modified PyRadiomics to account for voxel spacing while preserving the native image signal. Four configurations were compared: native non-resampled extraction (NR), isotropic resampling (RS), voxel-spacing-aware extraction (VS), and fake-isotropic preprocessing (FK), in which spacing metadata were overwritten without altering the image array. Experiments included 685 LIDC-IDRI pulmonary nodules and 209 I-SPY2 breast MRI cases, with 196 radiomic descriptors. Robustness was assessed using ICC, within-subject variability, Friedman testing, feature selection, machine learning, a multilayer perceptron, and external validation. Main results: VS showed near-native agreement with NR: median ICC(A,1) was 0.9976 in CT and 0.9984 in MRI. RS produced lower agreement and larger deviations, while FK showed intermediate behavior, confirming that spacing metadata alone can affect radiomic features. Gradient-derived and neighborhood-sensitive descriptors were most affected by preprocessing. VS preserved predictive performance comparable to NR in external CT validation, whereas MRI showed greater variability across preprocessing strategies and classifiers. Significance: Voxel-spacing-aware extraction separates geometric modeling from interpolation-induced signal modification while preserving the native image signal, offering a coherent alternative to isotropic resampling for radiomic analysis of anisotropic CT and MRI.
Jul 30, 2026

Negative controls reveal volume-driven confounding in radiomics and imaging foundation model features

Radiomics and imaging foundation models promise non-invasive biomarkers of tumour biology, yet predictive signatures may reflect tumour volume or acquisition artifacts rather than meaningful image structure. We introduce READII-2-ROQC, an open-source framework that uses volume-preserving negative controls to assess whether radiomic and deep imaging features capture independent spatial signals. READII-2-ROQC generates voxel-perturbed images across tumour, background and whole-image regions using configurable randomization strategies, then compares feature behaviour and model performance between original and control images. Applied to three public cancer imaging cohorts, the framework processed 3,552 tumour volumes and extracted PyRadiomics and foundation-model features from original images and nine matched controls. Reproducing published survival and HPV-status signatures, we show that multiple models retain performance after spatial structure is destroyed, revealing volume-driven or contextual confounding, whereas others show perturbation-sensitive signal. READII-2-ROQC provides a scalable quality-control strategy for developing interpretable, biologically grounded imaging biomarkers and reproducible radiomics workflows.