cs.ROSep 13, 2026

A Personalized Dynamic Balance Evaluation Paradigm for Hip Exoskeleton-Assisted Walking under Unexpected Ground Perturbations

Authors: Yun ChenOluwasegun T. AkinniyiQiang Zhang

Abstract

Hip exoskeletons may improve recovery from unexpected gait perturbations, yet personalizing assistance remains difficult because balance is multidimensional and human-in-the-loop experiments are small-sample and noisy. We present a participant-specific composite balance cost that integrates seven biomechanical sub-metrics spanning margin of stability, center-of-mass dynamics, and whole-body angular momentum. The sub-metrics are converted to direction-aligned, dimensionless cost features, and nonnegative fusion weights are learned on the simplex. Coupled with an empirical-Bayes hierarchical model, the learned-composite selector estimates each tested condition's posterior probability of being best, P(best), and a high-probability candidate set with size K0.8K_{0.8}. The framework was evaluated with three participants walking at 1.1 m/s during unilateral belt-slip perturbations across 46 hip-assistance conditions. In the full-budget analysis (B = 4 repeats per condition), the selector concentrated 80% of the posterior probability within 1 to 5 of 46 conditions, compared with 2 to 12 for equal-weight fusion and 4 to 37 for principal component analysis fusion. This smaller candidate set could shorten personalization experiments and limit participants' exposure to repeated perturbations in future studies. Selected-condition trials showed lower observed composite costs than no-torque trials, with nominal p < 0.05 for P2 and P3. Leave-one-repeat-out refits yielded positive mean held-out rank correlations for all participants and moderate stability of the learned weights and candidate sets. These proof-of-concept results support participant-specific composite balance evaluation for candidate selection in perturbation-based human-in-the-loop experiments.

Explore similar work

Aug 1, 2026cs.RO

First Deployable Dynamic-CoM: A Unified Policy and Method-Agnostic Benchmark for Humanoid Single-Leg Balance

Unified humanoid policies handle agile whole-body motion, yet stumble on a simple demand: staying balanced on one leg. On our single-leg-balance benchmark, eight released state-of-the-art general policies hold a clean single-leg stance on 0 of 90 test motions; they stay up only by stepping or hopping, recovering from imbalance rather than preventing it. Prevention needs the capture point (xCoM), the center of mass (CoM) extrapolated by its velocity, which has never driven a hardware policy because it requires a base linear velocity no on-board sensor provides; expressed relative to the support foot, that velocity cancels exactly, leaving an observation reconstructible from encoders and IMU alone. We put this first deployable dynamic-CoM observation directly into the actor that runs on hardware, and pair it with a reward library translated term by term from human postural control, under one principle: prevention over repair. Trained by asymmetric FastSAC with a privileged critic and no distillation, the resulting policy, FDDC (First Deployable Dynamic-CoM), holds clean single-leg balance on 86 of 90 held-out motions across nine stratified pose classes and transfers to a real Unitree G1; in ablation, the dynamic-CoM observation is the single largest driver: removing it alone costs 40 points of clean single-leg balance. We release the full stack with the first method-agnostic, reproducible sim2sim benchmark for humanoid single-leg balance, scoring each policy in a simulator distinct from its training one, a step toward turning balance from a per-task trick into a capability the field can measure.
Yikai Zhou, Xingyun Wang, Jieming Cui +4
Aug 1, 2026cs.RO

Staged Multi-Agent Training (SMAT) for Hip Exoskeletons: Metabolic and Biomechanical Validation of a Simulation-Trained Co-Adaptive Controller

Learning-based controllers can deliver exoskeleton assistance after training entirely in physics-based simulation, yet few controllers that address human-device co-adaptation have been validated on real users by whole-body metabolic measurement, the standard benchmark for assistive walking. Co-adaptation is challenging: as the device alters joint dynamics, the wearer reorganizes neuromuscular coordination, producing a non-stationary learning problem. Staged Multi-Agent Training (SMAT), a four-stage curriculum that progressively trains a musculoskeletal human actor and a bilateral hip exoskeleton actor, was introduced and shown to reduce simulated hip-muscle activation and provide positive assistance on hardware. This article provides the first physiological validation of SMAT. The policy was deployed on a hip exoskeleton and tested with eight healthy adults, with metabolic cost measured by indirect calorimetry across no-exoskeleton, passive, and active conditions. Active assistance lowered net metabolic rate by 19.7% relative to the passive device (p < 0.001). Biomechanical analysis confirmed predominantly positive hip mechanical power across all subjects (positive-power ratio 0.98), and the policy generalized across walking speeds and terrains. Together, these results show that a single simulation-trained SMAT policy, deployed without subject-specific retraining, delivers a significant metabolic benefit on real users while remaining robust beyond the conditions it was trained on.
Yifei Yuan, Jakob Wolf, Ghaith Androwis +1
Jul 8, 2026cs.RO

Generating Personalized Lower-Limb Kinematics Across Walking Speeds Using Subject-Conditioned Diffusion

Personalizing exoskeleton assistance requires user-specific gait data across many locomotor tasks, yet collecting this data demands repeated motion capture sessions that are costly, time-intensive, and especially burdensome for clinical populations. This challenge is most acute across walking speeds, where gait changes substantially and deviates further in clinical gait. This work introduces a subject-conditioned residual diffusion framework that generates personalized lower-limb kinematics at unseen walking speeds from a subject's gait sequence at a single seen speed. Given sagittal-plane hip, knee, and ankle trajectories at a seen speed and a desired unseen speed, the model generates a residual that transforms the seen trajectory into the unseen one, using a transformer denoiser conditioned on the subject's gait and the two speeds through feature-wise linear modulation. Trained only on able-bodied data, the model achieved a mean absolute error (MAE) of 3.4° on held-out able-bodied subjects. Without any stroke-specific fine-tuning, it achieved a 6.0° MAE on out-of-training-distribution stroke subjects, retaining subject identity for clinical gait. The framework reduced the MAE by over 70% relative to supervised feed-forward baselines, and a single seen speed matched the accuracy of four speeds within 0.4°. These results demonstrate that subject-conditioned residual diffusion can synthesize personalized gait across speeds from minimal data, reducing the collection burden for downstream exoskeleton personalization.
Diya Dinesh, Adrian Krieger, Changseob Song +3