cs.LGSep 27, 2026

A Free Knob: Decoupling Calibration and Predictive Skill in Threshold-Based Evaluation

Authors: Md Tanveer Hossain Munim, Bijoy Ahmed Saiem, Al-Amin Sany, Tanzima Hashem

Organizations: Regional Integrated Multi-Hazard Early Warning System (RIMES) · Bangladesh University of Engineering and Technology (BUET)

Abstract

Many dense-prediction benchmarks evaluate rare events by pooling prediction and target over spatial blocks, thresholding each, and scoring the contingency table. At a fixed rare operating point, the max-pooled Critical Success Index (CSI) confounds spatial discrimination with amplitude calibration: sharp observations promote many blocks above threshold, while attenuated predictions from squared-error regression leave the same blocks below it. We repurpose classical monotone calibration as a symmetric audit: a post-hoc transform fitted on held-out data and applied separately to each system. The transform cannot reverse pixel ordering, so any contrast it reproduces cannot establish improved spatial ranking. On SEVIR, two released checkpoints of one architecture differ by -29.5% in extreme-threshold CSI before the control and by +5.3% after it. Across 450 pairwise contrasts among 6 systems, the difference in pooled frequency-bias deviation is associated with how far the CSI contrast moves under the control (r = +0.796), and 51 contrasts reverse sign. At CasCast's published extreme-event operating point, the cascade-over-backbone CSI gap falls from 0.1601 to 0.0339, a 78.8% reduction; the remaining gap stays positive. The effect persists when the transform is fitted on a window before the test period, and calibration also reveals advantages hidden by a better-calibrated baseline. On geostationary infrared imagery the relative gain grows as events become rarer, crowd counting reproduces the bias-gain relationship under patch-sum pooling, and semantic segmentation, where frequency bias is already near one, shows little average change. The confound therefore requires both a fixed operating point and a training regime that leaves the output miscalibrated there. We recommend reporting pooled frequency bias and a symmetric held-out FreeKnob Audit alongside rare-event pool-and-threshold scores.

Figures & tables

Appendix figures & tables13 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 3, 2026cs.LG

Beyond ECE: Calibrated Size Ratio, Risk Assessment, and Confidence-Weighted Metrics

Confidence calibration has been dominated by the Expected Calibration Error (ECE), a linear metric that counts calibration offset equally regardless of the confidence level at which it occurs. We show that ECE can remain small even under arbitrarily large overconfidence risk, so we propose Calibrated Size Ratio (CSR) instead, an interpretable metric that equals 1 under perfect calibration, from which we derive the risk probability PriskP_{\mathrm{risk}} that quantifies the statistical evidence for overconfidence. We further argue that overconfidence risk assessment must be complemented by a measure of discriminative value: whether the assigned confidences actively distinguish correct from incorrect predictions. We show that confidence-weighted accuracy cwA\mathrm{cwA} is the natural such complement, and that confidence-weighting extends to all standard classification metrics. In particular, we prove that the confidence-weighted AUC (cwAUC) captures the information about calibration while the classical AUC cannot. We validate the proposed indicators on several synthetic confidence distributions under multiple controlled calibration profiles and find that CSR separates risky from non-risky assignments. We also test the metrics on fifteen real datasets, with and without post-hoc calibration, and find that standard methods can yield risky confidence profiles.
May 28, 2026cs.LG

CalArena: A Large-Scale Post-Hoc Calibration Benchmark

Reliable probability estimates are critical in many machine learning applications, yet modern classifiers are often poorly calibrated. Post-hoc calibration provides a simple and widely used solution, but the large number of proposed methods, combined with small-scale and inconsistent evaluations, makes it difficult to determine which approaches are truly effective in practice. We introduce a large-scale, standardized benchmark for post-hoc calibration, covering nearly 2000 experiments across tabular and computer vision tasks, including binary, multiclass, and large-scale classification settings. Our benchmark aggregates predictions from a diverse set of classical models, modern deep learning architectures, and foundation models, and provides unified, reproducible implementations of dozens of calibration methods within a common evaluation framework. We argue that Post-Hoc Improvement (PHI) in proper scoring rules offers a principled alternative to traditional calibration error estimators for comparing post-hoc methods, capturing both calibration quality and potential degradation to the model's predictive performance. Using this framework, we conduct the most comprehensive empirical study of post-hoc calibration to date. Our results reveal consistent patterns across domains: smooth calibration functions outperform binning-based approaches, dedicated multiclass methods are essential in high-dimensional settings, and generic machine learning models are not competitive without calibration-specific design. To facilitate future research, we release all data, code, and evaluation tools, providing a plug-and-play benchmark for developing and comparing calibration methods.
May 9, 2026cs.LG

RareCP: Regime-Aware Retrieval for Efficient Conformal Prediction

Recent advances in uncertainty quantification for time series forecasting show that conformal prediction can provide reliable prediction intervals, yet standard conformal methods are often inefficient under temporal dependence, drift, and heterogeneous error behavior. Existing methods typically either update miscoverage rates over time or learn unconstrained calibration weights, without explicitly separating two central sources of nonstationarity: smoothly drifting error distributions and co-existing distinct error regimes. We introduce RareCP, a regime-aware retrieval method for adaptive conformal time series prediction. RareCP learns local calibration representations through a mixture of cosine-attention experts that each capture distinct error regimes, while a compact hypernetwork adapts the kernel parameters to track temporal drift. Given a new forecasting context, RareCP retrieves the top-k most relevant calibration examples, assigns similarity weights, and forms a weighted conformal quantile over their signed residuals, yielding asymmetric prediction intervals. The adaptive kernel is trained using a smooth interval score objective, with a parameter-space anchor to a lightweight teacher kernel to preserve stable local representations. On the GIFT-Eval benchmark, RareCP improves interval efficiency over recent conformal baselines and foundation model uncertainty estimates while maintaining empirical coverage. Ablations confirm that regime-specific experts, drift-adaptive kernels, sparse retrieval, and teacher anchoring each contribute to the final performance.