cs.LGJul 15, 2026

Temperature Scaling Is Not Enough: Calibration Gaps Under Human Label Distributions

Authors: Wisdom Dogah

Organizations: Faculty of Computing and Mathematical Sciences, University of Mines and Technology (UMaT), Tarkwa, Ghana. · BlackMatrix AI Research, Accra, Ghana.

Abstract

Temperature scaling is the dominant post-hoc calibration method in modern deep learning. Its theoretical justification rests on an assumption that is rarely stated explicitly: that ground-truth labels are one-hot and deterministic. In practice, labels are frequently soft, crowd-sourced, or genuinely distributional, reflecting real disagreement among human annotators rather than annotation noise. We study whether temperature scaling retains its calibration properties when this assumption is violated, and whether any resulting degradation depends on model scale. Using CIFAR-10H and ChaosNLI, two publicly available datasets with human-annotated soft label distributions, we evaluate three model scales per modality under both hard one-hot and soft distributional label targets. Across all nine configurations we find a positive soft-label calibration gap: temperature scaling calibrated on hard labels consistently underperforms an oracle calibrated directly on soft labels, with Brier Score gaps ranging from 0.002 to 0.134. The gap grows monotonically with model scale in the vision domain and on the SNLI-derived split of ChaosNLI, and is substantially larger in the language domain (mean gap 0.079) than in vision (mean gap 0.003). A scale-ordering reversal on the MNLI-derived split remains after matched-domain training; we treat it as inconclusive for the scale hypothesis and attribute it primarily to near-chance accuracy on that split. As a second post-hoc baseline, multiclass isotonic regression yields the same qualitative conclusion: positive soft-label gaps in all nine configurations, and larger gaps in language than in vision. These findings suggest that calibration protocols built on majority-vote labels systematically misstate model reliability wherever label ambiguity is structural, with direct consequences for deployment in safety-critical settings.

Explore similar work

May 18, 2026cs.LG

An Assessment of Human vs. Model Uncertainty in Soft-Label Learning and Calibration

Central to human-aligned AI is understanding the benefits of human-elicited labels over synthetic alternatives. While human soft-labels improve calibration by capturing uncertainty, prior studies conflate these benefits with the implicit correction of mislabeled data (mode shifts), obscuring true effects of soft-labels. We present a controlled audit of soft-label learning across MNIST and a synthetic variant, re-annotating subsets to extract human uncertainty. By decoupling soft-label supervision from underlying label mode shifts, we show that while human soft-labels do provide accuracy gains, their larger value lies in acting as a regularizer that improves model calibration on difficult samples and promotes stable convergence across training runs. Dataset cartography reveals models trained on human soft-labels mirror human uncertainty, whereas those trained on synthetic labels fail to align with humans. Broadly, this work provides a diagnostic testbed for human-AI uncertainty alignment.
Maja Pavlovic, Silviu Paun, Massimo Poesio
Jul 20, 2026cs.LG

The Calibration Channel Determines the Bayes-Error Proxy: An Exact Law for Temperature-Induced Distortion

The soft-label Bayes-error estimator beta(z) = E[min(z, 1-z)] of Ishida et al. estimates the irreducible error of a binary task directly from probability-valued labels. Recent work by Ushio et al. showed that this estimator is fragile when the probabilities are not the true posterior: even perfectly calibrated soft labels can yield a substantially inaccurate estimate, and they propose isotonic calibration as a consistent remedy. We complement that line of work by characterizing exactly how the most widely used post-hoc calibration map -- temperature scaling -- distorts the proxy. We prove an exact, model-free identity reducing the temperature-scaled proxy to the classifier's margin distribution, from which we obtain (i) strict monotonicity in the temperature and (ii) a continuous bijection from the temperature axis onto the open interval (0, 1/2), so that a fixed classifier -- with fixed decisions and fixed 0-1 error -- can be made to report any proxy value whatsoever. Under a Gaussian model of the logits we further derive a two-parameter closed form for the entire proxy-versus-temperature curve. Across CIFAR-10, Fashion-MNIST, and SVHN (eight binary tasks), the proxy varies by 56x to 980x at constant test error, the closed form reproduces the empirical curve to within 0.018, and the calibration temperature that minimizes the expected calibration error does not coincide with any stable proxy value. Our results give a precise, predictive account of the distortion whose existence motivates calibration-based remedies, and they reinforce the practical recommendation that a proxy value is meaningful only together with the mechanism that produced its probabilities.
Shreyas Pradeepkumar Khandale
Jun 19, 2026cs.CV

Quantile Adaptive Temperature Scaling for Confidence Calibration

Deep neural networks often produce poorly calibrated confidence estimates, overstating their certainty even when predictions are incorrect. Temperature Scaling remains the most widely used posthoc calibration method due to its simplicity and effectiveness, yet its global, uniform rescaling of logits fails to correct the highly heterogeneous structure of miscalibration observed across the confidence spectrum. In particular, the largest correctness confidence discrepancies arise in different quantile regions depending on the setting, low confidence predictions, where uncertainty matters most, tend to exhibit the largest correctness confidence discrepancies, which standard TS leaves largely unaddressed. We introduce Quantile Adaptive Temperature Scaling (QaTS), a simple and efficient post hoc calibration method that adapts the temperature as a function of a predictions empirical confidence quantile. By mapping confidences into the quantile space, QaTS normalizes the calibration problem, makes the structure of miscalibration explicit and enables a monotone temperature function that adapts across quantiles while leaving well calibrated high confidence predictions largely unchanged. preserving high confidence behavior. This quantile aware formulation aligns naturally with a reparameterized Expected Calibration Error (ECE) objective and yields a sample wise temperature that is robust across a variety of challenging scenarios, such as class imbalance and distributional shifts. Across a broad range of datasets, architectures, evaluation scenarios and diverse tasks, QaTS consistently, and substantially, outperforms state of the art post hoc calibration methods, delivering more reliable and trustworthy confidence estimates without modifying model predictions.
Omprakash Chakraborty, Leo Fillioux, Ismail Ben Ayed +1