Organizations: Graduate Institute of Biomedical Informatics, College of Medical Science and Technology, Taipei Medical University, Taipei, 235, Taiwan. · International Center for Health Information Technology, College of Medical Science and Technology, Taipei Medical University, Taipei, 235, Taiwan. · Biomedical Sensors & Systems Lab, University of Memphis, Memphis, TN 38152, USA · Centre of Research Impact and Outcome, Chitkara University, Rajpura- 140417, Punjab, India · UCL Hawkes Institute, University College London, London, UK · Queen Square Institute of Neurology, University College London, London,UK · School of Computer Science, UPES, Dehradun, 24800, Uttarakhand, India · University of Eastern Finland, FI-70210 Kuopio, Finland · CNRS, University Bordeaux, Bordeaux INP, LABRI, UMR5800, Talence F-33405, France · School of Gerontology and Long-term Care, College of Nursing, Taipei Medical University, Taipei, Taiwan, 110.

Abstract

Multimodal neuroimaging combining structural MRI and positron emission tomography (PET) captures complementary structure-function relationships across the Alzheimer's disease (AD) continuum, yet existing artificial intelligence systems produce a single diagnostic label without quantifying which imaging modality drove that decision for a specific patient. We introduce the Modality Contribution Network (MCNet) and the Modality Contribution Score (MCS), the first per-patient attribution framework quantifying the shift in modality dominance from structural atrophy to amyloid and metabolic dysfunction across the cognitively normal to MCI to AD continuum. MCS is normalised to unity per subject via modality ablation (MCS_MRI_i + MCS_PET_i = 1.0 for every subject i), providing an interpretable, clinically actionable score that fluid biomarkers cannot supply. Applied to 327 ADNI-3 participants balanced across cognitively normal, mild cognitive impairment, and AD groups, MCNet achieved competitive three-class staging performance (AUC=0.881). The MCS revealed a statistically significant monotonic gradient (Kruskal-Wallis p<0.0001), with increasing PET dominance from cognitively normal (MCS_PET 0.412+/-0.229) through MCI (0.489+/-0.289) to AD (0.671+/-0.426), validated against amyloid SUVR (r=0.172, p=0.006) and FDG metabolic biomarkers (r=-0.287, p=0.0005) from separate imaging pipelines. External replication in 1,073 independent OASIS-3 subjects confirmed cross-cohort generalisability (H=166.99, p<0.0001, eta^2=0.156). A mechanistic comparison with SHAP demonstrated that ablation-based MCS captures clinically meaningful modality dependence that deviation-based methods cannot. These findings position MCNet as a foundation for personalised imaging decisions, clinical trial stratification, and trustworthy AI in dementia care.

Explore similar work

Sep 28, 2026

Evidence Before Accuracy: A MRI-PET Fusion Network for Alzheimer Disease Classification with Causal Regional Validation

Deep learning models for Alzheimer disease (AD) classification routinely report near-perfect discrimination, yet few are shown to rest on AD-relevant neurobiology rather than on dataset artifacts, subject-level leakage, or non-brain image content. We present a fusion network combining T1 MRI and FDG PET across axial, coronal, and sagittal planes, trained on ADNI consists of 554 paired subjects. The fusion model reaches AUC 0.962, accuracy 0.909, and F1 0.891, competitive with recent 3D CNN and multimodal transformer systems at substantially lower cost. We first quantify how much modality, plane and slice geometry matter. A validation-only search over slice centres and neighbour spacings moves AUC by 0.180 for MRI and 0.078 for PET, selecting narrow spacing for MRI and wide spacing for PET, with the chosen coronal centres falling on the hippocampal body and on the posterior cingulate respectively. The contribution, however, is the evidence layer built around that number. Shortcut controls collapse the model to AUC 0.622 (silhouette), 0.608 (exterior), and 0.500 (blank), and a label-permutation null yields 0.456. Forward region-of-interest (ROI) ablation shows that masking medial temporal cortex in MRI and the posterior default-mode network (DMN) in PET produces the largest shift in the AD logit, while area-matched controls remain indistinguishable from that null. Reverse ROI ablation shows that the medial temporal lobe alone retains 89.2% of above-chance discrimination in MRI and the posterior DMN alone retains 79.0% in PET. A quantitative comparison of attribution methods shows occlusion sensitivity reaching 3.5-5.0* enrichment inside a priori AD regions against 0.10-0.43* in controls. Ablation and attribution independently establish a biologically correct double dissociation: hippocampal evidence is carried by MRI, posterior cingulate evidence by PET.
Jun 18, 2026

Alzheimer's Disease Diagnosis using a Multimodal Approach with 3D MRI and PET

Alzheimer's disease (AD) is an irreversible neurodegenerative disorder and a leading cause of death worldwide. Early diagnosis plays an important part especially at the Mild Cognitive Impairment stage, where timely intervention can help slow its progression before it advances to AD. Neuroimaging data, like Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) scans, can help detect brain changes early by providing structural and functional brain changes related to the disease. Yet, many multimodal models still fuse MRI and PET with static concatenation and apply identical computation to all subjects, which limits robustness to patient/site heterogeneity and can waste computation. To address these limitations, we present the first study of combining 3D convolutional feature extractors with three fusion strategies - concatenation, Gated Multimodal Unit (GMU), and gated self-attention - and a sparsely gated Mixture-of-Experts (MoE) classifier that performs input-adaptive routing, activating only the most informative experts per case. Finally, we utilize Grad-CAM to visualize disease-related regions, ensuring model interpretability. Experiments are performed across three binary classification tasks (NC vs. MCI, MCI vs. AD, and NC vs. AD). Results show that GMU achieves accuracies of 80.46 % (NC vs. MCI) and 95.47 % (NC vs. AD), while gated self-attention attains 82.08 % on MCI vs. AD. Ablations show that removing the MoE consistently degrades accuracy across all tasks. These findings underscore the value of input-adaptive, multimodal modeling for AD diagnosis by leveraging the complementary nature of MRI and PET.
Sep 14, 2026

Anatomical Grounding and Leakage-Aware Multimodal Contrastive Learning for Alzheimer's Disease Classification from Structural MRI

Deep networks trained on structural MRI for Alzheimer's disease (AD) staging often reach reasonable accuracy while attending to anatomically irrelevant regions, and multimodal models that add clinical tables frequently rely on variables that were used to assign the diagnostic label in the first place. We study both issues with a deliberately lightweight slice-based encoder (ResNet18 with a one-layer Transformer over slices) on 1,075 baseline T1-weighted scans from ADNI-1. First, we use FastSurfer segmentations as an anatomical reference: YOLOv8 models trained on segmentation-derived labels localize Alzheimer-relevant structures with mAP_50 above 0.96, and a Grad-CAM comparison shows that the image-only classifier frequently attends to the skull, orbits and background. Second, we adapt a CLIP-style image - tabular contrastive framework and organize ADNIMERGE variables along a label-leakage spectrum. Fusion with cognitive scores yields 87.3% three-way accuracy, which we treat as a leakage-driven upper bound rather than an imaging result; fusion with regional volumes yields 73.0%. We observe that the choice of contrastive target changes what the image encoder learns: on MCI vs. CN, the image-only head reaches 52.4% when the encoder is aligned to cognitive scores and 73.8% when aligned to volumes, although no tabular input is used at inference. Third, restricting the input to a per-subject crop of the medial temporal lobe raises image-only three-way accuracy from 58.7% to 65.1%. All results come from single runs on a small balanced test set, and we report confidence intervals and the protocol differences that prevent direct comparison with published numbers.