eess.IVApr 8, 2026

4D Vessel Reconstruction for Benchtop Thrombectomy Analysis

Authors: Ethan Nguyen, Javier Carmona, Arisa Matsuzaki, Naoki Kaneko, Katsushi Arisaka

Organizations: UCLA Health · UCLA Physics and Astronomy · Chan Zuckerberg Biohub Network · Ronald Reagan UCLA Medical Center

Abstract

Introduction: Mechanical thrombectomy can cause vessel deformation and procedure-related injury. Benchtop models are widely used for device testing, but time-resolved, full-field 3D vessel-motion measurements remain limited. Methods: We developed a nine-camera, low-cost multi-view workflow for benchtop thrombectomy in silicone middle cerebral artery phantoms (2160p, 20 fps). Multi-view videos were calibrated, segmented, and reconstructed with 4D Gaussian Splatting. Reconstructed point clouds were converted to fixed-connectivity edge graphs for region-of-interest (ROI) displacement tracking and a relative surface-based stress proxy. Stress-proxy values were derived from edge stretch using a Neo-Hookean mapping and reported as comparative surface metrics. A synthetic Blender pipeline with known deformation provided geometric and temporal validation. Results: In synthetic bulk translation, the stress proxy remained near zero for most edges (median ≈\approx 0 MPa; 90th percentile 0.028 MPa), with sparse outliers. In synthetic pulling (1-5 mm), reconstruction showed close geometric and temporal agreement with ground truth, with symmetric Chamfer distance of 1.714-1.815 mm and precision of 0.964-0.972 at τ=1τ= 1 mm. In preliminary benchtop comparative trials (one trial per condition), cervical aspiration catheter placement showed higher max-median ROI displacement and stress-proxy values than internal carotid artery terminus placement. Conclusion: The proposed protocol provides standardized, time-resolved surface kinematics and comparative relative displacement and stress proxy measurements for thrombectomy benchtop studies. The framework supports condition-to-condition comparisons and methods validation, while remaining distinct from absolute wall-stress estimation. Implementation code and example data are available at https://ethanuser.github.io/vessel4D

Figures & tables

Explore similar work

CardsList
  1. A Position Statement on Endovascular Models and Effectiveness Metrics for Mechanical Thrombectomy Navigation, on behalf of the Stakeholder Taskforce for AI-assisted Robotic Thrombectomy (START)

    Mar 30, 2026Harry Robertshaw, Anna Barnes, Phil Blakelock +20Robotic Endovascular InterventionSurgical Robotics

  2. Vesselpose: Vessel Graph Reconstruction from Learned Voxel-wise Direction Vectors in 3D Vascular Images