Abstract
Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging the point cloud and RGB images of a structured light 3D camera, our proposed method performs an image-based segmentation for delineating the BPCs from the RGB images, accompanied by novel geometry-based thickness measurement algorithms performed on the point cloud scans. These algorithms combine the segmentation mask with the robot's forward kinematics data and a 3D point cloud scan to precisely measure the aforementioned metrics for complex-shaped BPCs. The proposed method was evaluated in simulation and experimental studies. In simulation studies, the algorithms were used to measure the thickness of some virtually created BPCs with known thickness. The comparison between the measured and true thicknesses demonstrates the high accuracy of the proposed method, achieving mean absolute errors between 0.025 mm and 0.057 mm in simulation at a spatial resolution of 0.1 mm x 0.1 mm per pixel. Furthermore, we successfully deployed the algorithms on our robotic bioprinting setup utilizing a structure light 3D camera, where complex patterns were printed and the developed methods utilized to accurately measure the thickness of printed BPCs.
Explore similar work
Sep 14, 2026cs.RO
Robotic bioprinting and Direct Ink Writing (DIW) are being explored towards the treatment of Volumetric Muscle Loss (VML). While previous studies have shown the importance of proper parameter selection on the print outcome, existing approaches often rely on time- and material-intensive design of experiments methods, or require large, well-curated datasets for training machine learning models. In this paper, we propose a physics-based closed-loop robotic bioprinting system capable of near real-time parameter adaptation. The system integrates a 3D point cloud camera and fully autonomous vision-based algorithms to provide quantitative evaluation of printed constructs. This evaluation is fed into a controller that adjusts printing parameters to achieve a desired bead thickness. To assess the framework's performance, four experimental configurations were tested, each repeated three times. In these tests, printing began from an arbitrary initial parameter value, and the controller was tasked with adjusting the parameters to reach the desired thickness. The system converged in all trials, achieving a tracking error below 0.5 mm within an average of 5.2 seconds from the start of printing. The low standard deviation of the converged pressure over different tests (0.04 bar on average) demonstrates robustness and repeatability. Additional experiments were conducted with the controller turned off, enabling direct comparison with open-loop DIW bioprinting, further confirming the effectiveness of the proposed closed-loop framework in achieving the desired bead geometry.
Omid Rezayof, Jerin T. Andrews, Ehsan Zobeidi +5
Jun 13, 2026cs.RO
Spin coating is widely used for fabrication of thin polymer and elastomer films, yet reliable thickness verification of highly compliant materials remains challenging due to deformation from contact-based measurements and the cost and complexity of conventional optical metrology. Accurate thickness control is especially critical in soft elastomer applications such as dielectric elastomer actuators (DEAs), where mechanical and functional performance scales strongly with film thickness. This work presents a low-cost, primarily 3D-printed benchtop spin coater with an integrated, minimally deforming optical thickness measurement system for soft-film fabrication workflows. The system is designed to manufacture films between 50 and 300 microns thick with repeatability within 10 microns. Thickness is measured in-situ by tracking displacement of a reflected laser beam via quadrant photodetector, avoiding significant deformation. Optical geometry, sensor linearity constraints, and structural validation via finite element analysis are discussed. Experimental validation using calibrated metal shims demonstrated a thickness resolution of 3.6-3.7 microns and best-case measurement repeatability of 13 microns (95 percent confidence interval). The platform repeatably produced silicone films within 9 microns of target thickness, demonstrating that accessible optical metrology can be integrated into a low-cost spin coating system for practical, thickness-controlled fabrication of compliant thin films without specialized industrial instrumentation.
Daniel Gliksberg, Jiajie Qiu, Jun Suzuki +1
Aug 13, 2026cs.CV
3D body scanning has become an important tool in healthcare applications because of its rapid and non-invasive nature. While smartphone-based photogrammetric reconstruction provide a low-cost and accessible alternative to commercial 3D body scanners, their performance for whole-body scanning remains insufficiently validated. Thus, we designed this study to comprehensively validate the photogrammetric 3D scanning application by evaluating automatically extracted whole-body measurements and longitudinal body-shape monitoring. We evaluated a representative application, PolyCam, against the commercial depth-sensor-based Fit3D ProScanner using 144 pregnant participants scanned longitudinally throughout pregnancy. We designed an automatic circumference extraction pipeline to get measurements at four anatomical landmarks from paired 3D scans. A linear mixed-effects model was used to evaluate scanner effects and longitudinal body-shape changes. Measurement consistency was assessed using repeated PolyCam scans and tape measurements on a rigid mannequin. PolyCam demonstrated strong agreement with Fit3D, with average biases below 16 mm, intraclass correlation coefficients above 0.8, and Pearson correlation coefficients above 0.9 across all landmarks. Both systems captured comparable longitudinal body-shape changes. Mannequin experiments showed mean biases below 3.5 mm and no significant differences from tape measurements. These findings support smartphone photogrammetry as a potential accessible alternative to commercial body scanners and applicable for longitudinal 3D body-shape assessment.
Ruting Cheng, Boyuan Feng, Chuhui Qiu +4