cs.SDMay 14, 2026

Physics-Based iOCT Sonification for Real-time Interaction Awareness in Subretinal Injection

Authors: Luis D. Reyes VargasVeronica RuozziAndrea K. M. RossShervin DehghaniMichael SommerspergerKoorosh FaridpooyaMohammad Ali NasseriMerle Fairhurst+2 more

Abstract

Subretinal injection is a delicate vitreoretinal procedure requiring precise needle placement within the subretinal space while avoiding perforation of the retinal pigment epithelium (RPE), a layer directly beneath the target with extremely limited regenerative capacity. To enhance depth perception during cannula advancement, intraoperative optical coherence tomography (iOCT) offers high-resolution cross-sectional visualization of needle-tissue interaction; however, interpreting these images requires sustained visual attention alongside the en face microscope view, thereby increasing cognitive load during critical phases and placing additional demands on the surgeon's proprioceptive control. In this paper, we propose a structured, real-time sonification framework designed for extensible mapping of iOCT-derived anatomical features into perceptual auditory feedback. The method employs a physics-inspired acoustic model driven by segmented retinal layers from a stream of iOCT B-scans, with needle motion and injection-induced retinal layer displacements serving as excitation inputs to the sound model, enabling perception of tool position and retinal deformation. In a controlled user study (n=34), the proposed sonification achieved high retinal layer identification accuracy and robust detection of retinal deformation-related events, significantly outperforming a state-of-the-art baseline in overall event identification (83.4% vs. 60.6%, p < 0.001), with gains driven primarily by enhanced detection of injection-induced retinal deformation. Evaluation by experts (n=4) confirmed the clinical relevance and potential intraoperative applicability of the method. These results establish structured iOCT sonification as a viable complementary modality for real-time surgical guidance in subretinal injection.

Explore similar work

Sep 7, 2026cs.RO

Scene Graph-Driven Haptic Feedback for Safety Enhancement in Robotic Ophthalmic Surgery via Physically Simulated iOCT

Robotic ophthalmic surgery offers high precision but introduces a "sensory gap" by decoupling the surgeon from their instrument, resulting in a loss of tactile feedback. This paper presents a novel haptic feedback system for subretinal injection tasks leveraging Scene Graphs (SG). The system bridges the sensory gap by analyzing a physically simulated intraoperative Optical Coherence Tomography (iOCT) feed to construct a real-time surgical SG. The SG serves as a semantic abstraction layer for the surgical scene, which is then utilized by a deterministic, rule-based engine to generate state-dependent haptic feedback on a robotic input device. The system was evaluated in a user study (N=16) using an anthropomorphic head phantom and a custom-built surgical robot. Results demonstrate that the SG-driven haptic feedback improved surgical precision, reducing needle alignment error by 14% (p = 0.044) and improving System Usability Scale (SUS) scores by 8% (p = 0.015), while maintaining comparable task completion times. A needle trajectory analysis revealed the emergence of a safer "Align-then-Approach" strategy, in which our haptic negative reinforcement prompted users to fine-tune the tool's trajectory before approaching the retinal target. This work suggests that SGs can effectively serve as the direct computational foundation for real-time, safety-enhancing context-aware haptic feedback in robotic microsurgery.
Danial Arbabi, Korab Hoxha, Angelo Henriques +2
Aug 31, 2026cs.CV

Multimodal Shared Latent Representation of Narration, Microscope and iOCT Images for Phase Recognition in Vitreoretinal Surgery

Surgical phase recognition is key to context-aware computer-assisted feedback in vitreoretinal procedures, yet the scarcity of synchronized multimodal intraoperative data, particularly microscope views and intraoperative OCT, limits approaches that aim to replicate the multimodal integration surgeons perform naturally. Surgical narration, by contrast, is abundantly available online and offers rich semantic supervision. Prior work has mainly explored pairwise contrastive learning (e.g., intraoperative OCT-microscope or microscope-narration), leaving the joint modeling of all three modalities largely unexplored. We introduce a framework that uses microscope views as a shared anchor to bridge surgical narrations and intraoperative OCT (iOCT) without requiring a fully synchronized tri-modal dataset, leveraging real microscope-narration videos and a synthetic dataset of synchronized microscope video and tool-aligned iOCT pairs. Contrastive alignment transfers structural priors from the synthetic domain to real videos lacking iOCT, and a dual-head MS-TCN++ integrates the resulting embeddings for joint macro- and micro-phase prediction. Evaluated on real vitreoretinal surgeries, our framework improves macro-phase recognition over a zero-shot baseline (mean F1 0.38 to 0.53) and provides an exploratory route to estimating fine-grained instrument-tissue measurements that are not directly observable in real microscope video alone; these micro-phase estimates are validated quantitatively on synthetic data and shown only qualitatively on real surgery. To our knowledge, this is the first work to unify microscope view, iOCT B-scans, and surgical narrations in a shared latent space for surgical phase recognition.
Onur Izmitlioglu, Shervin Dehghani, Tarek Ghannoum +2
May 4, 2026cs.CV

SAIL: Structure-Aware Interpretable Learning for Anatomy-Aligned Post-hoc Explanations in OCT

Optical coherence tomography (OCT), a commonly used retinal imaging modality, plays a central role in retinal disease diagnosis by providing high-resolution visualization of retinal layers. While deep learning (DL) has achieved expert-level accuracy in OCT-based retinal disease detection, its "black box" nature poses challenges for clinical adoption, where explainability is essential for clinical trust and regulatory approval. Existing post-hoc explainable AI (XAI) methods often struggle to delineate fine-grained lesion structures, respect anatomical boundaries, or suppress noise, limiting the trustworthiness of their explanations. To bridge these gaps, we propose a Structure-Aware Interpretable Learning (SAIL) framework that integrates retinal anatomical priors at the representation level and couples them with semantic features via a fusion design. Without modifying standard post-hoc explainability methods, this representation yields sharper and more anatomically aligned attribution maps. Comprehensive experiments on diverse OCT datasets demonstrate that our structure-aware method consistently enhances interpretability, producing clinically meaningful and anatomy-aware explanations. Ablation studies further show that strong interpretability requires both structural priors and semantic features, and that properly fusing the two is critical to achieve the best explanation quality. Together, these results highlight structure-aware representations as a key step toward reliable explainability in OCT.
Tienyu Chang, Tianhao Li, Ruogu Fang +2