stat.APSep 12, 2026

Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration

Authors: Shayma Alkobaisi, Anas Ali

Organizations: Department of Computer Science and Software Engineering, United Arab Emirates University, Al Ain, United Arab Emirates · Department of Computer Science, National University of Modern languages, Lahore, Pakistan

Abstract

Low-cost indoor air-quality sensors could support personalized asthma prevention, but their nonlinear measurement error, delayed exposure effects, time-varying confounding, and heterogeneous lower-tail responses limit risk estimation. We present CAUSALQUANT-ASTHMA, a measurement-error-aware causal quantile distributed-lag framework for short-horizon peak expiratory flow analysis. Sparse reference measurements train a nonlinear calibration model; stabilized sequential generalized-propensity weights address measured exposure assignment; and a susceptibility-modulated, smooth, noncrossing quantile model estimates lag-specific and sustained-exposure contrasts. Because no authorized cohort simultaneously provided dense indoor sensing, reference co-location, and outcome-compatible longitudinal data, evaluation used five semi-synthetic panels with known counterfactual truth, 150 patients and 12,600 patient-days per realization. Across eight methods, CAUSALQUANT achieved a dose-response integrated absolute error of 0.304 plus or minus 0.094, improving 24.2 percent over the strongest measurement-error and propensity-weighted baseline. It also obtained the lowest overall pinball loss, 1.065, while maintaining zero quantile crossings and 78.1 percent coverage for the nominal 80 percent interval. Sensor calibration reduced held-out exposure RMSE by 33.7 percent. Stress tests quantified degradation under sensor noise, missing personal measurements, and hidden confounding. These findings establish methodological feasibility and reproducibility, not clinical effectiveness; prospective, governance-approved external validation is required before patient-level interpretation or deployment.

Figures & tables

Explore similar work

Apr 23, 2026

A temporal deep learning framework for calibration of low-cost air quality sensors

Low-cost air quality sensors (LCS) provide a practical alternative to expensive regulatory-grade instruments, making dense urban monitoring networks possible. Yet their adoption is limited by calibration challenges, including sensor drift, environmental cross-sensitivity, and variability in performance from device to device. This work presents a deep learning framework for calibrating LCS measurements of PM2.5_{2.5}, PM10_{10}, and NO2_2 using a Long Short-Term Memory (LSTM) network, trained on co-located reference data from the OxAria network in Oxford, UK. Unlike the Random Forest (RF) baseline, which treats each observation independently, the proposed approach captures temporal dependencies and delayed environmental effects through sequence-based learning, achieving higher R2R^2 values across training, validation, and test sets for all three pollutants. A feature set is constructed combining time-lagged parameters, harmonic encodings, and interaction terms to improve generalization on unseen temporal windows. Validation of unseen calibrated values against the Equivalence Spreadsheet Tool 3.1 demonstrates regulatory compliance with expanded uncertainties of 22.11% for NO2_2, 12.42% for PM10_{10}, and 9.1% for PM2.5_{2.5}.
Oct 8, 2026

Low-Cost Sensor Calibration for Indoor Air Quality Monitoring: A Dataset, Evaluation Scenarios, and a Lightweight Model

Low-cost sensors enable scalable indoor air quality monitoring but require calibration because of nonlinear distortions, noise, and temporal drift. The conventional strict pairwise calibration setting requires a co-located reference sensor at each deployment location and does not account for spatial and temporal heterogeneity. To address these limitations, we introduce a six-month dataset comprising multivariate indoor air-quality measurements from low-cost and reference sensors with contextual metadata collected at five locations. Using this dataset, we define four evaluation scenarios. The reference-efficient and location-transfer scenarios evaluate spatial generalization, whereas the long-term drift and event-conditioned scenarios assess robustness to gradual and abrupt distribution shifts. Based on these scenarios, we derive design requirements and propose a lightweight temporal model that combines input-window compression with residual temporal and feature fusion. Experiments show strong calibration performance across all four scenarios with low edge-inference cost.
Sep 17, 2026

Calibration-First Cross-Cohort Multimodal Temporal Learning for Transferable Asthma-Risk Forecasting

Asthma deterioration forecasting must remain reli- able when patient populations, sensor ecosystems, and available modalities change across cohorts. Existing models commonly optimize within-cohort discrimination and may produce poorly calibrated probabilities after transfer. We present CALIBRA, a calibration-first multimodal temporal framework for short- horizon risk prediction with incomplete data. Dedicated recurrent encoders process environmental, pulmonary, symptom, medication, wearable, and context streams; a reliability-conditioned gate suppresses stale or absent modalities, while gradient-reversal training discourages avoidable cohort signatures. A shrinkage- based hierarchical logistic layer calibrates probabilities using a patient-disjoint target subset, and split conformal prediction provides abstention-capable prediction sets. To avoid fabricating clinical evidence, we evaluate the complete implementation on a documented three-cohort semi-synthetic benchmark with controlled distribution shift, informative missingness, and sealed target patients. Across five configured seeds, CALIBRA achieved mean target-test AUPRC 0.224 versus 0.240 for the strongest non-ablation comparator, TemporalTransformer; mean AUROC was 0.717, and Brier score was 0.098. Experiments additionally assess complete-modality failures, calibration, conformal coverage, decision curves, subgroup behavior, ablations, runtime, and parameter count. The results verify the method and reproducible pipeline under controlled shift, but do not establish clinical effectiveness. External validation on harmonized real asthma. Overall this artifact provides evidence for carefully governed real-cohort validation.