Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI
Organizations: Dept. Molecular Medicine and Surgery, Karolinska Institutet, Karolinska Universitetssjukhuset Solna (L1:00), Stockholm, 171 76, Sweden. · Department of Physics, University of Greifswald, Felix-Hausdorff-Str. 6, Greifswald, 174 89, Germany. · Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, 7820436, Chile. · School of Electrical Engineering and Informatics, Bandung Institute of Technology, Jl. Ganesha No. 10, Bandung, 40132, West Java, Indonesia. ·
Abstract
4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.
Figures & tables
| Group | Case | Sex | Age | Voxel size [mm] | [ms] | Scanner | Stenosis | |
|---|---|---|---|---|---|---|---|---|
| Healthy | H1 | F | 25 | (0.9821, 0.9821, 1.0) | 7 | 82.6 | Prisma | – |
| H2 | M | 31 | (0.9821, 0.9821, 1.0) | 6 | 82.6 | Prisma | – | |
| H3 | M | 29 | (0.9821, 0.9821, 1.0) | 7 | 82.6 | Prisma | – | |
| Moderate | M2 | M | 35 | (0.9821, 0.9821, 1.0) | 9 | 86.8 | Skyra | RMCA |
| M1 | M | 61 | (0.9821, 0.9821, 1.0) | 7 | 86.8 | Skyra | RMCA | |
| M3 | M | 65 | (1.0417, 1.0417, 1.0) | 13 | 42.7 | Skyra | BA |
| Case | [m/s] | VENC [m/s] | ||||
|---|---|---|---|---|---|---|
| H1 | 1.62 | 1.7 | 25 | 13 | 19,109 | 3,107 |
| H2 | 1.21 | 1.3 | 21 | 11 | 19,371 | 3,185 |
| H3 | 0.99 | 1.2 | 25 | 13 | 20,951 | 3,422 |
| M1 | 1.29 | 1.3 | 35 | 18 | 22,672 | 3,687 |
| M2 | 1.28 | 1.3 | 27 | 14 | 14,037 | 2,371 |
| M3 | 5.06 | 5.1 | 26 | 13 | 26,040 | 4,192 |
| Severity | Subject | Model | Train time | MAE [m/s] | DE [%] | MRE [%] | vNRMSE |
|---|---|---|---|---|---|---|---|
| Healthy | H1 | INR | 1.5 min | 0.111 | |||
| PINN | 126 min | 0.111 | 3.0 | 31.12 | 0.083 | ||
| H2 | INR | 1.7 min | 0.109 | ||||
| PINN | 135 min | 0.104 | 2.4 | 30.73 | 0.109 | ||
| H3 | INR | 1.5 min | 0.085 | 0.111 | |||
| PINN | 125 min | 0.085 | 2.6 | 30.66 | 0.111 |
| Severity | Model | Train time | Inference | MAE [m/s] | DE [%] | MRE [%] | vNRMSE |
|---|---|---|---|---|---|---|---|
| Healthy | Interpolation | – | – | ||||
| 4DFlowNet | 30 h | 11.8 s | |||||
| GAN-Gen | 49 h | 12.1 s | |||||
| INR | 1.6 min | 1.6 min | 0.103 | ||||
| PINN | 129 min | 129 min | 2.8 | 30.95 | 0.094 | ||
| Moderate | Interpolation | - | - |
| Subject | Model | Initialization | Train time | MAE [m/s] | DE [%] | MRE [%] | vNRMSE |
|---|---|---|---|---|---|---|---|
| H3 | INR | OPTIMAL | 0.5 min | 0.093 | 2.6 | 32.39 | 0.122 |
| META | 0.5 min | 0.089 | 3.0 | 31.70 | 0.116 | ||
| PINN | OPTIMAL | 4.2 min | 0.146 | 5.4 | 43.49 | 0.183 | |
| META | 4.2 min | 0.095 | 3.1 | 32.69 | 0.128 | ||
| M3 | INR | OPTIMAL | 0.5 min | 0.162 | 8.0 | 38.06 | 0.070 |
| META | 0.5 min | 0.144 | 9.1 | 35.33 | 0.066 |
Medical Image Super-Resolution
Medical image super-resolution reconstructs fine spatial detail from low-resolution scans to support clearer anatomy and more useful clinical measurements.