cs.CVMay 6, 2026

3D Ultrasound-Derived Pseudo-CT Synthesis Using a Transformer-Augmented Residual Network for Real-Time Operator Guidance

Authors: Sapna SachanAmulya Kumar Mahto

Organizations: Indian Institute of Technology Guwahati, Assam, PIN 781039 India

Abstract

Computed tomography (CT) is indispensable for clinical diagnosis and image-guided interventions but exposes patients to ionizing radiation, motivating the development of safer imaging alternatives. Ultrasound (US) is non-ionizing and widely accessible; however, it is highly operator dependent and lacks quantitative tissue characterization, often leading to diagnostic uncertainty and unnecessary CT examinations. This work presents a 3D ultrasound-derived pseudo-CT (UD-pCT) framework that generates CT-like anatomical reference volumes inferred from US, without aiming to reproduce physically accurate Hounsfield Units. Paired 3D kidney US and CT volumes from the TRUSTED dataset are first spatially aligned using a landmark-based multimodal registration pipeline, creating high-quality paired inputs for supervised training of an adversarial framework. The proposed Bottleneck Transformer Residual U-Net3D (BT-ResUNet3D) model employs a 3D residual encoder-decoder generator augmented with a transformer bottleneck, enabling effective modeling of fine-grained local anatomical structures as well as long-range volumetric dependencies, while a 3D Conditional PatchGAN discriminator enforces local structural realism in the synthesized pseudo-CT volumes. Quantitative evaluation using PSNR and SSIM demonstrates that the proposed method outperforms established baselines in structural fidelity and perceptual image quality. The UD-pCT volumes provide real-time anatomical reference for operator guidance, potentially reducing acquisition variability and unnecessary CT use. A limitation of this study is the relatively small paired dataset, which may limit the generalizability of the proposed model.

Explore similar work

Sep 11, 2026cs.CV

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.
Weiying Chen, Yuchong Gao, Siyuan Li +3
Jun 18, 2026cs.CV

Pixel-Level Residual Diffusion Transformer: Scalable 3D CT Volume Generation

Generating high-resolution 3D CT volumes with fine details remains challenging due to substantial computational demands and optimization difficulties inherent to existing generative models. In this paper, we propose the Pixel-Level Residual Diffusion Transformer (PRDiT), a scalable generative framework that synthesizes high-quality 3D medical volumes directly at voxel-level. PRDiT introduces a two-stage training architecture comprising 1) a local denoiser in the form of an MLP-based blind estimator operating on overlapping 3D patches to separate low-frequency structures efficiently, and 2) a global residual diffusion transformer employing memory-efficient attention to model and refine high-frequency residuals across entire volumes. This coarse-to-fine modeling strategy simplifies optimization, enhances training stability, and effectively preserves subtle structures without the limitations of an autoencoder bottleneck. Extensive experiments conducted on the LIDC-IDRI and RAD-ChestCT datasets demonstrate that PRDiT consistently outperforms state-of-the-art models, such as HA-GAN, 3D LDM and WDM-3D, achieving significantly lower 3D FID, MMD and Wasserstein distance scores.
Zhenkai Zhang, Markus Hiller, Krista A. Ehinger +1
May 24, 2026cs.CV

DA-UCT: Self-Supervised Domain-Adaptive Ultrasound Computed Tomography for Rapid Musculoskeletal Sound Speed Reconstruction

Ultrasound computed tomography (UCT) via full waveform inversion (FWI) enables high-resolution quantitative imaging for tissue characterization and disease diagnosis. However, UCT suffers from large computational burden and severe convergence issues due to highly nonlinear optimization. Deep learning can accelerate UCT reconstruction, but supervised training requires large-scale labeled datasets difficult to obtain in vivo. To address these limitations, we propose SDA-UCT, a two-stage self-supervised domain-adaptive framework for rapid and accurate UCT imaging of musculoskeletal tissues. SDA-UCT employs an attention-enhanced network (AttUCT) pre-trained on simulation datasets and transfers to in-vivo data via physics-informed self-supervised learning, effectively bridging the simulation-to-real domain gap. A Low-Rank Adaptation (LoRA) mechanism is integrated to enable efficient adaptation across diverse clinical scenarios. Results showed that AttUCT achieved high-quality SOS reconstruction for simulated human forearm with a PSNR of 29.23 dB and SSIM of 0.928, outperforming conventional FWI and existing deep learning methods. Validated on in-vivo data, SDA-UCT successfully reconstructed SOS images revealing complex anatomical structures (skin, fat, muscle, tendon, bone and bone marrow) for human forearm, in high concordance with MRI references. The LoRA mechanism adjusting only 3% of parameters achieved comparable performance to full fine-tuning. The rapid reconstruction (5 ms per frame) enables real-time 3D visualization, achieving five-orders-of-magnitude improvement over traditional FWI. This work represents the first self-supervised domain-adaptive deep learning for rapid, high-resolution in-vivo UCT imaging, showing potential for musculoskeletal disease diagnosis.
Tianyu Liu, Heyu Ma, Aiduo Wang +6