eess.SYMar 7, 2026

A SISA-based Machine Unlearning Framework for Power Transformer Inter-Turn Short-Circuit Fault Localization

Authors: Nanhong Liu, Jingyi Yan, Mucun Sun, Jie Zhang

Organizations: The University of Texas at Dallas, Richardson, TX, USA · Idaho National Laboratory, Idaho Falls, ID, USA

Abstract

In practical data-driven applications on electrical equipment fault diagnosis, training data can be poisoned by sensor failures, which can severely degrade the performance of machine learning (ML) models. However, once the ML model has been trained, removing the influence of such harmful data is challenging, as full retraining is both computationally intensive and time-consuming. To address this challenge, this paper proposes a SISA (Sharded, Isolated, Sliced, and Aggregated)-based machine unlearning (MU) framework for power transformer inter-turn short-circuit fault (ITSCF) localization. The SISA method partitions the training data into shards and slices, ensuring that the influence of each data point is isolated within specific constituent models through independent training. When poisoned data are detected, only the affected shards are retrained, avoiding retraining the entire model from scratch. Experiments on simulated ITSCF conditions demonstrate that the proposed framework achieves almost identical diagnostic accuracy to full retraining, while reducing retraining time significantly.

Figures & tables

Explore similar work

Jun 24, 2026

DFMU: Data-Frugal Machine Unlearning

Machine unlearning is an emerging domain that ensures the safe removal of elements (includes concepts, attributes, entity and class) from the trained model along with least drop in model performance. The domain of machine unlearning brings its own indigenous challenges since the removal of pre-trained elements from model will always degrade the model performance on remaining elements. The existing methods basically rely on retraining for removal of elements from the pre-trained model, which is compute extensive. In this work, we propose a machine unlearning method which helps to reduce the computational requirement for faster retain-dataset accuracy convergence which also does not require extensive retraining of the pre-trained model. The proposed method, Data-Frugal Machine Unlearning (DFMU) requires only a single forward and backward pass for computing the importance score of various computational blocks of a model. The importance score computation is based on knowledge preserving pruning which helps to converge faster and requires far less data as compared to the existing methods. Experimentally, it achieves 40% more retain-accuracy with just 13% of data samples in comparison with SOTA method on various public datasets and also averages 88% faster processing time for forgetting a given class.
Jun 23, 2026

Lightweight Transformer Models for On-Device Fault Detection: A Benchmark Study on Resource-Constrained Deployment

On-device fault detection enables real-time diagnostics without cloud dependency, but deploying machine learning models on resource-constrained hardware demands careful tradeoffs between accuracy, latency, and model size. We present a benchmark comparing traditional ML methods (Random Forest, XGBoost, SVM, Logistic Regression) against lightweight transformer architectures (DistilBERT, TinyBERT-6L, TinyBERT-4L, MobileBERT) for binary fault detection across three public datasets: NASA C-MAPSS turbofan degradation, SECOM semiconductor manufacturing, and UCI AI4I 2020 predictive maintenance. We evaluate classification performance (F1-score, AUC), model size, and CPU inference latency, and further assess INT8 dynamic quantization and a two-stage adaptive inference pipeline. Our results reveal that on well-separated sensor data (C-MAPSS), lightweight transformers match traditional ML at 87.8% F1 but at 100x the model size and 9000x the latency. TinyBERT-4L emerges as the most deployment-friendly transformer at 55 MB and 18 ms CPU latency. INT8 quantization reduces size by 25% while preserving 86.9% F1. Our adaptive pipeline, routing 97.9% of predictions through a quantized triage model and only 2.1% to a larger expert, achieves 87.6% F1 at 19.5 ms average latency. On severely imbalanced datasets (SECOM, UCI-PM), both traditional and transformer methods struggle significantly, highlighting fundamental limitations of current approaches for extreme class imbalance in fault detection. All code is publicly available.
Sep 15, 2026

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.