cs.CVOct 26, 2026

Targeted Deep Regression - Initial Applications in Whole-Body Water-Fat MRI in UK Biobank

Authors: Filip Marttala, Taro Langner, Johan Öfverstedt, Nouman Ahmad, Håkan Ahlström, Robin Strand, Joel Kullberg

Organizations: Radiology, Department of Surgical Sciences, Uppsala University, 752 37, Uppsala, Sweden · Department of Information Technology, Uppsala University, 751 85, Uppsala, Sweden · Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden

Abstract

UK Biobank is a British clinical study which, in addition to large amounts of medical data collected, plans to include detailed Magnetic Resonance Imaging (MRI) examina- tions from 100,000 participants. The image data can be analyzed for example by auto- mated analysis with neural networks for image segmentation or classification to expand the collection of image-derived phenotypes for medical research. In this work, we pro- pose, present and evaluate a methodology that uses image-based regression to estimate numerical properties from the collected neck-to-knee water-fat MRI scans. It applies a ResNet50-style network to 2D multi-channel collages that represent targeted and study- specific anatomical sub-regions from the MRI scan. The targeted sub-region sampling is achieved by propagating manually defined subregions from a reference scan to the other >30,000 analyzed scans using image registration. The resulting collages can be compact while retaining high-resolution, for example by providing multiple slices of kidney tissue for a kidney volume regression network. This approach also enables group-wise saliency analysis that highlight image and anatomical regions used by the network for the pre- dictions. The method was applied for the regression endpoints of kidney volume, heart volume, and age. Predictive performance was found between R2 = 0.731-0.984 and the group-wise saliency maps were found to highlight medically relevant regions. We con- clude that the method can be used to standardize and restrict the information presented to a deep regression analysis pipeline, increasing information density and opening up a wide range of future medical inference studies.

Figures & tables

Explore similar work

Aug 23, 2026

Architectural and Regularization Components in Deep Learning Medical Image Registration: Systematic Ablation Study

Deep learning registration methods routinely stack two kinds of enhancement on a base network: architectural additions such as affine pre-alignment stages, and training-objective additions such as regularization losses. Papers tend to adopt both at once, so it is unclear which is doing the work. I ran a controlled ablation to separate them. Using the OASIS brain MRI dataset (394 training subjects, 20 test subjects), I trained four variants of the same registration pipeline: a baseline 3D U-Net with basic similarity losses, the same U-Net with a full regularization suite, an affine-plus-deformable architecture with basic losses, and the affine architecture with the full suite. I evaluated registration accuracy (MSE, NCC, SSIM), deformation quality (Jacobian determinant preservation, displacement statistics, an anatomical plausibility score), and computational cost. Regularization alone accounted for most of the gain: a 21.3% relative gain on the MSE-improvement metric (1.78% to 2.16%, P<.001) and a 21.8% relative gain in NCC improvement, while cutting maximum deformation from 53.1 to 0.51 units, a 99.0% reduction, at essentially no computational cost (-0.06% inference time). The combined model produced the largest accuracy gain, 25.8% (1.78% to 2.24%), and raised anatomical plausibility from 0.596 to 0.930, at a moderate +9.8% inference-time cost. Gradient correlation rose from 0.742 at baseline to 0.980 for the fully enhanced model. All enhanced variants reached sub-voxel accuracy under plausible deformation constraints. Regularization losses are the primary driver in this setting, delivering the accuracy gains and almost all of the deformation control for free at inference time, while the affine architecture adds a smaller complementary benefit at acceptable cost. The 99% reduction in unrealistic deformations addresses a known barrier to clinical deployment.
Jul 2, 2026

Population-Scale Segmentation of Penile Tissue in DIXON MRI using Deep Learning for Quantitative Phenotyping in Male Reproductive Health

Penile measurement is clinically relevant across male reproductive and urogenital health, including conditions such as micropenis, congenital and endocrine disorders, and sexual or urinary dysfunction. However, quantitative assessment of penile size has relied mainly on external length or circumference measurements, which are difficult to standardize, sensitive to measurement conditions, and unable to capture the internal portion of the penis. MRI enables volumetric assessment of the whole penis in vivo, but automated segmentation has not previously been established at population scale. Automated whole-organ volumetry would enable high-throughput phenotyping for multi-omics and clinical studies of male reproductive disease. Here, we present a deep learning framework for whole-penis segmentation in multi-channel DIXON MRI. Using a newly curated expert-annotated training dataset (n=145n = 145 subjects; 13,05013,050 annotated slices) and a double-annotated independent test benchmark (n=24n = 24 subjects; 2,1602,160 double-annotated slices), we optimized a 3D nnU-Net architecture. The model achieved a 5-fold cross-validation Dice score of 0.900.90 and performed at observer-level accuracy on the independent test set (Dice: 0.920.92; Hausdorff distance: 3.583.58). We deployed the model in 34,41234,412 UK Biobank participants, enabling automated quantification of total penile tissue, including both external and internal components. Longitudinal evaluation in 2,282 men demonstrated high inter-session reproducibility (r=0.87r = 0.87). This framework establishes a reproducible and population-scalable method for MRI-based assessment of penile anatomy and provides an open technical resource for future studies in urological imaging and male reproductive health. The trained model weights will be publicly released.
May 24, 2026

SpikeReg: Energy-Efficient 3D Deformable Medical Image Registration with Spiking Neural Networks

Deformable medical image registration aligns anatomical structures across images but remains computationally dense at 3D resolution. Spiking neural networks (SNNs) offer sparse event-driven computation, yet have not been systematically studied for deformable medical image registration. We introduce SpikeReg, a spiking U-Net for 3D brain MRI registration. SpikeReg is initialized from an analog ANN registration teacher, converted by layer-wise weight transfer and activation-percentile threshold calibration, and fine-tuned with a surrogate-gradient objective combining local cross-correlation, diffusion regularization, and spike-rate sparsity. On the OASIS Learn2Reg validation split (1919 image pairs), SpikeReg reaches Dice 0.7474±0.0320.7474 \pm 0.032, with no significant paired Dice difference from the ANN teacher (0.7480±0.0370.7480 \pm 0.037, p=0.67p = 0.67), at a 12.8%12.8\% mean spike rate and a 55.5×55.5\times projected arithmetic-energy reduction under an event-sparse SynOps/MAC proxy relative to the dense-ANN baseline. We additionally report two negative findings: displacement distillation from the ANN teacher hurts performance, and ANN teachers trained with a label-Dice loss fail to transfer through rate-code conversion. Together these results show that dense geometric prediction can be performed under sparse event-driven computation, opening a path toward neuromorphic medical image registration.