cs.CLApr 6, 2026

Benchmarking Multi-turn Medical Diagnosis: Hold, Lure, and Self-Correction

Authors: Jinrui Fang, Runhan Chen, Xu Yang, Jian Yu, Jiawei Xu, Ashwin Vinod, Wenqi Shi, Tianlong Chen, 

Organizations: The University of Texas at Austin · New York University · The University of Texas Southwestern Medical Center · University of North Carolina at Chapel Hill · 

Abstract

Large language models (LLMs) achieve high accuracy in medical diagnosis when all clinical information is provided in a single turn, yet how they behave under multi-turn evidence accumulation closer to real clinical reasoning remains unexplored. We introduce MINT (Medical Incremental N-Turn Benchmark), a high-fidelity, multi-turn medical diagnosis benchmark comprising 1,035 cases with clinically labeled evidence shards, controlled turn granularity, and information-preserving decomposition. Through systematic evaluation of 11 LLMs on MINT, we uncover three persistent behavioral patterns that significantly impact diagnostic decisions: (1) intent to answer, models rush to answer before sufficient evidence has been observed, with over 55% of answers committed within the first two turns; (2) self-correction, incorrect-to-correct answer revisions occur at up to 10.6 times the rate of correct-to-incorrect flips, revealing a latent capacity for self-correction that premature commitment forecloses; and (3) strong lures, clinically salient information such as laboratory results trigger premature answering even when models are explicitly instructed to wait. We translate these findings into clinically actionable guidance: deferring the diagnostic question to later turns reduces premature answering and improves accuracy at the first point of commitment by up to 62.6%, while reserving salient clinical evidence for later turns prevents a catastrophic accuracy drop of up to 23.3% caused by premature commitment. Our work provides both a controlled evaluation framework and concrete recommendations for improving the reliability of LLMs in multi-turn medical diagnosis.

Figures & tables

Appendix figures & tables7 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 8, 2026

MedAction: Towards Active Multi-turn Clinical Diagnostic LLMs

Most existing LLM diagnoses are evaluated on static, single-turn settings where complete patient information is provided upfront, an oversimplification of real clinical practice. We study active diagnosis: the real-life clinical process of starting from initial observation, ordering tests, interpreting results, and updating a differential diagnosis across multiple turns. Through systematic analysis, we identify three recurring failure modes in current LLMs: ungrounded test ordering, unreliable diagnostic update, and degraded multi-turn coherence. Together, these failures reveal a core deficit: existing medical training data teaches models to reason from complete information but not to act under evolving, partial evidence. To address this gap, we introduce MedAction, a tree-structured distillation pipeline that synthesizes diverse and high-quality multi-turn diagnostic trajectories via LLM-environment interaction. We propose two knowledge-graph-grounded metrics to filter trajectory quality: Disease Trajectory Consistency (DTC), which tracks whether the model's hypothesis converges toward the correct diagnosis, and Reasoning-Action Consistency (RAC), which verifies that belief updates are driven by gathered evidence. Using this pipeline, we construct MedAction-32K, a dataset of 32,681 trajectories from 2,896 PMC cases. Fine-tuning an 8B model on MedAction-32K achieves state-of-the-art performance among open-source models on both MedR-Bench and our curated MedAction-300-Hard benchmark, pushing the edge for open-source medical LLMs.
Aug 25, 2026

MTDiag: A Multi-Turn Diagnostic Dataset Towards Clinically Meaningful LLM Evaluation

Clinical diagnosis is fundamentally interactive and incremental, yet the dominant paradigm for evaluating Large Language Models (LLMs) in medicine remains static QA benchmarks or template-based dialogues. These benchmarks say little about whether a model can serve as a diagnostic agent in a dynamic clinical encounter, with LLMs showing significant accuracy and reliability degradation in multi-turn settings. To address this issue, we present MTDiag, a large multi-turn diagnostic dialogue dataset constructed from three heterogeneous sources: DDXPlus, MIMIC-IV, and published case reports (AJCR), covering common ED presentations as well as long-tail rare and atypical conditions. All cases are normalized into a canonical schema anchored in the most comprehensive and widely-adopted medical knowledge bases (UMLS concept identifiers, with ICD-10 diagnosis codes). We release the schema, a UserLM-8B-based utterance-generation pipeline, and the physician-validated dataset that converts structured clinical evidence into natural-language utterances. Importantly, we introduce and motivate clinical knowledge-grounded metrics for evaluating LLMs as diagnostic agents, beyond diagnostic accuracy, for the task of multi-turn differential diagnosis.
Mar 6, 2026

MedMT-Bench: Can LLMs Memorize and Understand Long Multi-Turn Conversations in Medical Scenarios?

Large Language Models (LLMs) have demonstrated impressive capabilities across various specialist domains and have been integrated into high-stakes areas such as medicine. However, as existing medical-related benchmarks rarely stress-test the long-context memory, interference robustness, and safety defense required in practice. To bridge this gap, we introduce MedMT-Bench, a challenging medical multi-turn instruction following benchmark that simulates the entire diagnosis and treatment process. We construct the benchmark via scene-by-scene data synthesis refined by manual expert editing, yielding 400 test cases that are highly consistent with real-world application scenarios. Each test case has an average of 22 rounds (maximum of 52 rounds), covering 5 types of difficult instruction following issues. For evaluation, we propose an LLM-as-judge protocol with instance-level rubrics and atomic test points, validated against expert annotations with a human-LLM agreement of 91.94%. We test 17 frontier models, all of which underperform on MedMT-Bench (overall accuracy below 60.00%), with the best model reaching 59.75%. MedMT-Bench can be an essential tool for driving future research towards safer and more reliable medical AI. The benchmark is available in https://openreview.net/attachment?id=aKyBCsPOHB&name=supplementary_material