eess.IVOct 23, 2026

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

Authors: Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, 

Organizations: Dept. Molecular Medicine and Surgery, Karolinska Institutet, Karolinska Universitetssjukhuset Solna (L1:00), Stockholm, 171 76, Sweden. · Department of Physics, University of Greifswald, Felix-Hausdorff-Str. 6, Greifswald, 174 89, Germany. · Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, 7820436, Chile. · School of Electrical Engineering and Informatics, Bandung Institute of Technology, Jl. Ganesha No. 10, Bandung, 40132, West Java, Indonesia. · 

Abstract

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

Figures & tables

Explore similar work

CardsList
  1. Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction

    Sep 29, 2026Mengyuan Xue, Bochun Mei4D ReconstructionAccelerated MRI Reconstruction

  2. FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

    Aug 26, 2026Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan +6Accelerated MRI Reconstruction4D Reconstruction

  3. Prior-Guided Implicit Neural Representations for Single-Subject Diffusion MRI Super-Resolution

    Sep 1, 2026Abdulkader Ghandoura, Marsil Zakour, William Consagra +1Implicit Neural RepresentationsMedical Image Super-Resolution