cs.CVOct 22, 2026

ICGF-CXRMate: Image-Conditioned Clinical Context Compression and Gated Fusion for Chest X-ray Report Generation

Authors: Vu Minh Tran, Thuc Huynh, Son Thanh Luu, Doanh C. Bui

Organizations: University of Information Technology · Viet Nam National University Ho Chi Minh City

Abstract

Auxiliary patient data can improve chest X-ray report generation, but directly concatenating heterogeneous clinical information with visual tokens produces long, variable-length decoder prompts and may expose the model to redundant or image-irrelevant context. We propose ICGF-CXRMate, an image-conditioned clinical context compression and gated fusion framework. Learnable queries are first conditioned on the current chest X-ray representations and then attend to the patient-data sequence, compressing it into a fixed number of clinical context tokens. Gated cross-attention selectively integrates these tokens into the visual stream, while the compressed tokens are retained in the decoder prompt as a direct clinical pathway. Experiments on linked MIMIC-CXR and MIMIC-IV-ED examinations show that ICGF-CXRMate improves report quality while reducing the average prompt length. In Stage2, it improves RadGraph-F1 from 24.00 to 28.86, CXR-BERT similarity from 56.86 to 62.80, and BLEU-4 from 5.14 to 7.96 compared with CXRMate-ED, while reducing the average prompt length from 373.89 to 288.37 tokens, corresponding to a 22.9% reduction. After self-critical sequence training, ICGF-CXRMate outperforms CXRMate-ED on six of eight report-quality metrics in Stage3. Ablation studies confirm the complementary contributions of image-conditioned compression, gated fusion, and direct retention of the compressed clinical tokens.

Figures & tables

Explore similar work

Apr 21, 2026

CXRMate-2: Structured Multimodal Temporal Embeddings and Tractable Reinforcement Learning for Clinically Acceptable Chest X-ray Radiology Report Generation

Chest X-ray (CXR) radiology report generation (RRG) models have shown rapid progress on automated metrics, yet their clinical utility remains uncertain due to limited qualitative evaluation by radiologists. We present CXRMate-2, a state-of-the-art CXR RRG model that enables tractable reinforcement learning (RL) through structured multimodal temporal embeddings and high-resolution visual feature compression, for efficient, unified conditioning of an LLM decoder on visual, textual, and temporal context from a study and its prior. This enables group relative policy optimisation (GRPO), where a proposed reward function is used to improve semantic alignment with radiologist reports. Across the MIMIC-CXR, CheXpert Plus, and ReXgradient datasets, CXRMate-2 achieves statistically significant improvements over strong benchmarks, including gains of 11.2% and 24.4% in GREEN and RadGraph-XL, respectively, on MIMIC-CXR relative to MedGemma 1.5 (4B). To directly compare CXRMate-2 against radiologist reporting, we conduct a blinded, randomised qualitative retrospective evaluation. Three consultant radiologists compare generated and radiologist reports across 120 studies from the MIMIC-CXR test set. Generated reports were deemed acceptable (defined as preferred or rated equally to radiologist reports) in 45% of ratings, with no statistically significant difference in preference rates for seven of the eight analysed findings. Preferences for radiologist reports were driven primarily by higher recall, while generated reports were consistently preferred for readability. Together, these results define a clear pathway to clinically acceptable CXR RRG. Improving recall and the detection of subtle findings represents the primary remaining barrier to non-inferiority with radiologist reporting, positioning CXR RRG for prospective evaluation in assistive, radiologist-led workflows.
Oct 20, 2026

CPVB-RG: Cross-Prior Visual Bridging for Prior-Aware Chest X-Ray Report Generation

Radiologists interpret follow-up chest X-rays by comparing current and prior examinations to identify new, resolved or progressing findings. Most report generation systems either omit this longitudinal context or fuse prior features without distinguishing interval changes from anatomy that remains stable over time. We propose CPVB-RG, a prior-aware framework that combines current and prior radiographs with available clinical text. Its Cross-Prior Visual Bridge (CPVB) contains Progression-Guided Focus Attention (PGFA) and two Cross-Attention units. PGFA is designed to contrast progression-difference attention with shared-spatial attention, aiming to reduce invariant responses whilst retaining coarse spatial correspondence between examinations. The Cross-Attention units then connect the resulting longitudinal visual evidence with clinical semantics. CPVB-RG is trained in two stages, using prior-guided image-text alignment followed by autoregressive report generation with a lightweight language decoder. Experiments on MIMIC-CXR and IU X-Ray show consistent improvements across language and clinical metrics. On MIMIC-CXR, CPVB-RG achieves 0.2847 F1RadGraph and 0.6692 VLScore, with statistically significant gains over the closest decoder-matched prior-aware baseline. These results support the effectiveness of the proposed difference-aware and spatially guided fusion design for prior-aware chest X-ray report generation.
Aug 4, 2026

CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement

A clinically useful chest X-ray system must go beyond fluent report generation: it should classify findings with tunable decision thresholds, localize them spatially, and derive the anatomical measurements upon which many diagnoses depend. Today's Vision-Language Models (VLMs) treat these as separate problems, if they address them at all, leaving a gap between what radiologists need and what generative models provide. We introduce CARE-X, a chest X-ray VLM that narrows this gap by unifying auxiliary discriminative supervision with reward-aligned generation. CARE-X augments its generative backbone with focal-loss classification and composite-loss grounding heads, co-trained alongside the language-modeling objective. This auxiliary supervision produces discriminative diagnostic predictions with tunable decision thresholds and precise spatial localization while also improving report quality, providing evidence that structured prediction and generation reinforce one another. Building on this foundation, Decoupled Clip and Dynamic Sampling Policy Optimization (DAPO) leverages task-specific reward signals for report generation, visual question answering (VQA), and spatial grounding, directly optimizing the clinical quality metrics that matter in practice. The result is state-of-the-art performance on the majority of metrics across four report-generation benchmarks, 94.0% VQA accuracy on ReXVQA (+6.0 pp over the next-best baseline), and generative spatial decoding that reaches near parity with dedicated detection heads. Separately, to address measurement-dependent diagnoses, we couple Qwen3-VL-4B-Instruct with native tool-calling capabilities for invoking deterministic measurement tools, while retaining full visual access to the image. This hybrid inference yields +43.6 pp average F1 over perception-only baselines across five measurement-dependent conditions.