cs.CVSep 18, 2026

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

Authors: Mushir Akhtar, M. Tanveer, Mohd. Arshad

Organizations: Department of Mathematics, Indian Institute of Technology Indore, India

Abstract

A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.

Figures & tables

Explore similar work

Jun 16, 2026

Vision-language models for chest radiography do not always need the image

Vision-language models that answer questions about chest radiographs are evaluated by their accuracy on labels derived from radiology reports. High benchmark accuracy is often interpreted as evidence that the model uses the image. A model that answers from the finding named in the question can score as well as a model that uses the radiograph. Keeping the question fixed, we audit eight open-weight systems by swapping in another patient's radiograph with the same or the opposite label, occluding the radiologist-marked region or an equal region elsewhere, and removing the radiograph or replacing it with noise or a photograph. On 2,548 yes-or-no questions from MIMIC-CXR, one multimodal model answers Yes regardless of the image, another multimodal model changes its answers without following the label, and four systems use the image but keep about half of their correct answers when the radiograph is swapped for an opposite-label radiograph. A medical model that receives only the question text scores 55.3% on the pooled questions, higher than two multimodal systems. It scores 91.8% where every finding is present, and answering Yes to every question scores 100% there. Where the image is necessary, the best multimodal system exceeds this model by 10.4% in balanced accuracy. The categories are unchanged on CheXpert. Confidence is not higher when a correct answer depends on the marked region. In a reader study with three radiologists, the two radiologists who read a balanced set of 200 cases score 86.0% and 82.0%, and the systems score 50.0% to 73.0%. Accuracy does not establish image use, but an intervention on the image can test it.
Aug 1, 2026

Auditing Medical Vision-Language Models on Chest Radiographs: Estimating Reference Agreement Across Institutions

Vision-language models return structured chest-radiograph findings through interfaces exposing no confidence score, so a receiving institution cannot read off how far to trust an individual judgment. Whether agreement with an institution's reference standard transfers across sites, findings, prediction directions and question formats is largely unmeasured. We evaluated three generative vision-language models on three institutional chest-radiograph corpora and six findings under two elicitation protocols, comprising more than 345,000 finding-level predictions, and estimated finding-by-direction reference agreement at a receiving institution from a small budget of local labels. Estimation strategies were then stress-tested under repeated strict institution-held-out evaluation. Under evaluation excluding the receiving institution from development entirely, adaptive selection among the seven estimators that design admits did not improve on simple fixed alternatives: it achieved a mean Brier score of 0.1083, against 0.0853 for always using a Beta-Binomial empirical-Bayes estimator and 0.0855 for a target-only logistic model. Those two differ by 0.0003, less than this family's own sensitivity to a change of solver version, and each leads in about half the settings, so no default can be recommended. Their advantage over estimators pooling across institutions was concentrated at one site and not confirmatory once clustered by institution, and a plug-in empirical-Bayes posterior-predictive count interval at a nominal 95% level covered 87.0%, less at the hardest institution. Reference agreement therefore has to be re-evaluated per site and per interface; these results concern agreement with institutional labels, not clinical correctness.
Sep 24, 2025

Revisiting Performance Claims for Chest X-Ray Models Using Clinical Context

Public datasets of Chest X-Rays (CXRs) have long been a popular benchmark for developing machine learning (ML) computer vision models in healthcare. However, the reported strong average-case performance of these models do not necessarily reflect their actual utility when used in heterogeneous clinical settings, potentially masking weaker performance in medically significant scenarios. In this work we use clinical context to provide a more holistic evaluation of models for CXR diagnosis. In particular, we use discharge summaries, recorded prior to each CXR, to derive a ``pre-CXR'' probability of each CXR label, as a proxy for existing contextual knowledge available to clinicians when interpreting CXRs. We use this measure to probe model performance along two dimensions: First, using a stratified analysis, we show that models tend to have lower performance (as measured by AUROC and other metrics) among individuals with higher pre-CXR probability. Second, by controlling for pre-CXR probability via matching and re-weighting, we demonstrate that performance degrades when the correlation is broken between prior context and the current CXR label, suggesting that model performance is highly sensitive to the underlying distribution of clinical context. Specifically, cases with high pre-test probabilities present a fundamentally more difficult visual classification task, highlighting a gap in clinical utility when models are applied to high-risk cohorts.