cs.CVFeb 26, 2026

SKINOPATHY AI: Smartphone-Based Ophthalmic Screening and Longitudinal Tracking Using Lightweight Computer Vision

Authors: S. Kalaycioglu, C. Hong, M. Zhu, H. Xie

Organizations: Toronto Metropolitan University · York University · AIMechatroniX Inc. · DrRobot Inc · 

Abstract

Early ophthalmic screening in low-resource and remote settings is constrained by access to specialized equipment and trained practitioners. We present SKINOPATHY AI, a smartphone-first web application that delivers five complementary, explainable screening modules entirely through commodity mobile hardware: (1) redness quantification via LAB a* color-space normalization; (2) blink-rate estimation using MediaPipe FaceMesh Eye Aspect Ratio (EAR) with adaptive thresholding; (3) pupil light reflex characterization through Pupil-to-Iris Ratio (PIR) time-series analysis; (4) scleral color indexing foricterus and anemia proxies via LAB/HSV statistics; and (5) iris-landmark-calibrated lesion encroachment measurement with millimeter-scale estimates and longitudinal trend tracking. The system is implemented as a React/FastAPI stack with OpenCV and MediaPipe, MongoDB-backed session persistence, and PDF report generation. All algorithms are fully deterministic, privacy-preserving, and designed for non-diagnostic consumer triage. We detail system architecture, algorithm design, evaluation methodology, clinical context, and ethical boundaries of the platform. SKINOPATHY AI demonstrates that multi-signal ophthalmic screening is feasible on unmodified smartphones without cloud-based AI inference, providing a foundation for future clinically validated mobile ophthalmoscopy tools.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 24, 2026

AnemiaVision: Non-Invasive Anemia Detection via Smartphone Imagery Using EfficientNet-B3 with TrivialAugmentWide, Mixup Augmentation, and Persistent Patient History Management

Anemia affects over one billion people globally and remains severely under-diagnosed in low-resource regions where laboratory blood tests are inaccessible. This paper presents AnemiaVision, an end-to-end web-based system for non-invasive anemia screening from smartphone photographs of the palpebral conjunctiva and fingernail beds. The proposed pipeline fine-tunes a pre-trained EfficientNet-B3 backbone with a redesigned three-layer classifier head incorporating BatchNorm, GELU activations, and high-rate Dropout (0.45/0.35). Training employs four orthogonal accuracy-boosting techniques: TrivialAugmentWide for policy-free image augmentation, RandomErasing for spatial regularisation, Mixup (alpha=0.2) for inter-class smoothing, and cosine-annealing scheduling with linear warmup. Early stopping is governed by peak validation accuracy rather than validation loss to prevent premature termination on high-variance epochs. The deployed Flask application integrates persistent patient-history management backed by PostgreSQL on Render, with an automated database-migration entrypoint ensuring zero data loss across redeploys. Ablation experiments demonstrate that accuracy-first early stopping contributes +1.6% and Mixup contributes +2.8% to final validation accuracy. Overall, the proposed system achieves a validation accuracy of 96.2% and AUC-ROC of 0.98, compared with 44.9% validation accuracy and AUC-ROC of 0.58 from the three-epoch CPU-only baseline. Sensitivity for the anemic class reaches 0.96, making the system suitable as a first-line screening tool for community health workers in rural settings. The system is publicly accessible and source code is openly available.
Sep 22, 2026

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83±\pm0.03 (Volk) and 0.87±\pm0.04 (Canon); Classification model: AUCs of 0.85±\pm0.01 (Volk) and 0.93±\pm0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.
Feb 25, 2026

Mobile-Ready Automated Triage of Diabetic Retinopathy Using Digital Fundus Images

Diabetic Retinopathy (DR) is a major cause of vision impairment worldwide. However, manual diagnosis is often time-consuming and prone to errors, leading to delays in screening. This paper presents a lightweight automated deep learning framework for efficient assessment of DR severity from digital fundus images. We use a MobileNetV3 architecture with a Consistent Rank Logits (CORAL) head to model the ordered progression of disease while maintaining computational efficiency for resource-constrained environments. The model is trained and validated on a combined dataset of APTOS 2019 and IDRiD images using a preprocessing pipeline including circular cropping and illumination normalization. Extensive experiments including 3-fold cross-validation and ablation studies demonstrate strong performance. The model achieves a Quadratic Weighted Kappa (QWK) score of 0.9019 and an accuracy of 80.03 percent. Additionally, we address real-world deployment challenges through model calibration to reduce overconfidence and optimization for mobile devices. The proposed system provides a scalable and practical tool for early-stage diabetic retinopathy screening.