cs.CVApr 1, 2026

VLM-in-the-Loop: A Plug-In Quality Assurance Module for ECG Digitization Pipelines

Authors: Jiachen Li, Shihao Li, Soovadeep Bakshi, Wei Li, Dongmei Chen

Organizations: The University of Texas at Austin

Abstract

ECG digitization could unlock billions of archived clinical records, yet existing methods collapse on real-world images despite strong benchmark numbers. We introduce VLM-in-the-Loop, a plug-in quality assurance module that wraps any digitization backend with closed-loop VLM feedback via a standardized interface, requiring no modification to the underlying digitizer. The core mechanism is tool grounding: anchoring VLM assessment in quantitative evidence from domain-specific signal analysis tools. In a controlled ablation on 200 records with paired ground truth, tool grounding raises verdict consistency from 71% to 89% and doubles fidelity separation (ΔΔPCC 0.03 →\rightarrow 0.08), with the effect replicating across three VLMs (Claude Opus4, GPT-4o, Gemini2.5 Pro), confirming a pattern-level rather than model-specific gain. Deployed across four backends, the module improves every one: 29.4% of borderline leads improved on our pipeline; 41.2% of failed limb leads recovered on ECG-Digitiser; valid leads per image doubled on Open-ECG-Digitizer (2.5 →\rightarrow 5.8). On 428 real clinical HCM images, the integrated system reaches 98.0% Excellent quality. Both the plug-in architecture and tool-grounding mechanism are domain-parametric, suggesting broader applicability wherever quality criteria are objectively measurable.

Figures & tables

Appendix figures & tables19 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 6, 2026

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption. We developed ImputeECG, a mask-conditioned one-dimensional Transformer autoencoder that completes 12-lead, 10-s ECGs while retaining all observed samples. The model was trained on PTB-XL and evaluated on PTB-XL and CPSC2018 under simulated incomplete settings, with additional real-world validation in a 43,633-record Kailuan clinical cohort after ECG image digitization. Metrics were computed over originally missing regions, with analyses of morphology and downstream diagnostic utility. On PTB-XL, ImputeECG reduced missing-region MAE by 41.7-51.0% and MSE by 54.0-63.7% versus the strongest baseline, with lower errors in R-peak timing, RR interval, QRS duration, QT interval, and P-wave, QRS-complex, and T-wave reconstruction. On CPSC2018, ImputeECG reduced MAE by 49.7-51.9%, supporting external generalization. In downstream multi-label classification, ImputeECG restored performance to 92.28% AUROC and 33.88% AUPRC in the most incomplete PTB-XL setting, approaching complete-ECG performance. On CPSC2018, completed ECGs achieved 94.75-95.89% AUROC and 78.83-81.86% AUPRC across settings. In Kailuan, ECG completion improved zero-shot sex prediction AUROC from 82.6% to 85.8% and reduced age prediction MAE from 10.72 to 9.87 years after image-based ECG digitization. These findings support ECG completion as a practical strategy for converting incomplete ECG records into AI-ready 12-lead, 10-s digital signals and extending the usable scope of ECG archives for digital cardiac assessment.
Mar 15, 2026

ECG-Reasoning-Benchmark: A Benchmark for Evaluating Clinical Reasoning Capabilities in ECG Interpretation

While Multimodal Large Language Models (MLLMs) show promising performance in automated electrocardiogram interpretation, it remains unclear whether they genuinely perform actual step-by-step reasoning or just rely on superficial visual cues. To investigate this, we introduce ECG-Reasoning-Benchmark, a novel multi-turn evaluation framework comprising over 6,400 samples to systematically assess step-by-step reasoning across 17 core ECG diagnoses. Our comprehensive evaluation of state-of-the-art models reveals a critical failure in executing multi-step logical deduction. Although models possess the medical knowledge to retrieve clinical criteria for a diagnosis, they exhibit near-zero success rates (6% Completion) in maintaining a complete reasoning chain, primarily failing to ground the corresponding ECG findings to the actual visual evidence in the ECG signal. These results demonstrate that current MLLMs bypass actual visual interpretation, exposing a critical flaw in existing training paradigms and underscoring the necessity for robust, reasoning-centric medical AI. The code and data are available at https://github.com/Jwoo5/ecg-reasoning-benchmark.
Jan 5, 2026

ELF: A Family of Encoder-Free ECG-Language Models

ECG-Language Models (ELMs) extend recent advances in Multimodal Large Language Models (MLLMs) to automated ECG interpretation. However, most existing ELMs inherit Vision-Language Model (VLM) design choices and rely on pretrained ECG encoders, introducing substantial architectural and training complexity. Inspired by encoder-free VLMs, we introduce ELF, a family of three encoder-free ELMs that remain competitive with, and often outperform, prior state-of-the-art ELMs across two datasets despite substantially simpler architectures and training pipelines. All code and data are available at github.com/ELM-Research/ECG-Language-Models.