Shadow Reduction in Ultrasound Imaging Using Differentiable Simulation and Radiance Field Decomposition

Authors: Valentin Bacher, Pak Hei Yeung, Bernhard Kainz, Madeleine K. Wyburd, Nicola K. Dinsdale, Michael Gray, Ana I. L. Namburete

Organizations: Oxford Machine Learning in NeuroImaging Lab, University of Oxford, United Kingdom · Oxford Machine Learning in NeuroImaging Lab, Department of Computer Science, University of Oxford, OX1 3QD, United Kingdom · Quantitative Healthcare Analysis · Quantitative Healthcare Analysis (qurAI) Group, Informatics Institute, University of Amsterdam, Amsterdam, 1098 XH, The Netherlands · Friedrich-Alexander-Universität Erlangen-Nürnberg, Germany · Imperial College London, United Kingdom · Imperial College London, 180 Queen’s Gate, London, SW7 2AZ, United Kingdom · Department of Computer Science, University of Copenhagen, Denmark · Institute of Biomedical Engineering, University of Oxford, United Kingdom · Institute of Biomedical Engineering, University of Oxford, Marcela Botnar Wing, Oxford, OX3 7LD, United Kingdom

Abstract

Acoustic shadows from bone and other highly attenuating tissues obscure clinically important structures in ultrasound. In fetal brain imaging, skull-induced artefacts disproportionately degrade the hemisphere closer to the transducer (proximal), limiting symmetric assessment of the two hemispheres. Existing correction methods require raw scanner data, impose restrictive assumptions on tissue properties, or rely on generative models that may hallucinate anatomy. We present RFlash, a physics-informed post-processing method that decomposes beamformed ultrasound images into explicit attenuation and scatter-intensity maps using a differentiable radiance-field formulation of image formation. Attenuation-adaptive re-rendering then removes the dependence of the signal at each depth on the intervening tissue, equivalent to virtually advancing the transducer into the tissue. Across 1,261 3D fetal brain volumes, 143 real 2D curvilinear abdominal scans, and 1,200 simulated 2D linear-probe liver scans, RFlash reduces shadow-related intensity differences more effectively than classical Hughes-Duck attenuation correction. For a gestational-age model trained on the distal hemisphere (further from the transducer) and applied to the proximal hemisphere, prediction error decreases by 5.1 days (40%) relative to the original images. The estimated attenuation maps also yield shadow-confidence maps that improve random-forest bone-shadow segmentation over the image alone and receive greater SHAP importance than an existing neural confidence-map baseline, suggesting greater physical consistency. RFlash requires neither hardware modification nor access to raw scanner data and supports 2D and 3D acquisitions with linear and curvilinear probes, making it widely applicable allowing clinicians to use our method on their already acquired scanners and images.

Figures & tables

Appendix figures & tables9 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 26, 2026cs.CV

Focus on What Matters: Two-Stage ROI-Aware Refinement for Anatomy-Preserving Fetal Ultrasound Reconstruction

Measurement-critical ultrasound tasks often depend on a small anatomical region, making global reconstruction metrics an unreliable proxy for clinical fidelity. We propose an ROI-aware representation learning framework and instantiate it for first-trimester nuchal translucency (NT) screening under multi-hospital domain shift. A two-phase convolutional autoencoder (CAE) first learns a globally faithful 128-D latent code via MS-SSIM, then refines the NT ROI using intensity (L1) and normalized Sobel-edge constraints. To combine these heterogeneous objectives without manual tuning, we initialize loss weights via gradient-based calibration from per-term gradient magnitudes. Under strict hospital-wise evaluation with one hospital held out, ROI refinement improves both global and measurement-relevant quality: on the standard dev split it increases PSNR by +0.27 dB (val) and +0.29 dB (held-out test), reduces ROI MAE by 8.87% (val) and 6.43% (held-out test), and reduces ROI Edge-MAE by 11.10% on source hospitals and 4.90% on the unseen hospital. Beyond reconstruction, frozen-latent probes provide additional evidence of generalization: hospital provenance becomes less confidently predictable on the unseen site (0.556 to 0.541 max-softmax; 0.684 to 0.688 entropy) while OOD detection remains strong across site-held-out protocols (Mahalanobis AUROC up to 0.9956, with modest KNN gains in challenging splits). The same ROI-aware refinement principle is anatomy-agnostic and can be adopted for other fetal biometry targets (e.g., crown-rump length (CRL), nasal bone (NB)) and broader medical imaging settings where small ROIs dominate clinical decisions.
Sep 11, 2026cs.CV

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.
Sep 23, 2026eess.IV

Physics-Guided Multi-Objective Deep Learning for Ultrasound RF Data Interpolation in Resource-Constrained Imaging

Ultrasound imaging increasingly targets portable, point-of-care, and wearable settings where constraints on power, bandwidth, and hardware complexity often necessitate sparse data acquisition in spatiotemporal scanning. However, image reconstruction using the sparse data can introduce insufficient phase information in coherent beamforming process, resulting in grating-lobe artifacts that degrade imaging contrast resolution. We present a physics-guided, data-driven framework for sparse-to-dense radio-frequency (RF) reconstruction that aligns training with downstream image formation. Our approach trains an end-to-end interpolation network using a hybrid supervision scheme that combines an RF-domain and a beamforming-domain loss with exponential moving average (EMA) to stabilize the multi-objective training. To improve generalization under variable acquisition layouts, we also introduce a random-skip masking strategy that varies sparsity patterns during training so a single model can handle diverse decimation factors and irregular channel configurations. We evaluate the framework on a held-out test set using the mean structural similarity index measure (SSIM) between reconstructed and ground-truth beamformed images. Across decimation factors ×2\times 2 to ×13\times 13, the best-performing configuration maintains mean SSIM around 0.95. Overall, the results show consistent gains in RF reconstruction and post-beamforming image quality across diverse acquisition conditions. This approach enables robust, high-quality ultrasound imaging at resource-constrained settings by allowing more sparse scanning in spatiotemporal domain.