cs.CVAug 28, 2026

A Controlled Audit of Architectural Complexity in Uncertainty-Aware Multi-Organ Ultrasound Classification

Authors: Yang Song, Pengbo Sun, Shichang Feng, Ye Zhu, Xin Xu, Ziran Wang

Organizations: Department of Mechanical Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong · School of Electronic and Information Engineering, Beihang University, Beijing, 100191, China · Hangzhou International Innovation Institute, Beihang University, Hangzhou, 311115, China · College of Artificial Intelligence, Nanjing University of Aeronautics and Astronautics, Nanjing, China · Independent Researcher, Jinan, Shandong, China · Key Laboratory of High Efficiency and Clean Mechanical Manufacture, Ministry of Education, School of Mechanical Engineering, Shandong University, 250000, Jinan, China

Abstract

Multi-organ ultrasound classifiers increasingly combine attention, mixture-of-experts routing, uncertainty gating, and evidential deep learning (EDL) objectives to address heterogeneous anatomy and acquisition. Yet a plausible design rationale does not by itself establish that an added component improves the trained system. We contribute a controlled complexity-audit framework, applied to the deployment decision between the maximal evidential candidate Full-EDL and simpler alternatives. Six candidates were evaluated on the primary dataset and three in an internal replication, using ten matched seeds, frozen image-level partitions, capacity- and optimisation-aware comparisons, symmetric temperature scaling, paired decision rules, and a separate out-of-distribution (OOD) veto. Retaining Full-EDL did not establish a reliable macro-F1 gain on either dataset, while the simplified alternatives remained inconclusive under the non-inferiority margin. Simple cross-entropy with temperature scaling (Simple-CE+TS) met the calibrated negative log-likelihood criterion on both datasets and showed favourable selective-risk ordering. The raw calibration advantage of evidential training disappeared after temperature scaling and did not recur on the second dataset. The gate had negligible observable influence at the audited checkpoints, and deleting the Full-only chain revealed no stable task or calibrated-loss benefit. Simple-CE nevertheless triggered the OOD veto against the fetal probe but not the lung probe, precluding an unconditional OOD-safety claim. We therefore selected Simple-CE+TS for the evaluated in-distribution objective while retaining Full-EDL as the maximal reference. Components should earn retention through functional and retraining-based evidence, and calibration and distribution-shift reliability should be evaluated separately.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. C2^2LUE: Clinically Aligned Patient-Level Ultrasound Diagnosis via Evidence-Aware Multi-Instance Learning

    Oct 9, 2026Qin-Yi Zhang, Linying Cao, De-Xing Huang +7Multiple Instance LearningUltrasound Imaging

  2. Uncertainty-driven training for three-dimensional calibrated lung nodule classification

    Sep 17, 2026Giuseppe Tripodi, Alessandro De Rosis, Saleh RezaeiraveshMedical Image ClassificationUncertainty Calibration

  3. Echo-α: Large Agentic Multimodal Reasoning Model for Ultrasound Interpretation

    Apr 30, 2026Jing Zhang, Wentao Jiang, Tao Huang +8Medical Image AnalysisMultimodal Reasoning