DeepCORO-CLIP: A Multi-View Foundation Model for Comprehensive Coronary Angiography Video-Text Analysis and External Validation
Authors: Sarra Harrabi, Yichen Wu, Geoffrey H. Tison, Minhaj Ansari, Milos Vukadinovic, David Ouyang, Joshua P. Barrios, Jacques Delfrate, +1 more
Organizations: Division of Cardiology, Department of Medicine, Montreal Heart Institute, 5000 Belanger Street, QC, H1T 1C8 Canada · HeartWise.ai, 5000 Belanger Street, QC, H1T 1C8 Canada · McGill, Faculty of Engineering, Montreal, Quebec, Canada. · Division of Cardiology, Department of Medicine, University of California, San Francisco, Cardiology (San Francisco, CA, United States), 505 Parnassus Avenue, San Francisco, CA, 94143, United States of America · Cardiovascular Research Institute, University of California, San Francisco, CA, 94143, United States of America · Bakar Computational Health Sciences Institute, University of California, San Francisco, 94158, United States of America · Department of Cardiology, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA · Department of Bioengineering, University of California Los Angeles, Los Angeles, CA · Department of Medicine, Kaiser Permanente, San Francisco, USA · Department of Medicine, Université de Montréal, 2900 Edouard Montpetit Blvd, Montreal, Quebec H3T 1J4, Canada
Coronary angiography is the reference standard for evaluating coronary artery disease, yet visual interpretation remains variable between readers. Existing artificial intelligence methods typically analyze single frames or projections and focus mainly on stenosis, limiting comprehensive coronary assessment. We present DeepCORO-CLIP, a multi-view foundation model trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute and externally validated on 4,249 studies from the University of California, San Francisco. DeepCORO-CLIP integrates multiple projections with attention-based pooling for study-level assessment across diagnostic, prognostic, and disease progression tasks. For significant stenosis detection, the model achieved an AUROC of 0.888 internally and 0.89 on external validation. Mean absolute error against core laboratory quantitative coronary angiography was 13.6%, lower than clinical reports at 19.0%. The model also performed strongly for chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning enabled prediction of one-year major adverse cardiovascular events with AUROC 0.79 and estimation of left ventricular ejection fraction with mean absolute error 7.3%. Embeddings also captured disease progression across serial examinations. With a mean inference time of 4.2 seconds in hospital deployment, DeepCORO-CLIP provides a foundation for automated coronary angiography interpretation at the point of care. Code, sample data, model weights, and deployment infrastructure are publicly released.
Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-F1. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-F1 (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.
Jia-Jen Lee, Shih-Yen Hou, Kee Koon Ng +2
Artificial Intelligence and Robotics Innovation Center, China Medical University Hospital, Taichung, Taiwan · Division of Cardiovascular Medicine, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan · Department of Neurology, China Medical University Hospital, China Medical University, Taichung, Taiwan +2
Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols. In this work we demonstrate a new benchmark for the assessment of deep learning models which densely classify pixels of coronary angiograms to one of SYNTAX classes (or background). The evaluation covers 24 distinct architectures starting with classic convnets to recent state-space-based vision algorithms. We release CARDIAG - a multi-center, multi-label dataset which we carefully split to reliably compute metrics, accounting for diameter error, overlap, centerline quality and calibration. The data contains SYNTAX labels, binary, uncertainty and segmentation masks as well as intermediate frames together with the selected non-sensitive DICOM metadata. From the multitude of algorithms, we nominate ConvNeXt V2 encoder with DeepLab V3 Plus decoder as the best performing, achieving macro F1=0.456, which we then ensemble with Mamba U-Net and Feature Pyramid Network, for an increased F1=0.479. We demonstrate all the architectures to be well calibrated and determine the generalization of the top 5 methods, together with the data efficiency of these architectures. We highlight the importance of both high-resolution and low-resolution features in encoding. We also demonstrate the model correctness in the context of patient demographic, vessel sides and projection angle configurations. Overall the released benchmark allows for future studies to robustly and rigorously assess the proposals, not only for SYNTAX segmentation, but lesion detection and many more.
Dominik Bernard Lau, Hubert Malinowski, Jerzy Szyjut +5
Gdańsk University of Technology · NASK National Research Institute · Medical University of Gdańsk
Coronary artery disease, a leading cause of cardiovascular mortality worldwide, can be assessed non-invasively by coronary computed tomography angiography (CCTA). Although deep learning has advanced automated CCTA analysis, clinical translation remains constrained by the scarcity of expert-annotated data and by the spatial sparsity of coronary pathology, which occupies only a small fraction of each scan. Widely used label-free pretraining strategies, such as masked image modeling and contrastive learning, optimize for global anatomical reconstruction and tend to under-represent these tiny localized pathological features. Here we present CORA, an annotation-efficient model for comprehensive coronary artery disease assessment. Rather than reconstructing background anatomy, CORA learns from volumetric CCTA through a synthesis-driven self-supervised strategy: an anatomy-guided engine inserts diverse synthetic calcified and non-calcified lesions into unlabeled scans, reframing pretraining as an abnormality-detection task that biases representation learning toward clinically relevant disease features. We pretrained CORA on 10,138 unlabeled CCTA volumes and evaluated it across datasets from nine independent hospitals. Across plaque characterization, stenosis detection, and coronary artery segmentation, CORA consistently outperformed strong self-supervised pretraining baselines, with the largest gains on external multi-center data, indicating robust generalization under distributional shift. Coupling the imaging encoder with structured clinical variables further enabled near-term major adverse cardiac event (MACE) risk stratification. Our results show that pathology-centric, synthesis-driven pretraining is an effective and scalable strategy for annotation-efficient coronary artery disease assessment from CCTA.
Jinkui Hao, Gorkem Durak, Halil Ertugrul Aktas +4
Department of Radiology, Northwestern University, Chicago, IL, USA · Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA · Department of Cardiology, Northwestern University, Chicago, IL, USA +1