Translating electroencephalography (EEG) into functional magnetic resonance imaging (fMRI) is important for medical neuroimaging, clinical brain-state monitoring, and multimodal neural decoding, because it aims to infer spatially organized hemodynamic activity from fast and accessible electrophysiological recordings. Existing EEG-to-fMRI studies mainly pursue stronger decoders, but the problem is also constrained by a representation-interface mismatch: fMRI responses are delayed, temporally integrated, and spatially distributed, whereas generic EEG encodings often entangle temporal lag, channel identity, and frequency-band structure. We propose Multi-band EEG Latent-state Tokenization (MEL), a coordinate-preserving EEG representation framework that anchors each target fMRI response to its preceding EEG history and organizes it into lag-channel-frequency neural-state tokens. By explicitly capturing hemodynamic latency and spectral-spatial dynamics, MEL aligns fMRI-pertinent EEG representations with capacity-controlled readouts without depending entirely on model scaling. Experiments on VU EEG-fMRI benchmarks and external Oddball data show that MEL improves prediction over strong NeuroBOLT baselines. Ablations and controls further indicate that the gains come from structured EEG representation rather than leakage, shortcut statistics, or decoder capacity.
Figures & tables
Figure 1: Representation-centric view of ROI-level EEG-to-fMRI prediction. Many EEG encodings model lag, channel, and frequency information implicitly, whereas MEL exposes these axes as explicit target-relative coordinates before decoding.
Figure 2: Overall framework of MEL. The method anchors each fMRI target to its preceding EEG history, constructs lag-channel-frequency tokens through train-only calibrated bandpower extraction, and decodes the resulting representation into ROI responses using capacity-controlled readouts.
Setting
Model
Primary Sensory
High-level Cognitive
Subcortical
Global Signal
Avg. R ↑
Cuneus
Heschl’s Gyrus
Middle Frontal
Precuneus Anterior
Putamen
Thalamus
Intra-scan
BIOT ( Yang et al. 2023 )
0.531 ± 0.223
0.518 ± 0.207
0.490 ± 0.162
0.459 ± 0.110
0.410 ± 0.205
0.411 ± 0.231
0.493 ± 0.133
0.473
LaBraM ( Jiang et al. 2024 )
0.540 ± 0.176
0.519 ± 0.197
0.493 ± 0.153
0.490 ± 0.176
0.411 ± 0.179
0.449 ± 0.177
0.487 ± 0.167
0.484
BEIRA ( Kovalev et al. 2022 )
0.357 ± 0.241
0.396 ± 0.240
0.294 ± 0.228
0.320 ± 0.220
0.234 ± 0.194
0.328 ± 0.197
0.456 ± 0.240
0.341
SIREN ( Li et al. 2024a )
0.460 ± 0.228
0.515 ± 0.207
0.376 ± 0.169
0.457 ± 0.204
0.324 ± 0.183
0.398 ± 0.194
0.583 ± 0.170
0.445
NeuroBOLT ( Li et al. 2024b )
0.588 ± 0.166
0.566 ± 0.183
0.502 ± 0.168
0.559 ± 0.141
0.437 ± 0.184
0.480 ± 0.213
0.587 ± 0.162
0.531
Table 1: EEG-to-fMRI prediction under intra-scan and inter-subject evaluation. Entries report mean ± standard deviation, and Avg. R is averaged over the seven targets. Red and blue denote the best and second-best results within each setting. All neural and traditional baselines are reproduced under the same preprocessing, split, train-only normalization, and validation-based model-selection pipeline rather than taken from incompatible reporting protocols. BP denotes bandpower, and inter-subject results follow strict leave-one-subject-out evaluation over 22 subjects and 29 scans.
Model
Primary Sensory
High-level Cognitive
Subcortical
–
Avg. R ↑
Cuneus
Heschl’s Gyrus
Middle Frontal
Precuneus Anterior
Putamen
Thalamus
Global Signal
MSE ↓
R ↑
MSE ↓
R ↑
MSE ↓
R ↑
MSE ↓
R ↑
MSE ↓
R ↑
MSE ↓
R ↑
MSE ↓
R ↑
T2
0.424
0.164
0.353
0.165
0.324
0.395
0.353
0.358
0.446
0.242
0.351
0.333
0.356
0.383
0.292
T1
0.325
0.221
0.299
0.182
0.314
0.447
0.302
0.390
0.310
0.252
0.323
0.373
0.281
0.410
0.325
M+B3
0.315
0.383
0.291
0.305
0.314
0.451
0.322
0.466
0.341
0.343
0.345
0.410
0.302
0.489
0.407
M+B5
0.259
0.434
0.263
0.333
0.265
0.516
0.248
0.502
0.320
0.373
0.277
0.455
0.247
0.551
0.452
Table 2: Ablation of MEL components. M denotes the lag-channel-band coordinate system. B3 and B5 use three and five frequency bands, respectively. T1 and T2 denote HRF-weighted and time-mean aggregation. All variants share the same Ridge readout.
Figure 3: External transfer at different temporal depths. Oddball performance improves as a longer ordered EEG history is retained, whereas NODDI remains near zero under the available alignment cache.
Control
Broken structure
Avg. R↑
ΔR
Normal MEL
None
0.4521
–
All-split z -score
Normalization split
0.4521
- 0.0000
Channel permutation
Channel identity
0.3945
-0.0576
Band reversal
Spectral semantics
0.2355
-0.2166
Random lag
Sample alignment
0.1977
-0.2544
Lag reversal
Hemodynamic order
0.1022
-0.3499
Table 3: Representation-validity controls. Each experiment keeps the Ridge readout fixed while disrupting one component of MEL.
Figure 4: Temporal-design ablation. Bars report test Avg. R , while black curves report validation Avg. R .
Figure 5: MEL coordinate-sensitivity summary across frequency bands, temporal lags, and ROI groups. Values combine normalized marginal band-ablation, lag-ablation, and ROI-gain diagnostics within the displayed map.
Figure 6: Examples of fMRI ROI reconstruction on unseen scans. Dashed gray curves denote ground-truth responses, and colored curves denote MEL predictions.
Neuroscientists have recently turned to intracranial brain recording methods, like electrocorticography (ECoG), for human experiments because of the fine spatial and temporal resolution that they afford. Models trained on this data, however, are fundamentally restricted by the patient populations that can receive the implants necessary for recording. We propose using non-invasive fMRI to bridge the gap in training data. Using spoken language representations fine-tuned on fMRI, we build encoding models of ECoG. These representations showed improved prediction performance in ECoG, even though the temporal resolution of fMRI is two orders of magnitude worse. Prediction improved in frequency bands well beyond what is directly measured in fMRI. Next, to test the procedure's generalization ability, we fine-tuned models on fMRI responses that were temporally downsampled by a factor of 2. Despite the loss in resolution, these models were able to predict fMRI and ECoG responses at levels comparable to the original fMRI-tuned models. Finally, we showed that ECoG performance steadily scales with the amount of fMRI-tuning data. Our results show that "slow" data like fMRI can be a valuable resource for building better models of "fast" brain data like ECoG. In the future, integrating across multiple recording methods may further improve performance in other applications, like decoding.
Aditya R. Vaidya, Richard J. Antonello, Alexander G. Huth
Department of Computer Science The University of Texas at Austin, USA · Zuckerman Mind Brain Behavior Institute Columbia University, USA · Departments of Neuroscience and Statistics University of California, Berkeley, USA
Self-supervised pretrained foundation models (FM) have shown early promise for non-invasive electroencephalogram (EEG) decoding applications. Many recent large-scale models converged on the approach of tokenizing raw EEG followed by masked reconstruction pretraining. However, this recipe has been shown to be suboptimal for data, like EEG, with high noise amplitude and information confined to limited dimensions such as narrow frequency bands. Building on this insight, we develop a novel contrastive-pretrained EEG model with multiscale temporal convolution input layers and Transformer encoder blocks (CoCoT). CoCoT matches or beats state-of-the-art reconstruction-pretrained EEG models on extensive benchmark decoding tasks with heterogeneous electrode configurations. Furthermore, CoCoT trained from scratch outperforms previous single-task decoding models and even rivals pretrained models, showcasing the architecture's flexibility and data efficiency. Through systematic ablations, including model architecture and pretraining objective, we demonstrate the viability of contrastive learning for building EEG FMs while suggesting key architectural design considerations, prompting further investigations in alternative large-scale pretraining strategies.
Gabriel Mahuas, Victoria Shevchenko, Ugo Tanielian +2
Sigma Nova Paris, France · Goethe University Frankfurt Frankfurt, Germany
Recent advances in EEG foundation models have demonstrated the potential of large-scale pretraining to enable generalizable neural decoding across subjects, recording environments, and datasets. However, dominant pretraining paradigms face key challenges: masked autoencoding tends to prioritize low-level signal reconstruction over task-relevant semantics, while autoregressive modeling creates a mismatch between continuous neural dynamics and discrete token spaces. To address these challenges, new strategies are needed to effectively align continuous EEG representations with natural-language semantics and enable their integration with large language models. Accordingly, we propose Brain Latent Predictive Model (BLPM), an EEG-language foundation model that reformulates heterogeneous EEG decoding tasks as a continuous semantic embedding prediction problem. BLPM introduces a Continuous EEG Latent Predictive (CELP) encoder that learns transferable representations through latent target prediction. Building on these representations, a Multi-Query Semantic Decomposition (MQSD) module extracts task-relevant information and aligns continuous EEG representations with textual semantics within a shared latent space according to their semantic relationships. Experiments across multiple benchmarks demonstrate consistent generalization performance across diverse tasks, establishing continuous latent semantic prediction as an effective paradigm for EEG-language foundation models.
Myeong-Ju Cho, Hye-Bin Shin, Seo-Hyun Lee +1
Department of Brain and Cognitive Engineering, Korea University, Seoul, Republic of Korea · Department of Artificial Intelligence, Korea University, Seoul, Republic of Korea