eess.IVMar 26, 2026

Toward Actionable Digital Twins for Radiation-Based Imaging and Therapy: Mathematical Formulation, Modular Workflow, and an OpenKBP-Based Dose-Surrogate Prototype

Authors: Hsin-Hsiung Huang, Bulent Soykan

Organizations: School of Data, Mathematical, and Statistical Sciences, University of Central Florida, Orlando, FL 32816 USA · Institute for Simulation and Training, University of Central Florida, Orlando, FL 32826 USA

Abstract

Digital twins for radiation-based imaging and therapy are most useful when they assimilate patient data, quantify predictive uncertainty, and support clinically constrained decisions. This paper presents a modular framework for actionable digital twins in radiation-based imaging and therapy and instantiates its reproducible open-data component using the \openkbpfull{} benchmark. The framework couples PatientData, Model, Solver, Calibration, and Decision modules and formalizes latent-state updating, uncertainty propagation, and chance-constrained action selection. As an initial implementation, we build a GPU-ready PyTorch/MONAI reimplementation of the \openkbp{} starter pipeline: an 11-channel, 19.2M-parameter 3D U-Net trained with a masked loss over the feasible region and equipped with Monte Carlo dropout for voxel-wise epistemic uncertainty. To emulate the update loop on a static benchmark, we introduce decoder-only proxy recalibration and illustrate uncertainty-aware virtual-therapy evaluation using DVH-based and biological utilities. A complete three-fraction loop including recalibration, Monte Carlo inference, and spatial optimization executes in 10.3s. On the 100-patient test set, the model achieved mean dose and DVH scores of 2.65 and 1.82Gy, respectively, with 0.58~s mean inference time per patient. The \openkbp{} case study thus serves as a reproducible test bed for dose prediction, uncertainty propagation, and proxy closed-loop adaptation, while future institutional studies will address longitudinal calibration with delivered-dose logs and repeat imaging.

Figures & tables

Explore similar work

Sep 21, 2026

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.
Jun 8, 2026

A practical probabilistic framework for deformable image registration uncertainty in radiotherapy dose propagation

Deformable image registration (DIR) is widely used in radiotherapy for dose propagation and accumulation, but uncertainty in the underlying deformation can substantially affect clinically relevant dose estimates. We present a practical probabilistic framework for propagating DIR uncertainty to voxel-wise dose statistics and dose-volume histograms (DVHs). The method models the mapped correspondence at each voxel as a random variable governed by a transparent local certainty map that can be defined by simple safety margins, structure-boundary mismatch, or structure-wise conservative uncertainty values. This yields interpretable quantities such as dose probabilities, expected dose, confidence bounds, and induced DVH envelopes. The framework is designed to remain lightweight and interpretable: it avoids complex biomechanical or ensemble-based uncertainty models and instead emphasizes simple parameterization, computational feasibility, and transparent dose metrics. We further introduce a structure-guided in/out strategy as an optional refinement that restricts mapping probabilities to anatomically plausible target regions. The approach is demonstrated on a prostate radiotherapy case study and used to compare different certainty-map strategies and probability kernels. The experiments show that the certainty-map design has a stronger effect on resulting dose and DVH uncertainty bounds than the specific kernel choice, while the additional benefit of the in/out strategy is case-dependent and modest in the present example. Overall, the proposed framework provides a transparent way to incorporate DIR uncertainty into radiotherapy dose assessment and to study how modelling choices affect propagated dose metrics.
Sep 30, 2026

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study

Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.