cs.CVSep 13, 2026

Mobile CT Services for Rural, Regional, and Remote Areas: Current Practice and Future Integration with Telehealth and Regulatory-Authorised AI

Authors: Zhicheng Lu, Md Zahid Islam, M Mamun Huda, Kristie Sweeney, Shayne Chau, Oliver Mulcock, Corey Hemopo, Catherine Keniry, 

Organizations: Rural Health Research Institute, Charles Sturt University, Orange, NSW 2800, Australia · Artificial Intelligence and Cyber Futures Institute, Charles Sturt University, Bathurst, NSW 2795, Australia · School of Rural Medicine, Charles Sturt University, Orange, NSW 2800, Australia · Western NSW Local Health District, Bathurst, NSW 2795, Australia · 

Abstract

Computed tomography (CT) plays an essential role in clinical workflow to improve patient outcomes. However, access to CT imaging and specialist interpretation remains limited, particularly in rural, regional, remote (RRR), and other resource-limited settings. Recent advances in mobile CT, telehealth, and artificial intelligence (AI) provide opportunities to extend advanced imaging services to populations in RRR settings. This review examines: 1) mobile CT systems deployed in trucks, trailers, ambulances, and other mobile platforms; 2) telehealth technologies supporting CT-based healthcare; and 3) AI for CT that has received regulatory authorisation or is currently deployed in clinical practice. Applications are evaluated across four clinical functions: screening and diagnosis, patient monitoring, risk prediction, and intervention or therapeutic decision support. The review covers neurological, thoracic, cardiovascular, abdominal, oncological, musculoskeletal, and interventional imaging, with particular attention to stroke, cancer, and other image-guided treatment. Other factors such as regulatory status, deployment status, and estimated technology readiness (TRL) level are compared. Current evidence indicates that mobile CT, telehealth, and AI for conventional CT are individually relatively mature, but fully integration of these technologies remains less widely deployed and validated in the clinical settings. Key barriers include regulatory variation, domain shift, connectivity requirements, cost, workflow integration, cybersecurity, and limited evidence of patient-level benefit. Future research should prioritise prospective, multicentre evaluation of integrated CT systems in real-world and underserved clinical settings.

Figures & tables

Explore similar work

Jul 11, 2026

BAT-RM: A Boundary-Aware Transformer with Region-Aware Multi-Directional Mamba for Clinically Deployed Cervical Cancer Radiotherapy Auto-Contouring

We present a clinically deployed end-to-end auto-contouring system for cervical cancer radiotherapy planning, anchored by the Boundary-Aware Transformer with Region-Aware Mamba (BAT-RM), a hybrid architecture that integrates Sobel-gated boundary attention, a linear-time, multi-directional Mamba module for long-range context, and a boundary-skeleton-guided fusion gate. This design achieves linear-time complexity for long-range context modeling, avoiding the quadratic cost of full spatial self-attention. The full pipeline spans multi-institutional data collection, rigorous inter-rater quality assurance, external validation in an independent cohort, and a web-based clinical interface natively compatible with Varian, RayStation, and Monaco. Against four baselines, BAT-RM achieves superior performance across seven anatomical classes, with statistically significant improvements in target volumes, including GTV and CTV, and in organs at risk such as the rectum and bladder. A prospective multi-center reader study involving 13 radiation oncologists demonstrated that AI assistance elevates junior oncologists' IoU from 0.899 to 0.965, approaching senior-level accuracy, while reducing contouring time by more than 80%. The system also reduced expert consultation rates and improved inter-reader consistency, reflecting gains in both efficiency and quality assurance. Following clinical deployment at a partner hospital, the system reduced patient wait times from days to hours without additional staffing, enabling same-day or next-day initiation of treatment for routine cases. BAT-RM demonstrates that a rigorous research pipeline, from data curation to clinical deployment, can translate directly into measurable patient benefit in resource-constrained settings where the demand for radiotherapy far exceeds specialist capacity.
Jun 10, 2026

MedCTA: A Benchmark for Clinical Tool Agents

To make clinically grounded decisions, medical AI agents are expected to go beyond simple recognition and be capable of tool retrieval, evidence acquisition, and integration. Existing benchmarks largely evaluate isolated perception or single-turn question answering, and therefore provide limited visibility into failures of planning, tool recruitment, and rollout reliability. We introduce MedCTA, a benchmark for evaluating medical tool agents on clinician-validated, step-implicit tasks grounded in realistic multimodal clinical inputs, including radiology images, pathology slides, and reports. MedCTA comprises 107 real-world clinical tasks with clinician-verified executable trajectories over 5 deployed tools, and supports process-aware evaluation of tool selection, argument validity, execution stability, trajectory fidelity, and outcome quality. We benchmark 18 open- and closed-source multimodal models and find that even frontier systems remain brittle in multi-step clinical tool use: autonomous rollouts are dominated by protocol failures, premature stopping, and incorrect tool recruitment, while gold-standard tool routing yields large but still incomplete gains. These results show that strong backbone perception does not translate into reliable agentic behavior in clinical settings. MedCTA provides a rigorous testbed for auditing, diagnosing, and advancing trustworthy medical AI agents. The dataset and evaluation suite are available at https://ivul-kaust.github.io/MedCTA/
Sep 28, 2026

Disentangling Lung-Cancer CT/LDCT AI: A Systematic Evidence Map of Clinical Tasks, Evidence Chains, and Translational Gaps

Artificial-intelligence studies using computed tomography (CT) for lung cancer are often broadly labelled "prediction" despite addressing clinically distinct tasks. We systematically mapped CT/low-dose CT (LDCT)-centered lung-cancer AI using five-database retrieval, full-text eligibility assessment, role-aware modality/omics extraction, clinical-task classification, and a Multi-Tier Evidence Graph (MTEG). The final corpus comprised 293 studies (2016-2026): 230 Detection, 8 future Risk-prediction, and 55 Other studies. Clinical variables (96.2%), 3D CT/LDCT (73.0%), and radiomics (63.5%) predominated, whereas external validation (29.0%), calibration (20.5%), decision-curve analysis (13.0%), longitudinal CT (17.7%), and saliency/attribution XAI (21.5%) were less frequent. The MTEG comprised 377 nodes and 3,444 edges; only 31 studies (10.6%) completed the six-tier substantive evidence chain, with greatest attrition at reasoning/explanation. Overall, the literature is detection-dominated, genuine future risk prediction remains uncommon, and complete translational evidence chains are rare.